Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Thyristors Motor Control 3 Phase Soft Starter 660V 7.5 Kw","imgUrl":"https:\/\/img.chinax.com\/nimg\/73\/6a\/c665b509c10438885340c97edf05-200x200-1\/thyristors_motor_control_3_phase_soft_starter_660v_7_5_kw.jpg","attrs":{"Brand Name":"ZFeng","Model Number":"ZF-R Series","Certification":"CE\u3001CB\u3001CCC\u3001ISO9001\u3001ISO14001\u3001ISO45001\u3001EN61439\u3001EN61000","Payment Terms":"L\/C,D\/A,D\/P,T\/T,Western Union,MoneyGram"}}
{"title":"High Medium Voltage Soft Starter Motor Controller 3 Phase SCRs Customized","imgUrl":"https:\/\/img.chinax.com\/nimg\/60\/ad\/dbf25f43b52ae3c15ceca16acfdd-200x200-1\/high_medium_voltage_soft_starter_motor_controller_3_phase_scrs_customized.jpg","attrs":{"Brand Name":"ZFeng","Model Number":"ZF-R Series","Certification":"CE\u3001CB\u3001CCC\u3001ISO9001\u3001ISO14001\u3001ISO45001\u3001EN61439\u3001EN61000","Payment Terms":"L\/C,D\/A,D\/P,T\/T,Western Union,MoneyGram"}}
{"title":"Three Phase Electric Motor Soft Starters 220v For Industrial Manufacturing","imgUrl":"https:\/\/img.chinax.com\/nimg\/35\/e6\/c51ed0bff0e1b8a4b52f613d6709-200x200-1\/three_phase_electric_motor_soft_starters_220v_for_industrial_manufacturing.jpg","attrs":{"Brand Name":"ZFeng","Model Number":"ZF-R Series","Certification":"CE\u3001CB\u3001CCC\u3001ISO9001\u3001ISO14001\u3001ISO45001\u3001EN61439\u3001EN61000","Payment Terms":"L\/C,D\/A,D\/P,T\/T,Western Union,MoneyGram"}}
{"title":"Heavy Duty Adjustable SCRs Motor Soft Starters VFD Control OEM","imgUrl":"https:\/\/img.chinax.com\/nimg\/5d\/1f\/531f9f7491ac4b7327ab2ccf149c-200x200-1\/heavy_duty_adjustable_scrs_motor_soft_starters_vfd_control_oem.jpg","attrs":{"Brand Name":"ZFeng","Model Number":"ZF-R Series","Certification":"CE\u3001CB\u3001CCC\u3001ISO9001\u3001ISO14001\u3001ISO45001\u3001EN61439\u3001EN61000","Payment Terms":"L\/C,D\/A,D\/P,T\/T,Western Union,MoneyGram"}}
{"title":"Bypass Soft Starter: Energy-Efficient Motor Control Solution With Built-in","imgUrl":"https:\/\/img.chinax.com\/nimg\/69\/c8\/82a95730af21349f188496942636-200x200-1\/bypass_soft_starter_3a_energy_efficient_motor_control_solution_with_built_in_contactor_for_smooth_start_2fstop.jpg","attrs":{"Brand Name":"ZFENG","Model Number":"ZF-R Series","Certification":"CE\u3001CB\u3001CCC\u3001ISO9001\u3001ISO14001\u3001ISO45001\u3001EN61439\u3001EN61000","Payment Terms":"L\/C,D\/A,D\/P,MoneyGram,Western Union,T\/T"}}
{"title":"Current Controlled 100 Hp Soft Starter Single Phase For Motor ODM","imgUrl":"https:\/\/img.chinax.com\/nimg\/96\/75\/f470df56593e82c3d25d9efdb07c-200x200-1\/current_controlled_100_hp_soft_starter_single_phase_for_motor_odm.jpg","attrs":{"Brand Name":"ZFeng","Model Number":"ZF-R Series","Certification":"CE\u3001CB\u3001CCC\u3001ISO9001\u3001ISO14001\u3001ISO45001\u3001EN61439\u3001EN61000","Payment Terms":"L\/C,D\/A,D\/P,T\/T,Western Union,MoneyGram"}}
A standard soft starter is a widely used device in the field of motor control. It achieves smooth starting of motors by controlling the starting voltage and current, reducing mechanical and electrical shocks during the starting process, thereby extending equipment lifespan and improving system reliability.
I. Working Principle of Standard Soft Starter
Standard soft starters typically use thyristors (SCRs) or solid-state relays (SSRs) as power devices. By adjusting the conduction angle of the thyristors, the output voltage is controlled, enabling the regulation of the motor starting process. The working process generally includes the following stages:
Voltage Ramp Start: At the beginning of startup, the soft starter gradually increases the output voltage at a preset ramp rate, allowing the motor speed to rise slowly and avoiding excessive starting current.
Current-Limited Start: During startup, the soft starter can limit the maximum starting current to prevent it from exceeding the capacity of the motor or the power grid.
Full-Voltage Operation: Once the motor reaches its rated speed, the soft starter switches the output voltage to full voltage, and the motor enters normal operation mode.
Soft Stop (Optional): During stopping, the soft starter can gradually reduce the output voltage, allowing the motor speed to decrease slowly and reducing mechanical shock.
II. Features of Standard Soft Starter
Smooth Start: By using voltage ramp or current-limited start, it avoids current surges during motor startup, reducing damage to the power grid and equipment.
Protection Functions: Built-in overload protection, short-circuit protection, under-voltage protection, over-voltage protection, etc., ensuring the safe operation of the motor and soft starter.
Adjustable Parameters: Users can adjust startup time, startup voltage, current limit value, and other parameters according to actual needs to optimize the startup process.
Easy Installation and Maintenance: Standard soft starters usually adopt a modular design, making installation convenient and maintenance simple.
Strong Compatibility: Suitable for various types of three-phase asynchronous motors, widely used in fans, pumps, compressors, conveyors, and other loads.
III. Application Scenarios of Standard Soft Starter
Fans and Pumps: During the startup of fans and pumps, soft starters can reduce water hammer effects and mechanical shocks, extending equipment lifespan.
Compressors: For heavy-duty equipment like compressors, soft starters can lower starting current, reducing the impact on the power grid.
Conveyors: During the startup of conveyors, soft starters can prevent material slippage or equipment damage.
Other Industrial Equipment: Such as crushers, mixers, grinders, etc., soft starters can improve the starting performance and reliability of the equipment.
IV. Selection Points for Standard Soft Starter
Motor Power: Choose a suitable soft starter model based on the motor's rated power, ensuring that the soft starter's rated current is greater than the motor's rated current.
Load Type: Select the appropriate starting method (such as voltage ramp start, current-limited start) based on the load type (e.g., fan, pump, compressor).
Grid Conditions: Consider the grid's voltage, frequency, and capacity, and choose a suitable soft starter to avoid excessive impact on the grid.
Environmental Conditions: Choose a soft starter with the appropriate protection level according to the installation environment (such as temperature, humidity, altitude).
Functional Requirements: Select a soft starter with the necessary functions based on actual needs, such as whether soft stopping, communication functions, or display functions are required.
V. Installation and Commissioning of Standard Soft Starter
Installation:
Ensure that the soft starter is installed in a well-ventilated location, avoiding direct sunlight and humid environments.
Connect the power lines, motor lines, and control lines correctly according to the instructions.
Ensure proper grounding to prevent electric shock accidents.
Commissioning:
Check all wiring for correctness before startup to ensure there are no short circuits or open circuits.
Set the startup time, startup voltage, current limit value, and other parameters according to actual needs.
Perform a no-load test run to check the soft starter's operating status and the motor's startup condition.
Perform a load test run to observe the motor's operating performance and the soft starter's protection functions.
VI. Maintenance and Care of Standard Soft Starter
Regular Inspection: Regularly check the soft starter's appearance, wiring, and cooling condition to ensure normal operation.
Cleaning and Maintenance: Regularly clean the soft starter's cooling fins and fans to prevent dust buildup from affecting cooling performance.
Parameter Calibration: Regularly calibrate the soft starter's parameters to ensure normal startup performance and protection functions.
Fault Handling: If a soft starter fault is detected, immediately cut off the power supply and contact a professional for repair.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2004
Total Annual:
10000000-15000000
Employee Number:
60~100
Ecer Certification:
Verified Supplier
GuangDong Zhufeng Electric Co.,LTD established in 2004, is a national high-tech and energy save enterprise with approval by National Development and Reform Commission. Focusing on the development and production and sale of products of “energy saving and control speed and variable speed” ... GuangDong Zhufeng Electric Co.,LTD established in 2004, is a national high-tech and energy save enterprise with approval by National Development and Reform Commission. Focusing on the development and production and sale of products of “energy saving and control speed and variable speed” ...