China ABB IMASO11 Analog Output Module – INFI 90 OPEN
China ABB IMASO11 Analog Output Module – INFI 90 OPEN

  1. China ABB IMASO11 Analog Output Module – INFI 90 OPEN
  2. China ABB IMASO11 Analog Output Module – INFI 90 OPEN
  3. China ABB IMASO11 Analog Output Module – INFI 90 OPEN
  4. China ABB IMASO11 Analog Output Module – INFI 90 OPEN

ABB IMASO11 Analog Output Module – INFI 90 OPEN

  1. MOQ: 1
  2. Price: 66USD
  3. Get Latest Price
Packaging Original new packaging
Supply Ability in stock
Packaging Details Brand new and original
Payment Terms T/T
Delivery Time 2-3 work days
Place of shipment Xiamen,China
Quotation Time Quick Quote Within 24 Hours
Condition 100% Original
Model Number IMASO11
Brand Name ABB
Place of Origin SWEDEN

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Packaging Original new packaging Supply Ability in stock
Packaging Details Brand new and original Payment Terms T/T
Delivery Time 2-3 work days Place of shipment Xiamen,China
Quotation Time Quick Quote Within 24 Hours Condition 100% Original
Model Number IMASO11 Brand Name ABB
Place of Origin SWEDEN
High Light ABB Bailey IMASO11 1–5 VDC / 4–20 mAAnalog Output Module 10-Bit D/A ResolutionINFI 90 OPEN 14-Channel Analog Output
ABB IMASO11 Analog Output Module – INFI 90 OPEN
ABB Bailey IMASO11 Analog Output Module

ABB Bailey IMASO11 is an Analog Output (ASO) module for the INFI 90 OPEN Strategic Process Management System. It interfaces control modules with process field devices and is used by multifunction processor (MFP) or multifunction controller (MFC) modules to control process outputs. The module uses closed-loop output circuits with signal readback for output monitoring.

IMASO11 Technical Specifications
Technical Specifications
Product type Analog Output Module (ASO)
System INFI 90 OPEN
Analog outputs 14
Output signals 1-5 VDC or 4-20 mA
D/A resolution 10 bits
Output accuracy ≤0.15% in voltage mode; ≤0.25% in current mode
Output load 750 Ω maximum in current mode; 22 kΩ minimum in voltage mode
Current limiting / short-circuit protection 50 mA nominal output current limit
Output overvoltage category Category III
Power requirements +5 VDC ±5%, +15 VDC ±5%, −15 VDC ±5%, and +24 VDC ±10% from the termination unit/module
Typical current consumption 250 mA at +5 VDC; 100 mA at +15 VDC; 90 mA at −15 VDC; 310 mA at +24 VDC
Typical power dissipation 1.5 W at +5 VDC; 2 W at +15 VDC; 1.75 W at −15 VDC; 8 W at 24 VDC
Power overvoltage category Category I
Mounting One slot in a standard INFI 90 OPEN module mounting unit
Ambient temperature 0 to 70°C (32 to 158°F)
Relative humidity 0-95% up to 55°C, noncondensing; 0-45% at 70°C, noncondensing
Altitude Sea level to 3 km (1.86 miles)
Air quality Noncorrosive; pollution degree I
EMC EN50082-2, EN50081-2 and EN61010-1 when installed in an INFI 90 OPEN cabinet
Certification information CSA; FM listed as pending in the referenced instruction
Hazardous-location approval Nonincendive Class I Division 2, Groups A, B, C, D and Class II Division 2, Groups F, G
System Compatibility Information
System Compatibility

The module is designed for the INFI 90 OPEN architecture. It communicates with a multifunction processor or multifunction controller through the I/O expander bus. The module has a unique I/O address selected by its S1 address switch.

Historical Replacement: The manufacturer instruction explicitly states that IMASO11 can be used as a direct replacement for IMASO01.

Application and Maintenance
Application & Maintenance

IMASO11 is used in INFI 90 OPEN systems to send analog control signals from MFP/MFC modules to field devices.

Common Maintenance Scenarios
  • Incorrect or missing analog output
  • Module communication or enable faults
  • I/O expander bus errors
  • Incorrect module address or jumper settings
  • Termination or field wiring issues

These faults may affect process control and should be handled by qualified personnel following proper safety procedures.

Module Operation Details
Module Operation

Each output channel has a closed-loop current/voltage circuit. The module monitors the output feedback and uses the feedback signal for readback through an A/D converter and the I/O expander bus. This allows the MFP to read individual channel feedback values.

At startup, the outputs automatically go to 0 percent, corresponding to 1 VDC or 4 mA. On an error condition, the module uses a configured fixed/default output value.

Related Hardware Components
Related Hardware

Related hardware documented for IMASO11 includes:

  • IEMMU11/12/21/22 -- Module Mounting Units
  • IMMFC03/04/05 -- Multifunction Controllers
  • IMMFP01/02/03/03B -- Multifunction Processors
  • NTDI01 / NIDI01 -- Termination hardware
  • NKTU01/11, NKTU02/12, NKTM01 -- Termination cables
Amikon Support Services Amikon Customer Support
Support Services

Amikon supports industrial automation spare-part requirements with:

  • Pre-shipment testing
  • Protective packaging
  • DOA support
  • Return and replacement handling
  • Warranty support
  • After-sales assistance
Contact: Miya Zheng
WhatsApp: +86 180 2077 6792
Frequently Asked Questions
Frequently Asked Questions
Q1. What delivery, testing, packaging, DOA, return and warranty support is available for IMASO11?
A: Units are tested and securely packed before shipment. DOA, returns and warranty are handled according to the order terms.
Q2. What information is needed for an IMASO11 RFQ?
A: Please provide Part Number, Quantity, Destination, Required Date, and Machine/System Model.
Q3. What should be checked before installing IMASO11?
A: Check the MMU slot, I/O expander-bus connection, termination cable and module configuration. Disconnect power before working on backplane dipshunts.
Q4. How can IMASO11 status be checked?
A: Check the front-panel LEDs or review module status through the INFI 90 OPEN operator interface, EWS or CTT.
Q5. What maintenance is recommended for IMASO11?
A: Inspect the module, MMU, termination hardware and related connections periodically. Use ESD precautions and qualified personnel.
Q6. What information helps with IMASO11 troubleshooting?
A: Provide the fault description, LED status, system alarms and installation details. Module photos can also help confirm the unit.
Available Inventory Models
Available Inventory Models
AGDR-71C ACS550-01-06A9-4 CPM253-MR0005 A5E35341486 RS9000XL-40-01-00 TM0182-A50-B00-C00 ACS-AP-I IQ35F16B4 CC-PCNT02 51308386-176 51307715-176 TVF-M20GNPM CC-PDOB01 2SY5010-1LY05

These models are listed as available inventory only and are not official or compatible replacement models for IMASO11.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Trading Company

  • Year Established:

    2004

  • Total Annual:

    85682000-125000000

  • Employee Number:

    70~80

  • Ecer Certification:

    Verified Supplier

Company Profile Amikon Limited specializes in the global supply of industrial automation module spare parts.The company focuses on well-known international brands covering DCS systems, robot control systems, and large-scale servo control systems. Product scope includes: ➢Distributed Control Syste... Company Profile Amikon Limited specializes in the global supply of industrial automation module spare parts.The company focuses on well-known international brands covering DCS systems, robot control systems, and large-scale servo control systems. Product scope includes: ➢Distributed Control Syste...

+ Read More

Get in touch with us

  • Reach Us
  • AMIKON LIMITED
  • 32D units,GuoMao Building No 388 Hubin South Road Siming district Xiamen, Fujian China
  • https://www.dcscontroller.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement