Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"110-240V Single Channel Boom Barrier Loop Sensor LD-100 Vehicle Detector","imgUrl":"https:\/\/img.chinax.com\/nimg\/e0\/c2\/e19b001ecd9f09f9430b046e0455-200x200-1\/110_240v_single_channel_boom_barrier_loop_sensor_ld_100_vehicle_detector.jpg","attrs":{"Brand Name":"JUTAI","Model Number":"LD-100","Certification":"CE","Place of Origin":"China"}}
{"title":"110-240V Single Channel Boom Barrier Loop Detector 40000V Lightning Protection","imgUrl":"https:\/\/img.chinax.com\/nimg\/ed\/c9\/939f5dc0a45c7e5051123ca7283f-200x200-1\/110_240v_single_channel_boom_barrier_loop_detector_40000v_lightning_protection.jpg","attrs":{"Brand Name":"JUTAI","Model Number":"LD-100","Certification":"CE","Place of Origin":"China"}}
{"title":"Four Step Switch Selectable 20-80KHz Loop Detector For Gate Barrier","imgUrl":"https:\/\/img.chinax.com\/nimg\/71\/3a\/a3997f9b551df497f5e335e77d94-200x200-1\/four_step_switch_selectable_20_80khz_loop_detector_for_gate_barrier.jpg","attrs":{"Brand Name":"JUTAI","Model Number":"LD-100","Certification":"CE","Place of Origin":"China"}}
{"title":"Loop Detectors For Automated Gates 20-2000uH Lightning Protection Auto Reset","imgUrl":"https:\/\/img.chinax.com\/nimg\/a9\/08\/44a98a16779fb7f3f360fc47092d-200x200-1\/loop_detectors_for_automated_gates_20_2000uh_lightning_protection_auto_reset.jpg","attrs":{"Brand Name":"JUTAI","Model Number":"LD-100","Certification":"CE","Place of Origin":"China"}}
{"title":"1ch Loop Detector With Pulse Presence Relay High Sensitivity For Container Truck","imgUrl":"https:\/\/img.chinax.com\/nimg\/51\/4c\/cb897c18d122881c0ed15c96f173-200x200-1\/1ch_loop_detector_with_pulse_presence_relay_high_sensitivity_for_container_truck.jpg","attrs":{"Brand Name":"JUTAI","Model Number":"LD-100","Certification":"CE","Place of Origin":"China"}}
{"title":"LD-100 Driveway Loop Detector Dual Relay Sensitivity 6 Way Selectable","imgUrl":"https:\/\/img.chinax.com\/nimg\/85\/ab\/723cf2d87697b28103b1a6a6ca15-200x200-1\/ld_100_driveway_loop_detector_dual_relay_sensitivity_6_way_selectable.jpg","attrs":{"Brand Name":"JUTAI","Model Number":"LD-100","Certification":"CE","Place of Origin":"China"}}
{"title":"110-240V Single Channel Delay Protection Function Induction Loop Detector Sensor","imgUrl":"https:\/\/img.chinax.com\/nimg\/eb\/4a\/ea5be4f3a784530619d2eb0bbced-200x200-1\/110_240v_single_channel_delay_protection_function_induction_loop_detector_sensor_2000uh.jpg","attrs":{"Brand Name":"JUTAI","Model Number":"LD-100","Certification":"CE","Place of Origin":"China"}}
The Parking Barrier Gate Loop Detector is a sensor designed specifically for parking barrier gates, capable of efficiently identifying and detecting all types of vehicles, including oversized vehicles, trucks, motorcycles, and more, ensuring automatic gate opening and closing.
Features:
Single Channel Vehicle detector.
Advantages:
Wide Sensing Range and High Sensitivity: with a sensing range from 15 to 2000μH and high sensitivity, it accurately detects various vehicles, ensuring reliable detection performance.
Automatic Reset Function: the sensor automatically resets in case of a malfunction, eliminating the need for manual intervention and enhancing system stability and reliability.
Multiple Detection Level Selection: featuring 16 selectable levels ranging from 0.008% DL/L to 2.50% DL/L, it can be adjusted according to specific requirements, suitable for different application scenarios.
40000V Lightning Protection: equipped with robust 40000V lightning protection, it effectively safeguards the sensor against damage from lightning strikes.
Wide Operating Environment Range: suitable for a wide range of operating environments, with a temperature range from -40°C to +70°C, ensuring stable operation even in harsh weather conditions.
Indicates and Switch:
Power Led: RED power LED indicates "Power ON".
Detecting Led:
Continuously On: Indicates vehicle detection.
Blinking slowly: Indicates loop is short circuit or the number of twists after the loop is not enough.
Blinking fast: Indicates loop is open circuit or too many twists after the loop.
Switch 1 (Trimpot), Sensitivity Selection:
Sensitivity of the loop can be adjusted by the trimpot labeled "Sensitivity". User can select 16 different settings by turning the trimpot with 0 being the least sensitive and "F" being the most sensitive.
Switch2 (Dipswitch Settings):
DIP1 & DIP2 Setting Special Functions:
DIP1 ON: Output has 2 seconds delay. (No relay output if the vehicle speed is over 8km/h).
DIP2 ON: Increase sensitivity to avoid unwilling relay off for leaving vehicle especially for trailer.
DIP3 & DIP 4 Setting Relay B Output:
DIP MODE
Relay B Output
Loop Coils Status_L
OFF OFF
When vehicle is moving out, output for relay B is 200m/s
Relay B Output Type_
ON OFF
When the vehicle has left, output for relay B is 600m/s
Relay B will be present output. No Relay B Output Type_
ON ON
Can be used to test the Loop. If the loop is faulty, Relay B will be on and it will switch off once the fault is fixed.
DIP 5 Setting Automatic Reset:
DIP MODE
Present Mode
ON
Vehicle can be permanently present (no auto - reset, unless vehicle has left or manual reset)
OFF
Normal mode (automatic reset after 30 minutes present of vehicle, used to solve the mistake operation. If it is recommended)
DIP6 & DIP7 & DIP 8 Setting Relay ADelay:
DIP MODE
Delay AOutput
OFF OFF OFF
0 sec Output
ON OFF OFF
2sec Output
OFF ON OFF
5sec Output
ON ON OFF
8 sec Output
OFF OFF ON
10 sec Output
ON OFF ON
15 sec Output
OFF ON ON
20sec Output
ON ON ON
30 sec Output
DIP9 & DIP 10 Setting Frequency (40 K to 100 KHz):
DIP MODE
Frequency
OFF OFF
High
ON OFF
Medium - High
OFF ON
Medium - Low
ON ON
Low
In the application, where two or more loop detectors and sensing loops have been installed, set one detector to high frequency and the other set to low frequency to minimize the effects of cross - talk between the two systems (The sensing loops and detectors should be positioned at least 2m apart).
Reset Button: Please note: The LD - 100 must be reset every time a setting change is made to the Dip switches.
Detector position and installation:
Install the detector in a weatherproof housing.
The detector should be as close to the sensing loop as possible.
The detector should always be installed away from strong magnetic fields.
Avoid running high voltage wires near the loop detectors.
Do not install the detector on vibrating objects.
When the control box is installed within 10 metres of the loop, normal wires can be used to connect the control box to the loop. More than 10 metres requires the use of a 2 core shielded cable. Do not exceed 30 metres distance between control box and loop.
Loop Installation:
The loops are sealed using a "quick - set" black epoxy compound or hot bitumen mastic to blend with the roadway surface.
Loop perimeter and Cylinder numbers:
Loop perimeter
Cylinder numbers
3 - 4M
6
4 - 6M
5
6 - 10M
4
10 - 20M
3
20M - UP
2
TroubleShooting:
If the detector is not working: Press reset.
If red led indicator is not fully lit: Check for power supply.
If green led indicator:
Blinks slowly: It maybe because the loop is short circuit or the no: of turns is not enough.
Blinks faster: It maybe because the loop is open or the no: of turns is too many.
If no: of turns is not enough: Lower the frequency (if the frequency is still to high, you must add more turns).
If no: of turns is too many: Higher the frequency (if the frequency is still to low, you must remove some turns).
Blinks slowly: may indicate a short circuit or insufficient number of turns <br> Blinks faster: may indicate an open loop or excessive number of turns
Response Times
Turn-on 10-90MS / Turn-off 10-90MS
Visual Indications
Power LED - Red <br> Channel LED - Green
Reset
Reset by push button on the front of the enclosure
Relay Output
Presence relay / Fault relay
Humidity
Up to 95% relative humidity without condensation
Switch 2 (Dipswitch Settings)
1.DIP 1 & DIP 2 Setting Special Functions
2.DIP 3 & DIP 4 Setting Relay B Output
3. DIP 5 Setting Automatic Reset
4. DIP 6 & DIP 7 & DIP 8 Setting Relay A Delay
5. DIP 9 & DIP 10 Setting Frequency (40 K to 100 KHz). Used to avoid the interference
Loop Installation:
Trouble Shooting:
Compared to other brands
Mass Production:
Our production line ensures efficient mass production, rigorous quality control, and thorough pre-shipment testing to deliver Loop detector products of the utmost perfection.
Certification:
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter
Year Established:
2012
Total Annual:
120000-150000
Employee Number:
50~70
Ecer Certification:
Verified Supplier
Shenzhen Jutai COMM Co., Ltd. is a high-tech privately-owned enterprise that integrates production, research and development, and sales. Our company is dedicated to the research and development as well as system integration of security products, achieving an intelligent one unified platform that int... Shenzhen Jutai COMM Co., Ltd. is a high-tech privately-owned enterprise that integrates production, research and development, and sales. Our company is dedicated to the research and development as well as system integration of security products, achieving an intelligent one unified platform that int...