China factories

Chat Now Send Email
China factory - Shenzhen Jutai Comm Co., Ltd.

Shenzhen Jutai Comm Co., Ltd.

  • China,Shenzhen ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Dual Loop Vehicle Sensor for Parking Barrier Gate with High Sensitivity Truck
China Dual Loop Vehicle Sensor for Parking Barrier Gate with High Sensitivity Truck

  1. China Dual Loop Vehicle Sensor for Parking Barrier Gate with High Sensitivity Truck

Dual Loop Vehicle Sensor for Parking Barrier Gate with High Sensitivity Truck

  1. MOQ: 1
  2. Price: Negotiation
  3. Get Latest Price
Self-Turning Range 20-2000uh
Sensitivity 16-Way Selectable/ Highest 0.010%Dl/L/Lowest 2.56%
Power Requirements 12-24V
Specification 13.6*8.6*5.2
Response Times Turn-on 10-90ms/Turn-off 10-90ms
Operation Temp -40 ~ +70℃
Payment Terms T/T,L/C,D/A,D/P,Western Union,Paypal,MoneyGram,Alipay
Supply Ability 1000 pieces per month
Delivery Time 5 - 8 working days
Packaging Details Carton
Brand Name JUTAI
Model Number LD-202
Certification CE
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Self-Turning Range 20-2000uh Sensitivity 16-Way Selectable/ Highest 0.010%Dl/L/Lowest 2.56%
Power Requirements 12-24V Specification 13.6*8.6*5.2
Response Times Turn-on 10-90ms/Turn-off 10-90ms Operation Temp -40 ~ +70℃
Payment Terms T/T,L/C,D/A,D/P,Western Union,Paypal,MoneyGram,Alipay Supply Ability 1000 pieces per month
Delivery Time 5 - 8 working days Packaging Details Carton
Brand Name JUTAI Model Number LD-202
Certification CE Place of Origin China
High Light dual loop vehicle sensorparking barrier gate sensorhigh sensitivity truck detector
Dual Loop Vehicle Sensor for Parking Barrier Gate with High Sensitivity Truck Detection
JUTAI dual-loop vehicle sensor is engineered for parking barrier gate systems, providing high-precision vehicle detection for cars, vans, and large trucks. With two independent detection channels, it ensures reliable vehicle presence sensing for automatic gate control, traffic management, and secure access systems.
JUTAI Double Channel Car Parking Management Inductive Loop Detector
Common Applications of Inductive Loop Sensors
  • Parking Management
  • Toll Booths & Highways
  • Gated Communities & Residential Areas
  • Commercial Buildings & Offices
  • Airports & Transport Hubs
  • Industrial & Warehouse Facilities
  • Event & Stadium Parking
  • Smart City Traffic Systems
  • Fleet & Logistics Centers
  • Bus & Transit Terminals
Key Features
Dual-Channel Detection
Independent vehicle sensing (CH1 & CH2)
High Sensitivity
Detects trucks, buses, and heavy vehicles
Adjustable Sensitivity & Frequency
Optimized for different loop setups
Relay Output
Directly controls barrier gates & access systems
LED Status Indicators
Power, detection, and loop status
Easy Loop Installation
Works with road-embedded inductive loops
Technical Specifications
Feature Details
Power Supply 100-240V AC (LD-200) / 12-24V DC (LD-202)
Detection Method Inductive Loop (地感)
Channels 2 (CH1 & CH2)
Output Relay (NO/COM)
Vehicle Types Cars, Trucks, Trailers
Sensitivity 8-Level Adjustment (0.015%-0.8%)
Frequency 20KHz-100KHz (Adjustable)
LED Indicators Power (Red), Detection (Green)
Loop Wires CH1 (Pin 3,4), CH2 (Pin 5,6)
Relay Contacts CH1 (Pin 10,11), CH2 (Pin 7,8)
Why Choose JUTAI Sensor?
  • Best for Parking Barriers - Ensures no false triggers
  • Truck & Heavy Vehicle Compatible - No missed detections
  • Customizable Sensitivity - Works in different road conditions
  • Durable & Weatherproof - Suitable for outdoor installations
Connections
JUTAI Loop Detector Connection Diagram
Indicators and Switches
  • Power LED (RED): Illuminates to indicate "Power ON."
  • CH1 Detection LED:
    • Steady On: Indicates vehicle detection
    • Slow Blinking: Indicates a loop short circuit or insufficient twists after the loop
    • Fast Blinking: Indicates a loop open circuit or excessive twists after the loop
  • CH2 Detection LED:
    • Steady On: Indicates vehicle detection
    • Slow Blinking: Indicates a loop short circuit or insufficient twists after the loop
    • Fast Blinking: Indicates a loop open circuit or excessive twists after the loop
Sensitivity Selection
Sensitivity and frequency adjustment is facilitated through a 7-way dip switch and 10-way dip switch settings. Users can choose from 8 different sensitivity settings by configuring the dip switch positions according to the provided tables.
  • Dip switches 6, 7, and 8 govern CH1 sensitivity, ranging from 0.8 (least sensitive) to 0.015 (most sensitive)
  • Dip switches 3, 4, and 5 control CH2 sensitivity, ranging from 0.8 (least sensitive) to 0.015 (most sensitive)
JUTAI Loop Detector Switch Configuration
Switch 1 (S1): Channel 1 Loop Function Selection
Special Sensitivity Increase For Both Trailer (Both Channels)
Special Sensitivity Increase Configuration
Special Functions Setting (Direction Detection Modes)
Direction Detection Mode Settings
CH1 and CH2 Sensitivity Selection
Sensitivity Selection Settings
Frequency Settings (20 K to 100 KHz)
Frequency Settings Configuration
Reset Button: Please note: The LD-200 must be reset every time a setting change is made to the Dip switches.
Installation Precautions and Troubleshooting
  • Coil Cutting Size and Embedding Guidelines are as shown in the diagram on the right
  • It is recommended to use ferromagnetic wires for the induction coil, with a total length of up to 500 meters
  • The cutting size of the coil should be a rectangle with a length of 1.0 to 2.0 meters and a width of 0.8 to 1.2 meters, avoiding right angles at corners as much as possible
Recommended Installation Overview
Basic Typical Coil Turns Installation Diagram
When installing, please keep the product plug and socket in the vertical direction
Proper Installation Orientation
Application
The JUTAI LD200/202 double-channel vehicle loop detector series, equipped with direction recognition function, is ideal for numerous single-channel entry and exit scenarios. When integrated with the JUTAI One door controller (Model: AC-11), JUTAI gate barrier (Model: BR-110), and JUTAI long-range RFID reader (Model: PUHF-9), along with high-temperature resistance loop coils (Model: JTHT-11), it forms a seamless solution for single-channel entry/exit access control systems.
JUTAI Access Control System Integration
Working Principle
Entry Process:
  • When a car enters the community or parking lot, the two loop coils are pressed simultaneously
  • The JUTAI Double Channel Loop Detector (LD-200/202) triggers the UHF reader located at the entrance
  • The UHF reader reads the card ID and sends it to the controller (AC-11) via Wiegand output
  • The controller verifies the ID's validity and outputs a relay signal to open the gate barrier
  • The car enters the community or parking lot, and as it passes the barrier gate, the barrier arm lowers automatically
  • The JUTAI Single Channel Loop Detector (LD-100/102) ensures safety and anti-smashing functionality during this process
Exit Process:
  • When a car exits the community or parking lot, it passes by an inside UHF reader
  • The LD-200/LD-202 triggers the UHF reader, which reads the card and sends the ID to the controller
  • The controller verifies the ID's validity and outputs a relay signal to open the gate barrier for the car to exit
  • As the car passes through the barrier gate, the barrier arm lowers automatically
  • The LD-100/102 provides safety and anti-smashing functionality during this process
Direction Recognition:
  • The Direction Recognition Function of LD-200/LD-202 ensures that the double channels loop detector does not trigger the signal again when the car passes another UHF reader, thereby recording only the entry or exit records in the system
Direction Recognition System Diagram
The JUTAI LD-200/202 Double Channel Loop Detector can also function as two independent single-channel loop detectors. This configuration is suitable for standard one-in and one-out parking lots, where there is one barrier and one long-range reader at both the entrance and exit.
In this setup, one loop coil is used to trigger the reader and read the card, while the other loop coil is dedicated to the barrier's anti-smashing function. By utilizing the LD-200/202 as two independent loop detectors, there is a potential cost-saving benefit from an economic standpoint. This setup reduces some of the hardware costs associated with using separate detectors for each function.
This functionality is achieved by enabling the Independent Working Mode feature of the LD-200/202, allowing it to operate effectively in this dual capacity.
Independent Working Mode Configuration JUTAI Loop Detector Additional View JUTAI Loop Detector Installation Example

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2012

  • Total Annual:

    120000-150000

  • Employee Number:

    50~70

  • Ecer Certification:

    Verified Supplier

Shenzhen Jutai COMM Co., Ltd. is a high-tech privately-owned enterprise that integrates production, research and development, and sales. Our company is dedicated to the research and development as well as system integration of security products, achieving an intelligent one unified platform that int... Shenzhen Jutai COMM Co., Ltd. is a high-tech privately-owned enterprise that integrates production, research and development, and sales. Our company is dedicated to the research and development as well as system integration of security products, achieving an intelligent one unified platform that int...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Jutai Comm Co., Ltd.
  • 5f, Xuxingda Industrial Park, Shiyan, Baoan, Shenzhen, Guangdong, China
  • https://www.accesssecuritysolution.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement