Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"ABB 1MRK002133 ABR02 Analog Digital Module","imgUrl":"https:\/\/img.chinax.com\/nimg\/2b\/16\/a6f1c6168a7b4b59d0e5344f5eb8-200x200-1\/abb_1mrk002133_abr02_analog_digital_module.jpg","attrs":{"Model Number":"1MRK002133 ABR02","Payment Terms":"T\/T","Supply Ability":"in Stock","Brand Name":"ABB"}}
{"title":"ABB 07KP90 Communications Module with 24V DC Supply Voltage Compatible with","imgUrl":"https:\/\/img.chinax.com\/nimg\/fc\/08\/af7cd3a1b530131e8610142e529f-200x200-1\/abb_07kp90_communications_module_with_24v_dc_supply_voltage_compatible_with_advant_controller_31.jpg","attrs":{"Brand Name":"ABB","Model Number":"07KP90","Place of Origin":"SWEDEN","Minimum Order Quantity":"1"}}
{"title":"ABB Bailey IEPAS02 AC System Power Module","imgUrl":"https:\/\/img.chinax.com\/nimg\/12\/f9\/eff8bad8c11c1bcc8a72c366806c-200x200-1\/abb_bailey_iepas02_ac_system_power_module.jpg","attrs":{"Model Number":"IEPAS02","Brand Name":"ABB","Manufacturer":"ABB \/ Bailey"}}
An ABB analog–digital module used inside Relion 670-series protection and control IED hardware. It receives conditioned measuring quantities from the transformer input stage and converts them for the relay’s protection, measurement and supervision functions.
ADM MODULE ROLE
670 SERIES IED PLATFORM
ABR02 HARDWARE REVISION
INTERNAL PLUG-IN POSITION
01 · SIGNAL RELATIONSHIP
From Instrument Transformers to Protection Logic
∿
CT / VT circuits
Primary-system measuring quantities
▥
TRM stage
Configured current and voltage transformer inputs
◈
1MRK002133 ABR02
Analog-to-digital conversion
⌘
Protection IED
Measurement and protection algorithms
02 · TECHNICAL IDENTITY
Confirmed Hardware Attributes
Manufacturer
ABB
Order code
1MRK002133-ABR02
Hardware designation
ADM analog–digital module
System context
Relion 670-series protection and control IED
Observed host arrangement
ADM position used with a 6-current + 6-voltage TRM configuration
Replacement basis
Full IED order code, module revision, slot and transformer-input configuration
03 · DEPLOYMENT
Use, Installation and Commissioning
⌖ Use scope
High-voltage protection and control IEDs where the installed ABB 670 hardware build calls for this ADM revision.
⚙ Function
Digitizes conditioned measuring channels for relay measurement, protection, disturbance and supervision processing.
↧ Installation
Isolate the IED, observe electrostatic precautions, confirm slot and revision, seat connectors evenly and restore all internal links exactly.
✓ Commissioning
Run secondary injection across every configured current and voltage path and verify scaling, phase assignment and protection pickup.
04 · FAMILY COMPARISON
Revision Selection
EARLIER BUILD
ABR01
Same ADM family; use only when the host hardware definition permits it.
REQUESTED BUILD
ABR02
Exact revision for a like-for-like replacement of 1MRK002133 ABR02.
LATER BUILD
ABR03
Do not assume interchangeability without an ABB-approved hardware migration.
ACR FAMILY
ACR variants
Different revision family; host compatibility must be independently confirmed.
AMIKON · SINCE 2005
Industrial automation support built around uptime
PLC, HMI, DCS, industrial PC and drive spares for planned maintenance, difficult part-number matching and urgent recovery.
sales@amikon.cn
WhatsApp 86-18020776792
05 · BUYER FAQ
Compatibility Questions That Matter
❖ Q Can ABB 1MRK002133 ABR02 be replaced by ABR03?
◉ A Not automatically. The complete IED hardware definition, slot, connected TRM and approved revision compatibility must agree.
◆ Q Does ABB 1MRK002133 ABR02 connect directly to CT and VT secondary circuits?
◉ A The transformer input stage provides the conditioned measuring interface; the ADM performs conversion inside the IED.
◇ Q What test is essential after fitting ABB 1MRK002133 ABR02?
◉ A Secondary injection should verify every configured current and voltage channel, scaling, phase order and affected protection function.
✦ Q Is ABB 1MRK002133 ABR02 the complete protection relay?
◉ A No. It is an internal ADM component within a configured Relion 670-series IED.
❖ Q Why must the host order code be checked for ABB 1MRK002133 ABR02?
◉ A The host order code defines measuring inputs, supply, I/O population, communication hardware and internal module arrangement.
Company Profile
Amikon Limited specializes in the global supply of industrial automation module spare parts.The company focuses on well-known international brands covering DCS systems, robot control systems, and large-scale servo control systems.
Product scope includes:
➢Distributed Control Syste... Company Profile
Amikon Limited specializes in the global supply of industrial automation module spare parts.The company focuses on well-known international brands covering DCS systems, robot control systems, and large-scale servo control systems.
Product scope includes: