China Zero Halogen Flame Retardant Cable 11KV Fire Resistant Low Smoke Cables
China Zero Halogen Flame Retardant Cable 11KV Fire Resistant Low Smoke Cables

  1. China Zero Halogen Flame Retardant Cable 11KV Fire Resistant Low Smoke Cables
  2. China Zero Halogen Flame Retardant Cable 11KV Fire Resistant Low Smoke Cables
  3. China Zero Halogen Flame Retardant Cable 11KV Fire Resistant Low Smoke Cables
  4. China Zero Halogen Flame Retardant Cable 11KV Fire Resistant Low Smoke Cables
  5. China Zero Halogen Flame Retardant Cable 11KV Fire Resistant Low Smoke Cables
  6. China Zero Halogen Flame Retardant Cable 11KV Fire Resistant Low Smoke Cables

Zero Halogen Flame Retardant Cable 11KV Fire Resistant Low Smoke Cables

  1. MOQ: 100m
  2. Price: 11.15-16.25USD
  3. Get Latest Price
Payment Terms T/T
Delivery Time 15-20days
Application Underground,Industrial,Construction,overhead,Power Station
Jacket PVC,Non,no jacket,PVC or XLPE,PVC/PE
Insulation material XLPE,PVC,Rubber,XLPE(XLPO),xlpe or pvc
Conductor material Copper,Aluminum,steel core aluminum strand,copper/aluminium,tin plated
Type Low Voltage,Medium Voltage,High Voltage,Insulated,Rigid/Flexible round
Standard IEC60502,IEC,BS,UL,JIS
Color Black,Red,blue,brown,Requirement
Product name Medium Voltage Power Cable,Fire Resistant 4core LV Armoured Electrical Cable XLPE Copper Cable,XLPE PVC insulated PVC sheathed 4 core copper power cable,steel tape armoured cable,Aerial Bundled Cable
Conductor Copper,Alulminum,Class 2 annealed copper strands,Cu / Al,strand
Insulation XLPE,XLPE PE PVC,PVC,PE,XLPE/PE/PVC
Rated voltage 0.6/1KV,3.6~35kv,8.7/10,3.6/6.6,6/10
Voltage 0.6/1KV,low voltage,medium voltage,300/500V,450/750V
Core 1 Core,5 core,duplex/triplex/quadruplex,3,Single
Sheath PVC,ZR-PVC,LSOH,Non-sheath,PE
Packing Wooden Drum,optional,Wooden-steel Drum
Conductor type Stranded,copper
Name 11KV SWA FIRE RETARDANT CABLE,welding cable,JKLGYJ 1KV overhead power cables
Armour Steel wire or Aluminum wire armor,Steel tape armour,STA/SWA/ATA/AWA,or unarmored
Item XLPE Copper Cable,Medium voltage XLPE cable
Brand Name JinHong
Model Number WDZN-YJY
Place of Origin Anhui China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Delivery Time 15-20days
Application Underground,Industrial,Construction,overhead,Power Station Jacket PVC,Non,no jacket,PVC or XLPE,PVC/PE
Insulation material XLPE,PVC,Rubber,XLPE(XLPO),xlpe or pvc Conductor material Copper,Aluminum,steel core aluminum strand,copper/aluminium,tin plated
Type Low Voltage,Medium Voltage,High Voltage,Insulated,Rigid/Flexible round Standard IEC60502,IEC,BS,UL,JIS
Color Black,Red,blue,brown,Requirement Product name Medium Voltage Power Cable,Fire Resistant 4core LV Armoured Electrical Cable XLPE Copper Cable,XLPE PVC insulated PVC sheathed 4 core copper power cable,steel tape armoured cable,Aerial Bundled Cable
Conductor Copper,Alulminum,Class 2 annealed copper strands,Cu / Al,strand Insulation XLPE,XLPE PE PVC,PVC,PE,XLPE/PE/PVC
Rated voltage 0.6/1KV,3.6~35kv,8.7/10,3.6/6.6,6/10 Voltage 0.6/1KV,low voltage,medium voltage,300/500V,450/750V
Core 1 Core,5 core,duplex/triplex/quadruplex,3,Single Sheath PVC,ZR-PVC,LSOH,Non-sheath,PE
Packing Wooden Drum,optional,Wooden-steel Drum Conductor type Stranded,copper
Name 11KV SWA FIRE RETARDANT CABLE,welding cable,JKLGYJ 1KV overhead power cables Armour Steel wire or Aluminum wire armor,Steel tape armour,STA/SWA/ATA/AWA,or unarmored
Item XLPE Copper Cable,Medium voltage XLPE cable Brand Name JinHong
Model Number WDZN-YJY Place of Origin Anhui China
High Light Zero Halogen Flame Retardant Cable11KV Fire Resistant Low Smoke CablesFlame Retardant Cable 11KV
WDZN-YJY LSZH Fire-Resistant Power Cable

Low Smoke Zero Halogen • Fire Resistant • XLPE Insulation • PE Sheath • Non-Armored

WDZN-YJY is a dual-protection safety cable built for projects where cables must not only stop burning, but also stay operational during fire conditions.

Flame retardant to limit spread • Fire resistant to maintain power • Eco-friendly & non-toxic • Lightweight & easy to install

Designed for non-direct-burial installations in ultra-high safety environments—such as high-rise towers, hospital operating areas, metro lines, airports, and emergency centers—this cable combines:

  • Low Smoke Zero Halogen (LSZH) flame-retardant technology
  • Certified fire resistance to maintain circuit integrity under flame
  • XLPE insulation & PE sheath for long-term stability
  • Non-armored, lightweight construction for easier installation

Engineered to meet stringent codes including GB/T 19666, GB 12666, GB/T 12666.6, it is tailored for projects facing the toughest fire safety acceptance checks.

 
Model Decoding - Double Safety in a Lightweight Design
What "WDZN-YJY" Means
Code Component Function & Safety Advantage
WDZ Low Smoke Zero Halogen Flame-Retardant System Halogen-free, low-smoke formulation. Under fire, smoke density stays low (≤50%) and no corrosive halogen acid gases are released. Helps prevent flame spread and limits damage to people and equipment.
N Fire-Resistant Function Indicates fire-resistance capability in line with GB/T 12666.6 Class N. Maintains circuit integrity for approximately 90 minutes at 750°C.
YJ Cross-Linked Polyethylene (XLPE) Insulation Supports continuous operation at 90°C with high insulation resistance (≥100 MΩ·km). Low dielectric loss improves transmission efficiency.
Y Polyethylene (PE) Sheath Environmentally friendly, non-toxic outer layer with strong resistance to UV, weathering, and low temperatures.
Compared to WDZ-YJY: WDZN-YJY adds fire-resistance capability to maintain power during fire events.
 
WDZN-YJY Fire-Resistant Cable product image showing construction and labeling
5 Key Advantages - Tailored for Critical Fire Safety Circuits
1. Flame-Retardant + Fire-Resistant - Two Layers of Protection

WDZN-YJY doesn't just slow fire; it's designed to keep critical systems energized:

  • Flame-retardant behavior: Limits flame propagation and avoids burning droplets
  • Fire-resistant core: Maintains circuit integrity for 90 minutes at 750°C
  • Emergency support: Ensures power for fire-fighting lifts, emergency lighting, sprinkler pumps, and evacuation signage
  • Low smoke, halogen-free: Minimal smoke and no toxic fumes for safer evacuation
 
2. Non-Armored & Lightweight - Made for Shafts, Trays & Conduits
  • Typically 25-30% lighter than comparable armored cables
  • Installation efficiency increases by approximately 30%
  • Minimum bending radius of only ≈15* cable diameter
  • Ideal for vertical shafts, cable trays, conduit wiring, and embedded runs
 
3. XLPE + PE Structure - Long Service Life & Stable Performance
  • XLPE insulation: Operating temperature up to 90°C, handles low temperatures around -40°C
  • PE sheath: Non-toxic, halogen-free with strong UV and weather resistance
  • High-purity copper conductor: Conductivity close to 99.97% IACS
  • Service life can exceed 25 years when installed correctly
 
4. High-Compliance Solution - Designed for Zero-Tolerance Fire Audits

Tailored for projects where fire inspections must be passed on the first attempt:

  • Supports dual requirements of "flame-retardant + fire-resistant" cables
  • Suitable for public infrastructure with strict acceptance rules
  • Meets both environmental expectations and emergency power continuity needs
 
5. Flexible Customization - Configuration Fits the Scenario
  • Flame-retardant grades: WDZ-A / WDZ-B / WDZ-C options
  • Fire-resistant categories: Class N / NH as needed
  • Core configurations: 1-5 cores, 1.5-400 mm² cross-sectional area
  • Voltage class: Upgradable designs up to approximately 10 kV
 
