Payment Terms | Online order,T/T |
Supply Ability | 100 Unit/Week |
Delivery Time | 5-8 working days |
Packaging Details | Neutral carton |
Product name | Air Quality Online Monitoring System |
Particulate Matter (PM) | PM₂.₅, PM₁₀, PM₁₀₀, TSP |
Inorganic Gases | SO₂, NO₂, CO, O₃, TVOC |
Meteorological Parameters | Temperature, Humidity, Wind Speed, Wind Direction, Atmospheric Pressure |
Data Transmission | 4G transmission; Capable of uploading to data platforms; |
Ingress Protection (IP) | IP53 |
Power Supply | AC 220V |
Installation Method | Pole-mounted/Bracket-mounted |
Brand Name | JUGE |
Model Number | AG-600-A8 |
Certification | IOS9001, CE |
Place of Origin | Nanjing, China |
View Detail Information
Explore similar products
NMHC THC CH4 Online Gas Analyzer For Vocs Waste Gas Non-Methane Total Hydrocarbo
PM1.0 PM2.5 PM10 PM100 TSP Dust And Noise Online Monitoring System
SO2 NO NO2 Online Continuous Emission Monitoring System CEMS Online Gas Analyzer
Online Continuous Emission Monitoring System For Vocs Gas Chromatography Fid Non
Product Specification
Payment Terms | Online order,T/T | Supply Ability | 100 Unit/Week |
Delivery Time | 5-8 working days | Packaging Details | Neutral carton |
Product name | Air Quality Online Monitoring System | Particulate Matter (PM) | PM₂.₅, PM₁₀, PM₁₀₀, TSP |
Inorganic Gases | SO₂, NO₂, CO, O₃, TVOC | Meteorological Parameters | Temperature, Humidity, Wind Speed, Wind Direction, Atmospheric Pressure |
Data Transmission | 4G transmission; Capable of uploading to data platforms; | Ingress Protection (IP) | IP53 |
Power Supply | AC 220V | Installation Method | Pole-mounted/Bracket-mounted |
Brand Name | JUGE | Model Number | AG-600-A8 |
Certification | IOS9001, CE | Place of Origin | Nanjing, China |
High Light | O3 Online Gas Monitoring System ,Online Gas Monitoring Micro Station ,NO2 Online Gas Monitoring System |
Grid-based Air Quality Monitoring Micro Station PM2.5 SO2 CO NO2 O3 TVOC Online Gas Monitoring System
>>Overview
High Integration: Can simultaneously integrate sensors for particulate matter, SO₂, CO, NO₂, O₃, TVOC, and meteorological five-parameter sensors.
Optical Sizing: Utilizes optical particle sizing technology for simultaneous monitoring of PM₁.₀, PM₂.₅, PM₁₀, and TSP.
Constant Flow Control: Incorporates flow feedback for constant flow control, ensuring sampling volume stability and enhancing accuracy.
Built-in Protection: Features sheath gas protection and gas path protection functions.
Professional Design: Structural design by professional design institutes for easy installation.
Tiered Air Paths: Features dual-pump air paths with main channel for particulates and auxiliary channel for gas modules.
Data Stability: Equipped with temperature and humidity sensing, gas cross-interference algorithms, zero drift compensation, and calibration across measurement ranges.
Dynamic Dehumidification: Can be equipped with a dynamic heating dehumidification sampling system to avoid data distortion in humid environments.
Data Transmission: 4G, RS232/RS485.
Data Export: Features USB port and/or SD card slot, supporting local data export (includes local storage with capacity >530,000 records).
Weather Resistance: Protection against rain, snow, and lightning.
Traceability: Traceable to NIST (National Institute of Standards and Technology).
Resume Transmission: Features power failure protection and data resume/re-transmission upon network restoration.
Information & QC: Includes device information management, data management, and data quality control functions.
Local Display: Equipped with LCD display and local debugging functions.
Multi-stage Filtration: Incorporates a two-stage or higher filtration system to prevent foreign matter from affecting sensor accuracy and precision.
Service Life: Main unit >10 years; Particulate Matter Sensor >5 years; Gas Sensors >2 years.
Calibration/Zeroing: Supports automatic/manual zero calibration and calibration functions.
Particulate Matter (PM) | |
Measurement Method | Laser Scattering |
Measured Parameters | PM₂.₅, PM₁₀, PM₁₀₀, TSP |
Concentration Range | 0 - 30 mg/m³ |
Concentration Precision | 0.1 µg/m³ |
Concentration Accuracy | ±10% |
Inorganic Gases | |
Measurement Method | Electrochemical Method |
Measured Parameters | SO₂, NO₂, CO, O₃, TVOC |
Concentration Range | SO₂: 0-1 ppm NO₂: 0-1 ppm CO: 0-200 ppm O₃: 0-5 ppm TVOC: 0-20 ppm |
Concentration Precision | SO₂: 0.001 ppm NO₂: 0.001 ppm CO: 0.01 ppm O₃: 0.001 ppm TVOC: 0.001 ppm |
Concentration Accuracy | SO₂: ±5% NO₂: ±5% CO: ±5% O₃: ±5% TVOC: ±5% |
Meteorological Parameters | |
Temperature | Range: -50 ~ 100°C; Accuracy: ±0.3°C |
Humidity | Range: 0 ~ 100% RH; Accuracy: ±3% RH |
Wind Speed | Range: 0~30 m/s; Accuracy: ±1 m/s (≤10 m/s), ±10% (>10 m/s) |
Wind Direction | Range: 0~360°; Accuracy: ±3° |
Atmospheric Pressure | Range: 1~120 kPa; Accuracy: ±0.15 kPa |
Data Transmission | 4G transmission; Capable of uploading to data platforms; Compliant with China's standard HJ212-2017 communication protocol. |
Ingress Protection (IP) | IP53 |
Power Supply | AC 220V |
Output Interfaces | RS232, RS485, etc. |
Installation Method | Pole-mounted/Bracket-mounted |
Company Details
Business Type:
Manufacturer
Year Established:
2015
Employee Number:
50~100
Ecer Certification:
Verified Supplier
JUGE was established in 2015, specializing in the field of environmental online monitoring. With environmental online monitoring systems at its core, JUGE integrates R&D, production, sales, and after-sales services. It is recognized as both a National High-Tech Enterprise and a "Specialized, Ref... JUGE was established in 2015, specializing in the field of environmental online monitoring. With environmental online monitoring systems at its core, JUGE integrates R&D, production, sales, and after-sales services. It is recognized as both a National High-Tech Enterprise and a "Specialized, Ref...
Get in touch with us
Leave a Message, we will call you back quickly!