China factories

Chat Now Send Email
China factory - AMIKON LIMITED

AMIKON LIMITED

  • China,Xiamen ,Fujian
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China ABB CMA130 3DDE300410 SYNPOL D Display Front Panel
China ABB CMA130 3DDE300410 SYNPOL D Display Front Panel

  1. China ABB CMA130 3DDE300410 SYNPOL D Display Front Panel
  2. China ABB CMA130 3DDE300410 SYNPOL D Display Front Panel
  3. China ABB CMA130 3DDE300410 SYNPOL D Display Front Panel

ABB CMA130 3DDE300410 SYNPOL D Display Front Panel

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Delivery Time 2-3 work days
Payment Terms T/T
Place of Origin SWEDEN
Brand Name ABB

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Delivery Time 2-3 work days Payment Terms T/T
Place of Origin SWEDEN Brand Name ABB
High Light ABB CMA130 ,SYNPOL D Display Front Panel ,3DDE300410
AMIKON Industrial Automation Supply

ABB CMA130 3DDE300410

SYNPOL D Display Front Panel

Model: CMA130   |   Part No.: 3DDE300410
ManufacturerABB
Equipment PlatformSYNPOL D
Product CategoryOperator Display Panel

Product Overview

The ABB CMA130, part number 3DDE300410, is a display front panel for the SYNPOL D generator control and protection platform. SYNPOL D combines alternator protection, diesel-engine control and power management for generator installations, including marine power systems.

The operator panel provides local access to operating indications and system information. It is used alongside the SYNPOL D control hardware rather than as a standalone generator controller.

Replacement Identification Match the complete part number and existing equipment configuration before ordering. Confirm the intended application with the installed system documentation.

Technical Specifications

Manufacturer ABB
Model CMA130
Part Number 3DDE300410
Product Type Display front panel / local operator interface
System SYNPOL D
System Purpose Alternator protection, diesel control and power management
Operator Indications Generator voltage, current, power, frequency and power factor indications are described for the SYNPOL D control panel.
Display Arrangement SYNPOL D panel documentation describes green seven-segment LED indications, analog current and power light bands, and an LC display.
Display, operation and configuration notes

The SYNPOL D service documentation describes the LC display as an interface for device information, parameter viewing and programming. The alphanumeric keypad is used for entering values and navigating parameters.

Programming access uses a password, and parameter changes are confirmed through the panel's acknowledgement key. The manual warns that the PROG key should only be pressed when the engine is not running.

The SYNPOL D documentation also describes RS422/485 communication settings, including address, protocol selection and transmission speed. These are system-level settings; verify the installed configuration before changing any parameter.

Application & Failure Scenarios

SYNPOL D is designed for generator control, alternator protection and power management. The operator panel supports local observation of generator operating values and system information.

  • Missing or unreadable indications: Operators may lose local visibility of generator measurements, operating status or alarms, making diagnosis more difficult.
  • Panel keypad or display malfunction: Access to local parameter screens and operating information may be impaired, potentially delaying maintenance.
  • Generator protection or power-management issue: A system fault can require prompt inspection of alarms, control hardware and configuration. The display panel should not be assumed to be the cause without diagnosis.

Reduced visibility or delayed troubleshooting can extend downtime in generator installations. Check the complete SYNPOL D system before deciding whether the panel requires replacement.

Installation & Service Considerations

Use the applicable SYNPOL D service documentation and site procedures when inspecting or replacing the panel. Confirm the installed version and all associated connections before returning equipment to service.

SYNPOL D service instructions require damaged equipment or connecting cables to be checked by authorized service personnel before operation resumes. Do not change operating parameters or protection settings without the required authorization and system knowledge.

Delivery & Warranty

TestingInspection or functional testing can be discussed and confirmed before shipment. PackagingProtective packaging is arranged for dispatch according to the supplied item's handling needs.
WarrantyWarranty period and coverage are specified in the quotation or order confirmation. Returns & DOAReport damage or suspected defects promptly. Retain packaging and contact AMIKON for return authorization and assessment.

Request a Quote

Please provide the following information so the requested spare part and delivery requirements can be checked efficiently.

Part Number: 3DDE300410   |   Quantity: Required quantity   |   Destination: Country / City   |   Required Date: Target date   |   Machine/System Model: Installed SYNPOL D equipment
Industrial Spare Parts · Global Supply

AMIKON Industrial Supply

Supporting industrial maintenance teams with spare-part sourcing, order coordination and international delivery.

Miya Zheng
+86 180 2077 6792

Include the full part number and delivery destination in your enquiry.

AMIKON industrial spare parts sourcing and service

Frequently Asked Questions

1. Which SYNPOL D functions are accessible through the operator panel?

The SYNPOL D panel provides generator operating indications and an LC display for device information, parameter navigation and programming functions, subject to the installed system configuration.

2. Which generator values are shown on the SYNPOL D panel?

The system documentation describes indications for generator voltage, current, power, frequency and power factor. Current and power also have analog light-band indications.

3. Can the panel be replaced without checking the control system?

No. Confirm the complete part number, installed equipment configuration and applicable service instructions before replacing the panel.

4. Where can I obtain the CMA130 3DDE300410 pdf/manual/datasheet?

Consult the SYNPOL D service documentation and contact ABB support or the equipment supplier for model-specific documentation and confirmation of the replacement part.

5. What precautions apply when servicing SYNPOL D equipment?

Follow the applicable safety and isolation procedures. The service manual states that programming should only be entered when the engine is not running, and damaged equipment or connecting cables must be checked by authorized service personnel before operation resumes.

Related Models

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Trading Company

  • Year Established:

    2004

  • Total Annual:

    85682000-125000000

  • Employee Number:

    70~80

  • Ecer Certification:

    Verified Supplier

Company Profile Amikon Limited specializes in the global supply of industrial automation module spare parts.The company focuses on well-known international brands covering DCS systems, robot control systems, and large-scale servo control systems. Product scope includes: ➢Distributed Control Syste... Company Profile Amikon Limited specializes in the global supply of industrial automation module spare parts.The company focuses on well-known international brands covering DCS systems, robot control systems, and large-scale servo control systems. Product scope includes: ➢Distributed Control Syste...

+ Read More

Get in touch with us

  • Reach Us
  • AMIKON LIMITED
  • 32D units,GuoMao Building No 388 Hubin South Road Siming district Xiamen, Fujian China
  • https://www.dcscontroller.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement