Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"LD-200 Two Channel Parking Loop Detector with Direction Recognition Presence and","imgUrl":"https:\/\/img.chinax.com\/nimg\/27\/02\/c413d0169d94f147dd80ce5c5733-200x200-1\/ld_200_two_channel_parking_loop_detector_with_direction_recognition_presence_and.jpg","attrs":{"Detection Channels":"2 Channels","Frequency Steps":"4","Payment Terms":"T\/T,L\/C,D\/A,D\/P,Western Union,Paypal,Alipay","Direction Detection":"Supported"}}
{"title":"Gate Loop Detector for Barrier Industrial Doors Loop Short Open Circuit","imgUrl":"https:\/\/img.chinax.com\/nimg\/c4\/13\/87e5cdc3cda4d5ea44a30a28136b-200x200-1\/gate_loop_detector_for_barrier_industrial_doors_loop_short_open_circuit_indicator_reliable_performance.jpg","attrs":{"Sensitivity":"20-2000\u03bcH","Fault Output":"Blinks slowly: may indicate a short circuit or insufficient number of turns Blinks faster: may indicate an open loop or excessive number of turns","Relay":"Presence relay \/ Fault relay","Sensory regulation":"6 way selectable\/Highest0.010%DL\/L\/ Lowest 2.56%DL\/L"}}
{"title":"LD-200 Vehicle Direction Loop Detector with Dual Independent Channels for","imgUrl":"https:\/\/img.chinax.com\/nimg\/77\/80\/3b3f43b3f08a9bded5c777adb906-200x200-1\/ld_200_vehicle_direction_loop_detector_with_dual_independent_channels_for_parking_entrance_and_exit_control.jpg","attrs":{"Model Number":"LD-200","Auto Reset Time":"10 Minutes in Normal Mode","Certification":"CE","Detection Channels":"2 Channels"}}
{"title":"LD-100 Single Channel Vehicle Loop Detector with 16 Sensitivity Levels, 20","imgUrl":"https:\/\/img.chinax.com\/nimg\/53\/c6\/58adbce623a4521f4259d556e351-200x200-1\/ld_100_single_channel_vehicle_loop_detector_with_16_sensitivity_levels_2c_20_2000uh_range_and_automatic_reset_for_parking_barrier_.jpg","attrs":{"Brand Name":"JUTAI","Frequency Levels":"High \/ Medium-High \/ Medium-Low \/ Low","Delivery Time":"3-7 Working Days","Detection Technology":"Inductive Loop Vehicle Detection"}}
LD-200 Two Channel Parking Loop Detector with Direction Recognition
Product Overview
The LD-200 combines two parking-loop inputs with configurable relay logic for presence, pulse, and vehicle-direction applications. This detector is designed for barrier gates and parking-control cabinets where CH1 and CH2 require monitoring by a single device with different output behavior based on lane sequence.
The relay configuration is a key strength of this product. In independent mode, both channels function as separate vehicle-presence detectors. In pulse modes, the corresponding relay produces output when vehicles enter or leave loops. In directional modes, the detector uses CH1 and CH2 activation sequence to determine travel direction and generate programmed relay responses.
This makes the LD-200 ideal for installers needing one dual-channel detector to cover multiple parking functions instead of selecting different detectors for various lane designs.
Key Features
CH1 and CH2 inductive loop inputs
Presence relay operation
Pulse relay operation
Vehicle direction recognition
Six selectable working modes
Eight sensitivity settings per channel
20-100kHz adjustable frequency
Permanent vehicle presence mode
Approximately 10-minute automatic reset
LED indication for loop status and faults
Technical Specifications
Parameter
Specification
Model
LD-200
Primary Use
Parking barrier dual-loop detection
Number of Detection Zones
2
Loop Inputs
CH1 + CH2
Power
100-240VAC
CH1 Relay
COM / NO
CH2 Relay
COM / NO
Direction Detection
Configurable
Presence Mode
Configurable
Pulse Mode
Configurable
Selectable Modes
6
Sensitivity Levels
8 each channel
Sensitivity Range
0.015%-0.8%
Frequency
20-100kHz
Frequency Steps
4
Auto Reset
Approx. 10 min in normal mode
Permanent Presence
Available
Trailer Mode
Sensitivity increase available
Typical Applications
Barrier opening request
Vehicle presence monitoring
Passage confirmation
Entry/exit direction logic
Two-zone detection
Vehicle-flow signal generation
Loop Layout and Connection
For directional detection, two separate loops are aligned with the vehicle path and spaced approximately 1 meter apart. Loop turns are selected according to total loop perimeter. Installers should verify both loops separately, select suitable sensitivity, and choose different frequency settings when nearby loops create interference.
Indicators and Status
Power LED (RED): Illuminates to indicate "Power ON"
CH1 Detection LED:
Steady On: Vehicle detection
Slow Blinking: Loop short circuit or insufficient twists
Fast Blinking: Loop open circuit or excessive twists
CH2 Detection LED:
Steady On: Vehicle detection
Slow Blinking: Loop short circuit or insufficient twists
Fast Blinking: Loop open circuit or excessive twists
Sensitivity Configuration
Sensitivity and frequency adjustment is facilitated through 7-way and 10-way dip switch settings:
8 different sensitivity settings available via dip switch configuration
Dip switches 6, 7, and 8 govern CH1 sensitivity (0.8 to 0.015)
Dip switches 3, 4, and 5 control CH2 sensitivity (0.8 to 0.015)
Switch Configuration
Switch 1 (S1) - Channel 1 Loop Function Selection:
DIP 1 & DIP 2: Special Sensitivity Increase For Both Trailer (Both Channels)
D3, D4, D5 and Switch 2 D1, D2: Special Functions (Mode1, 2, 3 Direction Detection. Mode 4, 5, 6 Normal mode)
D6 & D7 & D8 and Switch 2 D3 & D4 & D5: CH1 and CH2 Sensitivity Selection (Eight Levels)
D9 & D10 and Switch2 D6, D7: Frequency Selection (20 K to 100 KHz)
Reset Button Note: The LD-200 must be reset every time a setting change is made to the Dip switches.
Installation Guidelines
Coil cutting size should be rectangle: length 1.0 to 2.0 meters, width 0.8 to 1.2 meters
Avoid right angles at corners as much as possible
Use ferromagnetic wires for induction coil, total length up to 500 meters
Keep product plug and socket in vertical direction during installation
System Integration
The JUTAI LD200/202 double-channel vehicle loop detector series, equipped with direction recognition function, is ideal for single-channel entry and exit scenarios when integrated with:
Car enters community/parking lot, pressing two loop coils simultaneously
LD-200/202 triggers UHF reader at entrance
UHF reader reads card ID and sends to controller via Wiegand output
Controller verifies ID validity and outputs relay signal to open gate barrier
Car enters, barrier arm lowers automatically
LD-100/102 provides safety and anti-smashing functionality
Exit Process
Car exits community/parking lot, passing inside UHF reader
LD-200/LD-202 triggers UHF reader to read card and send ID to controller
Controller verifies ID validity and outputs relay signal to open gate barrier
Car exits, barrier arm lowers automatically
LD-100/102 provides safety and anti-smashing functionality
Direction Recognition: The Direction Recognition Function ensures the double channels loop detector does not trigger the signal again when the car passes another UHF reader, recording only entry or exit records in the system.
Independent Operation Mode
The JUTAI LD-200/202 Double Channel Loop Detector can also function as two independent single-channel loop detectors, suitable for standard one-in and one-out parking lots. This configuration provides cost-saving benefits by reducing hardware costs associated with using separate detectors for each function.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter
Year Established:
2012
Total Annual:
120000-150000
Employee Number:
50~70
Ecer Certification:
Verified Supplier
Shenzhen Jutai COMM Co., Ltd. is a high-tech privately-owned enterprise that integrates production, research and development, and sales. Our company is dedicated to the research and development as well as system integration of security products, achieving an intelligent one unified platform that int... Shenzhen Jutai COMM Co., Ltd. is a high-tech privately-owned enterprise that integrates production, research and development, and sales. Our company is dedicated to the research and development as well as system integration of security products, achieving an intelligent one unified platform that int...