LD-200 Double Channel Loop Sensor For Parking Barrier Access Vehicle Detector

  1. MOQ: 1
  2. Price: Negotiation
  3. Get Latest Price
Sensitivity 20-2000μH
Specification 13.6*8.6*5.2mm
Sensitivity Setting 16-Way Selectable/ Highest 0.010%Dl/L/Lowest 2.56%
Power 110-240VAC (48 to 63Hz)
Response Times Turn-on 10-90ms/Turn-off 10-90ms
Operation Temp -40 ~ +70℃
Payment Terms T/T,L/C,D/A,D/P,Western Union,Paypal,MoneyGram,Alipay
Supply Ability 1000 pieces per month
Delivery Time 5 - 8 working days
Packaging Details Cartoon
Brand Name JUTAI
Model Number LD-200
Certification CE
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Sensitivity 20-2000μH Specification 13.6*8.6*5.2mm
Sensitivity Setting 16-Way Selectable/ Highest 0.010%Dl/L/Lowest 2.56% Power 110-240VAC (48 to 63Hz)
Response Times Turn-on 10-90ms/Turn-off 10-90ms Operation Temp -40 ~ +70℃
Payment Terms T/T,L/C,D/A,D/P,Western Union,Paypal,MoneyGram,Alipay Supply Ability 1000 pieces per month
Delivery Time 5 - 8 working days Packaging Details Cartoon
Brand Name JUTAI Model Number LD-200
Certification CE Place of Origin China
High Light Parking Barrier Access Loop SensorLD-200 Double Channel Loop SensorVehicle Detector Loop Sensor
LD-200 Double Channel Loop Sensor For Parking Barrier Access Vehicle Detector
Product Overview
Double Channel Car Parking Management Inductive Loop Detector

The JUTAI Dual Channels Traffic Detector (LD-200/202) is engineered for precise vehicle detection and reliable traffic monitoring in parking and access control systems.

Key Features
  • Dual independent detection channels (CH1 and CH2)
  • Comprehensive diagnostic indicators for power and loop status
  • Adjustable sensitivity and frequency via dip switches
  • Multiple operational modes including direction detection
  • Reset functionality for configuration changes
  • Compact, well-engineered housing design
  • Selectable presence time up to 30 minutes
  • Loop frequency interference indication
  • Direction detection capability
  • Automatic Sensitivity Boost (ABS)
Technical Specifications
Specification Details
Loop Inductance 20-2000μH
Sensitivity 8-way selectable
Highest: 0.015% DL/L
Lowest: 0.8% DL/L
Frequency Four-step switch selectable: 20-80KHz
Power Requirements 110-240VAC (48 to 62Hz)
12-24VADC (48 to 62Hz)
Operation Temperature -40℃ to +70℃ (-111℉ to +158℉)
Response Times 10-90MS
Size 75mm x 43mm x 110mm
Humidity Up to 95% relative humidity without condensation
Loop Detector specifications diagram
Modes of Operation
  • Presence Mode
  • Pulse Mode
  • AB Logic Presence Mode (Barrier Operation)
  • AB Logic Pulse Mode (Counting Logic)
Multi-type voltage vehicle loop detection sensors
Applications
  • Automatic Gate Systems
  • Traffic Light Control
  • Gate Drive Mechanisms
  • Operating Barriers
  • Parking Guidance Systems
  • Activating Card Dispensers in Parking Lots
  • Parking Barrier Control
  • Vehicle Access Control
  • Traffic Control & Toll Systems
  • Vehicle Counting Systems
  • Motorised Gates and Doors
  • Security Bollards/Rolling Shutters/Garage Doors
  • Camera Trigger Systems
Installation & Configuration
Double Channel Loop Detector connections diagram
Indicator Functions
  • Power LED (RED): Indicates "Power ON" status
  • CH1 Detecting LED:
    • Continuously On: Vehicle detection active
    • Blinking slowly: Loop short circuit or insufficient twists
    • Blinking fast: Loop open circuit or excessive twists
  • CH2 Detecting LED:
    • Continuously On: Vehicle detection active
    • Blinking slowly: Loop short circuit or insufficient twists
    • Blinking fast: Loop open circuit or excessive twists
Sensitivity Selection

Sensitivity and frequency adjustment is achieved through 7-way and 10-way dip switch settings with 8 different sensitivity levels available.

Loop detector switch configuration Special sensitivity increase settings Direction detection mode settings Sensitivity selection settings Frequency selection settings
Reset Requirement: The LD-200 must be reset every time a setting change is made to the Dip switches.
Installation Guidelines
  • Coil cutting size: Rectangle 1.0-2.0m length × 0.8-1.2m width
  • Avoid right angles at corners during installation
  • Use ferromagnetic wires with total length up to 500 meters
  • Keep product plug and socket in vertical direction during installation
Coil installation overview and typical turns Proper installation orientation
Working Principle
Entry Process Exit Process
  1. Both loop coils detect vehicle entry
  2. LD-200/202 triggers UHF reader at entrance
  3. UHF reader sends ID to controller (AC-11)
  4. Controller outputs relay signal to open gate barrier
  5. Vehicle enters and barrier lowers automatically
  6. LD-100/102 ensures safety and anti-smashing functionality
  1. Vehicle passes inside UHF reader during exit
  2. LD-200/202 triggers UHF reader to read card ID
  3. Controller verifies ID validity and opens gate barrier
  4. Vehicle exits and barrier lowers automatically
  5. LD-100/102 provides safety and anti-smashing functionality
Direction Recognition

The Direction Recognition Function prevents duplicate triggering when vehicles pass additional UHF readers, ensuring accurate entry/exit record keeping.

System Integration

Compatible with JUTAI door controller (AC-11), gate barrier (BR-110), long-range RFID reader (PUHF-9), and high-temperature resistance loop coils (JTHT-11) for comprehensive access control solutions.

Independent Operation Mode

LD-200/202 can function as two independent single-channel loop detectors, ideal for standard one-in/one-out parking lots while reducing hardware costs.

Troubleshooting Guide
Symptoms Solution
Detector not working Press reset button
Red LED indicator not fully lit Check power supply connection
Green LED blinking slowly Possible loop short circuit or insufficient turns
Green LED blinking faster Possible loop open circuit or excessive turns
Insufficient number of turns Lower frequency (add more turns if frequency still too high)
Excessive number of turns Higher frequency (remove some turns if frequency still too low)
Troubleshooting diagram 1 Troubleshooting diagram 2 Troubleshooting diagram 3 Additional technical diagram Installation reference diagram

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2012

  • Total Annual:

    120000-150000

  • Employee Number:

    50~70

  • Ecer Certification:

    Verified Supplier

Shenzhen Jutai COMM Co., Ltd. is a high-tech privately-owned enterprise that integrates production, research and development, and sales. Our company is dedicated to the research and development as well as system integration of security products, achieving an intelligent one unified platform that int... Shenzhen Jutai COMM Co., Ltd. is a high-tech privately-owned enterprise that integrates production, research and development, and sales. Our company is dedicated to the research and development as well as system integration of security products, achieving an intelligent one unified platform that int...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Jutai Comm Co., Ltd.
  • 5f, Xuxingda Industrial Park, Shiyan, Baoan, Shenzhen, Guangdong, China
  • https://www.accesssecuritysolution.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement