China factories

China factory - Shanghai Runpaiq Technology Co., Ltd.

Shanghai Runpaiq Technology Co., Ltd.

  • China,Shanghai ,Shanghai
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China 316L Electrode PTFE Liner Wastewater Flow Meter With Flanges Port
China 316L Electrode PTFE Liner Wastewater Flow Meter With Flanges Port

  1. China 316L Electrode PTFE Liner Wastewater Flow Meter With Flanges Port
  2. China 316L Electrode PTFE Liner Wastewater Flow Meter With Flanges Port

316L Electrode PTFE Liner Wastewater Flow Meter With Flanges Port

  1. MOQ: 1
  2. Price: USD280 (1-5 sets) / USD240 (>5 sets)
  3. Get Latest Price
Payment Terms T/T, L/C, D/A, D/P, Western Union
Supply Ability 2000 sets per month
Delivery Time 10-15 days
Packaging Details carton / wooden case
Accuracy 0.2%, 0.5%
Product name Electromagnetic flowmeter, HQLED electromagnetic flow meter with competitive price
Liquid media conductive liquid, water
Output 4-20 mA, Pulse, frequency
Communication Modbus RS485, bacnet, Mbus, GPRS
Medium temperature -20℃~+120℃, -20°C - +180 °C, ≤120℃, -40~180℃
Medium water, seawater, conductive fluid, liquid, conductivity >0.5μs/cm2
Usage heating system, HVAC, sewage, waste water, STP, ETP
Brand Name Runpaq
Model Number YF-E80-8
Certification CE, EXD
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C, D/A, D/P, Western Union Supply Ability 2000 sets per month
Delivery Time 10-15 days Packaging Details carton / wooden case
Accuracy 0.2%, 0.5% Product name Electromagnetic flowmeter, HQLED electromagnetic flow meter with competitive price
Liquid media conductive liquid, water Output 4-20 mA, Pulse, frequency
Communication Modbus RS485, bacnet, Mbus, GPRS Medium temperature -20℃~+120℃, -20°C - +180 °C, ≤120℃, -40~180℃
Medium water, seawater, conductive fluid, liquid, conductivity >0.5μs/cm2 Usage heating system, HVAC, sewage, waste water, STP, ETP
Brand Name Runpaq Model Number YF-E80-8
Certification CE, EXD Place of Origin China
High Light PTFE Liner Wastewater Flow Meter316L Electrode Wastewater Flow MeterFlanges Port Wastewater Flow Meter

mass flow meter for slurry, Electromagnetic Water Flow Meter electrode:316L, Liner: PTFE

 

Description

The YF series electromagnetic flow transmitter, with rugged, robust energy calculator that is ideal for commercial and industrial installations with a wide range of communication possibilities. It fulfils the IP67 requirements guarantee that the meter is resistant to dust, humidity and water, ensuring that no matter how hostile the conditions, the meter will continue accurately measuring.

The calculator can be read remotely using a wide variety of communication methods, some of which are in-built such as pulsed output and 4 analogue outputs.

It is a high end thermal energy calculator for industrial applications. Effectively protected against dust and humidity and backlit display. A wide range of built-in functions makes this energy meter a single box solution.

 

Measure theory

The electromagnetic flowmeters, can detect flow by using Faraday's Law of induction. Inside a magnetic flow meter, there is an electromagnetic coil, that generates a magnetic field, and the electrodes that capture electromotive force (voltage).

 

Features

  • Virtually no pressure loss
  • Suitable to meter for wide range of conductive liquid media
  • No Moving Parts
  • Flanges port connection
  • RS485 Standard
  • Suitable for Pipes diameter p to 2000 mm
  • Large meter ratio
  • High Accuracy
  • 4 to 20 mA / Frequency / Pulse output

Applications

  • MUNICIPAL WATER

  • INDUSTRIAL LIQUID

  • WASTEWATER

  • IRRIGATION

  • CHEMICALS

  • POWER SUPPLY

  • PHARMACEUTICALS

  • FOOD

  • PAPER PLANTS

  • METALLURGICAL MINES

Technical data

Product name Electromagnetic flowmeter
Product type Local|compact display Remote display Signal converter
Model IYF-E IYF-F IRT
Pipe Diameter (mm) DN10-DN2000
Power supply 100-240 VAC / 18-36 VDC
Accuracy + 0.5% + 0.5% + 0.5%
Power consumption <6w <6w <6w
Enclosure rating IP65 IP68 IP65
Liquid temperature -25-120℃ -25-120℃ -25-120℃
Ambient temperature -25-50℃ -25-50℃ -25-50℃
Relative humidity 10-90% 10-90% 10-90%
Meter ratio 1:100 1:100 1:100
Flow direction Bi-direction flow Bi-direction flow Bi-direction flow
Communication RS485 / Bacnet RS485 / Bacnet RS485 / Bacnet
Signal Output 4-20mA/Pulse/Frequency 4-20mA/Pulse/Frequency 4-20mA/Pulse/Frequency

 

Accuracy

Pipe Dia (mm) Velocity (m/s) Accuracy
3-20 <0.3 + 0.25% FS
0.3-1 + 1.0% Readout
1-15 + 0.25% Readout
25-600 0.1-0.3 + 0.25% FS
0.3-1 + 0.5% Readout
1-15 + 0.3% Readout
700-3000 <0.3 + 0.25% FS
0.3-1 + 1.0% Readout
1-15 + 0.25% Readout

 

 

 

 

 

 

 

 

 

 

 

 

Model selection

 

Notice on the selection of local type and remote type:

 

Remote type means the transmitter and converter display are mounted in different locations, it’s suggested to select
remote type in the following conditions:

  • Ambient temperature or converter display sunshine temperature is over 60 ℃
  • High humidity or corrosive air existed
  • Serious pipe vibration
  • Magnetic meter need be suspended or submersible, uneasily read out
  • Other abrasive condition
No Model              
  YF Electromagnetic flowmeter
  TF Turbine
  VF Votex
  LX Vane wheel
  T Ultrasonic
    E/F display mode E: compact/local display, F: remote display
      Pipe Dia Type (mm)
      xxxx

15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400,

500, 600, 800, 1000

      Code Accuracy
      1 + 0.5% FS
      2 + 1.0% FS
      3 + 0.2% FS
        Code Type
        N Converter: 12 / 24 VDC, pulse output
        A Transmitter: 24VDC, 4-20mA outpt
        B Intelligent, Lion battery, no local display
        G Smart, local display, 4-20mA output
        C1 Smart, local display, RS485
        C2 Smart, local display, HART
          Code Type
          S Carbon steel housing
          L Stainless steel housing
          G High pressure housing
          HL 316L electrode
          HTi Titanium electrode
          HTa Tantlum electrode
          HC Hastelloy-C electrode
          L1 Liquid media
          L2 Gas media
          P Pressure compensation
          T Temperature compensation
          PT Pressure&Temp. Compensation
          F PTFE liner
          X Rubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing,

smart, 4-20mA outpt, RS485, 316L electrodes, liquid media meter, PTFE liner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Applicable metering liquid:

  • Conductive liquid media, conductivity > 5 µS/ cm
  • Various Conductive aqueous solutions, water solutions, acid & caustics
  • Abrasive slurries, sludges and grease bearing liquids, corrosive liquid, municipal tap water, waste water,dirty
    water, effluent, fibrous, viscous, paper mill, food & beverage

Non-applicable metering medial

  • Industrial gas, compressed air, steam, or liquid with large content of gas
  • Liquid is non-conductive or low conductive, like lubricating oil, clean oil, cryogenic, cooling water, pure
    water, clean gas, etc.

Pipe Diameter, flow volume and product dimension

Dia Flow volume (m3/h) Product dimension (mm)
(mm) Normal Min Max L D H H1
15 1.5 0.06 9.5 150 95 272 254
20 2.5 0.11 16.9 105 277 254
25 3.5 0.18 26.5 115 283 254
32 6 0.29 43.6 140 297 270
40 10 0.45 67.8 150 307 280
50 15 0.71 106.0 200 165 318 294
65 25 1.19 179.1 185 337 313
80 40 1.81 271.4 200 352 326
100 60 2.83 424.1 250 220 371 344
125 100 4.42 665 250 401 372
150 135 6.36 954 300 285 431 403
200 250 11.3 1696 350 340 486 460
250 375 17.66 2650 400 395 547 511
300 540 25.43 3817 450 445 597 565
350 735 34.62 5195 505 657 620
400 960 45.22 6785 500 565 717 675
450 1200 57.23 8588 550 615 757 727
500 1500 70 10602 600 670 817 782
600 2160 100 15268 780 917 782
700 2950 138 20781 700 895 1027 1068
800 3850 180 27100 800 1015 1137 1157

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Industrial applications

Chemical Food & beverage Paper mill
Metallurgy Environment protection Hydraulic
Mining Stainless Petroleum
Pharmacy Air conditioner Effluent treatment plant
Seawater desalination Pharmacy Water treatment

 

 

 

 

 

 

 

Competitive advantage

  • Compliance to international standards: ISO14001, GB/T28001, ISO9001-2008 / GB/T50430
  • Strict process control
  • Advanced calibration equipment
  • Engineer team

Details demonstration

Inhouse PCB production Silicon steel transformer Calibration line

 

How to use the magnetic flow meter

The ElectroMagnetic flowmeters measure the velocity of conductive liquids in pipes, such as water, acids, caustic, and slurries. Magnetic flowmeters can measure properly when the electrical conductivity of the liquid is greater than approximately 5μS/cm. Be careful because using magnetic flowmeters on fluids with low conductivity, such as deionized water, boiler feed water, or hydrocarbons, can cause the flowmeter to turn off and measure zero flow.

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Agent

  • Year Established:

    2009

  • Total Annual:

    30000000-50000000

  • Employee Number:

    100~200

  • Ecer Certification:

    Active Member

We're a national key high-tech enterprise serving in fields of new energy management system and equipment, main services include: HVAC central air-conditioning and cold storage, solar distributed energy & regional energy, flow & energy management. We have integrative certification of ... We're a national key high-tech enterprise serving in fields of new energy management system and equipment, main services include: HVAC central air-conditioning and cold storage, solar distributed energy & regional energy, flow & energy management. We have integrative certification of ...

+ Read More

Get in touch with us

  • Reach Us
  • Shanghai Runpaiq Technology Co., Ltd.
  • Room E202, No. 4528 Jiasong Road (Middle), Qingpu district 201705, Shanghai, China
  • MrYuan
  • 008613816614405
  • https://www.zone-valve.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement