| Payment Terms | T/T |
| Supply Ability | 500 |
| Delivery Time | 21 days |
| Packaging Details | 37x26x5 cm |
| Product Name | Online COD Sensor Iot |
| Power Supply | 12-24V DC |
| Working Conditions | 0~45℃,≤0.2MPa |
| Measuring Principle | Dual wavelength UV absorption method |
| Minimum Detectability | 0.2mg/L(0-200mg/L);0.4mg/L(0-500mg/L) |
| Temperature Compensation | Automatic temperature compensation (Pt1000) |
| Electrode usage cycle | 18 months |
| Frequency | CN470/IN865/EU868/RU864/US915/AU915/ KR920/AS923-1&2&3&4 |
| Mode | OTAA Class A/C |
| Reporting cycle | 10min(Default reporting cycle) |
| Communication Protocol | LoRaWAN |
| MAC Version | LoRaWAN 1.0.3 |
| Brand Name | ZONEWU |
| Model Number | LW106D-COD |
| Certification | CE/RoHS |
| Place of Origin | Xiamen |
View Detail Information
Explore similar products
Industrial LoRa CH4 Temperature & Humidity Sensor Long Distance Wireless Gas
ZONEWU LoRaWAN Online Turbidity Sensor – IP68 Self-Clean for Fish Pond & Rural
LoRaWAN Wireless Ammonia Nitrogen Sensor, Suitable for Online Monitoring of
LoRaWAN Oxygen Temperature and Humidity Sensor | Oxygen Concentration Monitoring
Product Specification
| Payment Terms | T/T | Supply Ability | 500 |
| Delivery Time | 21 days | Packaging Details | 37x26x5 cm |
| Product Name | Online COD Sensor Iot | Power Supply | 12-24V DC |
| Working Conditions | 0~45℃,≤0.2MPa | Measuring Principle | Dual wavelength UV absorption method |
| Minimum Detectability | 0.2mg/L(0-200mg/L);0.4mg/L(0-500mg/L) | Temperature Compensation | Automatic temperature compensation (Pt1000) |
| Electrode usage cycle | 18 months | Frequency | CN470/IN865/EU868/RU864/US915/AU915/ KR920/AS923-1&2&3&4 |
| Mode | OTAA Class A/C | Reporting cycle | 10min(Default reporting cycle) |
| Communication Protocol | LoRaWAN | MAC Version | LoRaWAN 1.0.3 |
| Brand Name | ZONEWU | Model Number | LW106D-COD |
| Certification | CE/RoHS | Place of Origin | Xiamen |
The LW106D LoRaWAN Water Quality COD Sensor is an integrated online water quality detection device, which comes with a full set of accessories including a sensor collector, a COD transmitter and a TYPE-C data cable. It adopts the reagent-free dual-wavelength ultraviolet absorption method for COD detection, and integrates the three-parameter detection function of COD, turbidity and temperature. Built-in with a self-cleaning system and a Pt1000 temperature transmitter, it can realize automatic temperature compensation and turbidity interference compensation. Complying with the LoRaWAN 1.0.3 standard protocol and compatible with multi-regional frequency bands worldwide, the device operates in OTAA Class C mode. With an industrial-grade design, it can adapt to the working environment of 0~45℃ and ≤0.2MPa, and is powered by a rated 12VDC wide voltage. The electrode has a service life of 18 months, the transmitter cable supports customization, and the device features both local configuration and remote control functions, making it suitable for various water quality monitoring scenarios.
1. Core Features
It is equipped with three ranges for COD detection with a unified resolution of 0.1, adapting to the detection needs of different water quality concentrations; the modulated optical signal technology reduces visible light interference and ensures high detection accuracy; the built-in self-cleaning system reduces manual maintenance work. The sensor supports remote calibration, parameter configuration and firmware upgrade, can accurately identify abnormal sensor data, and its reporting cycle is flexibly customizable.
2. Core Technologies
It is equipped with dual-wavelength ultraviolet absorption detection technology and Pt1000 platinum resistor temperature compensation technology; adopts LoRa wireless communication and anti-interference optical technology, and is matched with RS485 and TYPE-C interfaces to achieve stable data interaction; supports online firmware upgrade, and the uplink and downlink data are transmitted in a standardized hexadecimal format.
3. Detection Principle
It realizes reagent-free COD detection based on the dual-wavelength ultraviolet absorption method, and corrects detection errors through integrated turbidity detection and temperature compensation, and filters out visible light interference via modulated optical signals; it completes wireless networking and data transmission in compliance with the LoRaWAN protocol. The self-cleaning system regularly cleans the detection window through its mechanical structure to prevent biological adhesion.
4. Application Scenarios
It can be used for the monitoring of municipal drinking water and surface water such as rivers and lakes, meeting the requirements of national water quality testing standards; it is suitable for industrial circulating water systems and sewage discharge scenarios to timely monitor water quality deterioration and discharge compliance; as a terminal sensing device for smart water conservancy, it enables unmanned remote intelligent monitoring of outdoor and remote water environments.
|
Power Specifications
|
Rated Voltage:12VDC,Scope:DC10~28V | |
| Rated input current: 500mA | ||
|
Interface specification: DC 5.5mm × 2.1mm (positive inside and negative outside) |
||
| Working Conditions | 0~45℃,≤0.2MPa | |
| Measuring Principle | Dual wavelength UV absorption method | |
| Range and Resolution |
0~200.0 mg/L 0~200.0 NTU |
0.1 |
|
0~500.0 mg/L 0~400.0 NTU |
||
|
0~1500.0 mg/L 0~1000.0 NTU |
||
| Accuracy |
0~200.0 mg/L 0~200.0 NTU |
±5%;±0.3℃ |
|
0~500.0 mg/L 0~200.0 NTU |
||
|
0~1500.0 mg/L 0~1000.0 NTU |
0~1000: ±10%, 1000~1500:±5%;±0.3℃ |
|
| Minimum Detectability | 0.2mg/L(0-200mg/L) | |
| 0.4mg/L(0-500mg/L) | ||
| Temperature Compensation | Automatic temperature compensation (Pt1000) | |
| Electrode usage cycle | 18 months | |
| Transmitter Line length | Default 5m (other lengths can be customized) | |
| Frequency |
CN470/IN865/EU868/RU864/US915/AU915/ KR920/AS923-1&2&3&4 |
|
| Mode | OTAA Class C | |
| Reporting cycle | 10min(Default ) | |
| Communication Protocol | LoRaWAN,LoRa TDMA Networking | |
|
Equipment information (Reference) |
AppEUI:331341E186891989 DevEUI:aaaa202404150001 AppKey:5572404c696e6b4c6f52613230313823 MAC Version:LoRaWAN 1.0.3 |
|
Single gross weight: 1.200 KG
Single package size: 37X26X5 cm
![]()
![]()
Application:
From municipal water supply networks to commercial swimming pool aquaculture, and even industrial sewage treatment, this LoRa residual chlorine sensor enables real-time wireless monitoring to accurately control the residual chlorine concentration in water bodies across various scenarios, comprehensively ensuring the safety of drinking water, compliance of commercial water quality, and stability of industrial treatment processes.
![]()
1.Are you manufacture?
A:Yes,we are Tranmitter manufacturer and exporter in China with more than 10 years of CE,ROHS,FCC,ISO and 11 patents experience.
2.Do you offer OEM services?
A:Yes,we can provide you with OEM services and design housings and logos.
3.DO you offer free samples?
A:Sorry,we don't offer free samples.After ordering in bulk,we will deduct the sample fee from the second order.
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2017
Employee Number:
5~50
Ecer Certification:
Site Member
ZONEWU is a professional provider of LoRaWAN IoT sensors and wireless sensing solutions. We focus on industrial-grade, low-power, long-range sensors for smart industry, agriculture, environment and smart city. We deliver reliable products and customized services to global system integrators and clie... ZONEWU is a professional provider of LoRaWAN IoT sensors and wireless sensing solutions. We focus on industrial-grade, low-power, long-range sensors for smart industry, agriculture, environment and smart city. We deliver reliable products and customized services to global system integrators and clie...
Get in touch with us
Leave a Message, we will call you back quickly!