Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 10/Month |
Delivery Time | 7days |
Packaging Details | Aluminum alloy box |
Accuracy class | 0.05%, 0.1% |
Communication port | USB, RS232, RS485, LAN |
Frequency output | 45-65Hz |
Power factor output | -1 to 0 to +1 |
Phase output | 0°-359.999° |
Harmonic | 2 to 31 |
DC Voltage output | 75mV, 75 V, 150 V, 300 V, 500V, 1000 V |
DC Current output | 0.5 A,1A, 2.5 A, 5 A, 10A, 20 A |
DC Input Current Measurement | 0-20mA |
DC Input Voltage Measurement | 0 to ±20V |
Brand Name | GFUVE |
Model Number | GF3021 |
Certification | CNAS |
Place of Origin | China |
View Detail Information
Explore similar products
GFUVE T500HVD Non-contact Lightweight High Voltage Detector with Flashlight
Portable Electrical Test Equipment Three Phase Standard Meter English Display
GF333 Electronic Testing Tools Three Phase Standard Meter High Stability
High Accuracy Electronic Test Equipment , Reference Standard Meter Easy
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 10/Month |
Delivery Time | 7days | Packaging Details | Aluminum alloy box |
Accuracy class | 0.05%, 0.1% | Communication port | USB, RS232, RS485, LAN |
Frequency output | 45-65Hz | Power factor output | -1 to 0 to +1 |
Phase output | 0°-359.999° | Harmonic | 2 to 31 |
DC Voltage output | 75mV, 75 V, 150 V, 300 V, 500V, 1000 V | DC Current output | 0.5 A,1A, 2.5 A, 5 A, 10A, 20 A |
DC Input Current Measurement | 0-20mA | DC Input Voltage Measurement | 0 to ±20V |
Brand Name | GFUVE | Model Number | GF3021 |
Certification | CNAS | Place of Origin | China |
High Light | electronic test instruments ,electronic measurement equipment |
Portable Multi-function Instrument Calibrator GF3021 Electrical calibration
Electrical parameters | |
---|---|
Accuracy class | 0.05%, 0.1% |
Power supply | Single phase AC 220V±10% or 110V±10%, 50/60Hz |
Communication port | USB, RS232, RS485, LAN |
AC Voltage output | |
Range(U1,U2,U3) | 50V, 100V, 200V, 400V, 600V |
Adjustment range | (0 - 120)% RG |
Adjustment resolution | 0.01% RG, 0.1% RG, 1% RG, 10% RG |
Stability | 0.01% /1min |
Distortion | ≤0.2% (non-capacitive load) |
Max. output load | 25VA for each phase |
Accuracy | 0.05% RG |
AC Current output | |
Range(I1,I2,I3) | 0.5A, 1A, 2.5A, 5A, 10A, 20A |
Adjustment range | (0 - 120)% RG |
Adjustment resolution | 0.01% RG, 0.1% RG, 1% RG, 10% RG |
Stability | 0.01% /1min |
Distortion | ≤0.2% (non-capacitive load) |
Max. output load | 25VA for each phase |
Accuracy | 0.05% RG |
AC Power output | |
Active output stability | 0.01%RG/1min |
Reactive output stability | 0.02%RG/1min |
Active accuracy | 0.05% RG |
Reactive accuracy | 0.1% RG |
Frequency output | |
Adjustment range | 45-65Hz |
Adjustment resolution | 1Hz, 0.1Hz, 0.01Hz and 0.001Hz |
Resolution | 0.001Hz |
Accuracy | 0.002Hz |
Power factor output | |
Adjustment range | -1 to 0 to +1 |
Adjustment resolution | 0.0001 |
Resolution | 0.0005 |
Phase output | |
Adjustment range | 0°-359.999° |
Adjustment resolution | 10°, 1°, 0.1°, 0.01° |
Resolution | 0.001° |
Accuracy | 0.05° |
Harmonic configuration | |
Times | 2 to 31 |
Content | 0-40% |
Phase | 0°-359.999° |
Configuration error | (10% RD + 0.1%), RD refers to the configuration value of harmonic contents |
DC Voltage output | |
Range | 75mV, 75 V, 150 V, 300 V, 500V, 1000 V |
Adjustment range | (0-120)% RG |
Adjustment resolution | 0.01% RG, 0.1% RG, 1% RG, 10% RG |
Stability | 0.01% RG / 1 min |
Distorting | ≤0.2% (non-capacitive load) |
Output load | 25VA |
Accuracy | 0.05% RG |
Ripple contents | ≤1% |
DC Current output | |
Range | 0.5 A,1A, 2.5 A, 5 A, 10A, 20 A |
Adjustment range | (0-120)% RG |
Adjustment resolution | 0.01% RG, 0.1% RG, 1% RG, 10% RG |
Stability | 0.01% RG / 1min |
Distortion | ≤ 0.2% (non-capacitive load) |
Output load | 25VA |
Accuracy | 0.05% RG |
Ripple contents | ≤1% |
Energy Error | |
Active error | 0.05% RG |
Reactive error | 0.1% RG |
DC Input Voltage Measurement | |
Range | 0 to ±20V |
Measurement range | (0-120)% RG |
Accuracy | 0.01% RG |
Resolution | 0.001% RG |
DC Input Current Measurement | |
Range | 0-20mA |
Measurement range | (0-120)% RG |
Accuracy | 0.01% RG |
Resolution | 0.001% RG |
Mechanical parameters | |
Dimensions (W×H×D) (mm) | 460x430x185 |
Weight (kg) | 20 |
Environmental conditions | |
Working temperature | 0°C to 40°C |
Relative humidity | ≤85% |
Company Details
Business Type:
Manufacturer
Year Established:
2008
Total Annual:
$100,000,000-$150,000,000
Employee Number:
300~350
Ecer Certification:
Active Member
Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core... Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was established in 2008. It combined design, manufacturing and sales together as one high-tech enterprise. GFUVE Instrument Transformer company mainly produces less than 35kV current transformer and voltage transformer, split core...
Get in touch with us
Leave a Message, we will call you back quickly!