Technical Specifications - Typical WDZN-YJY Configurations
Cores * Section (mm²) Conductor Material XLPE Insulation (mm) PE Sheath (mm) Fire-Resistant Layer (mm) Approx. Outer Diameter (mm) Rated Voltage (kV) Approx. Weight (kg/km) DC Resistance at 20°C (Ω/km) Fire Resistance (GB/T 12666.6)
3 * 10 + 1 * 6 High-purity copper 1.0 1.8 0.5 25.8 0.6/1 420 ≤ 1.83 750°C * 90 min
3 * 16 + 1 * 10 High-purity copper 1.0 1.8 0.5 29.2 0.6/1 560 ≤ 1.15 750°C * 90 min
3 * 25 + 1 * 16 High-purity copper 1.2 2.0 0.6 33.8 0.6/1 780 ≤ 0.74 750°C * 90 min
3 * 50 + 1 * 25 High-purity copper 1.4 2.2 0.6 42.3 0.6/1 1320 ≤ 0.38 750°C * 90 min
4 * 120 High-purity copper 1.6 2.5 0.8 53.5 0.6/1 2450 ≤ 0.16 750°C * 90 min
5 * 240 High-purity copper 2.0 3.0 0.8 73.2 0.6/1 4800 ≤ 0.08 750°C * 90 min
Fire-resistant layer: Uses a ceramifiable silicone rubber formulation that turns into a rigid, ceramic-like shell in a fire, helping to shield the conductors from short circuits.
 
Typical Application Scenarios
High-Rise & Super High-Rise Buildings
Fire-resistant cabling for evacuation routes, emergency systems and main risers
Hospitals, Operating Theatres & Emergency Centers
Power supply to life-sustaining and emergency systems
Subways, Airports & Major Stations
Maintains power for evacuation signage and emergency lighting
Data Centers & Core Equipment Rooms
High-density zones needing halogen-free, low-smoke behavior
Schools, Kindergartens, Elderly Care Facilities
Buildings with vulnerable occupants requiring extra evacuation time
Large Shopping Malls & Commercial Complexes
High crowd density demanding dual-certified cables
 
WDZN-YJY cable installation in cable tray system Close-up view of WDZN-YJY cable construction and materials
Frequently Asked Questions
Q1: What is the main difference between WDZN-YJY and standard WDZ-YJY?
A: WDZ-YJY focuses on low smoke zero halogen flame-retardant performance. WDZN-YJY adds fire-resistance capability, meaning it can keep critical circuits energized during a fire.
Q2: When should I choose non-armored WDZN-YJY instead of an armored fire-resistant cable?
A: Choose non-armored WDZN-YJY when cables are routed through conduits, shafts, trays, ceilings or walls where they are not directly exposed to heavy mechanical loads.
Q3: How long can WDZN-YJY maintain power under fire conditions?
A: Under standard fire-resistance test conditions (750°C), WDZN-YJY maintains circuit integrity for approximately 90 minutes.
Q4: Does the LSZH formulation affect electrical performance?
A: No. The LSZH sheath and fire-resistant layer provide safety benefits while the XLPE insulation and copper conductor ensure solid electrical performance.
Q5: Can WDZN-YJY be used outdoors?
A: Yes, as long as it is not directly buried. The PE sheath offers strong UV and weather resistance.
Q6: Can you customize WDZN-YJY to match our local fire codes?
A: The cable can be configured with different flame-retardant and fire-resistance levels to align with local codes and project specifications.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2006

  • Total Annual:

    15000000000-20000000000

  • Employee Number:

    100~200

  • Ecer Certification:

    Verified Supplier

.gtr-container-mno456 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; max-width: 100%; overflow-x: hidden; } .gtr-container-mno456 .gtr-heading { font-size: 18px; font-... .gtr-container-mno456 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 15px; box-sizing: border-box; max-width: 100%; overflow-x: hidden; } .gtr-container-mno456 .gtr-heading { font-size: 18px; font-...

+ Read More

Get in touch with us

  • Reach Us
  • JinHong Wire And Cable Group
  • Factory :No. 9, Pengfeng Road, Tongyang Industrial Park, Chaohu City, Hefei City, Anhui Province.
  • https://www.cablejinhong.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement