Payment Terms | Online order,T/T |
Supply Ability | 100 Unit/Week |
Delivery Time | 5-8 working days |
Packaging Details | Neutral carton |
Product name | Dust and Noise Online Monitoring System |
Particulate Matter (PM) | PM₂.₅, PM₁₀, PM₁₀₀, TSP |
Noise Monitoring | 30–130 dB(A) |
Environmental Parameters | Temperature, Humidity, Wind Speed, Wind Direction, Atmospheric Pressure |
Local Display | 4-line display |
Data Transmission | 4G/5G/RS232/RS485 |
Power Supply | AC 220V 50Hz; 150W; Protections: leakage/overload/surge |
Brand Name | JUGE |
Model Number | AG-600-A8 |
Certification | IOS9001, CE |
Place of Origin | Nanjing, China |
View Detail Information
Explore similar products
NMHC THC CH4 Online Gas Analyzer For Vocs Waste Gas Non-Methane Total Hydrocarbo
Grid-based Air Quality Monitoring Micro Station PM2.5 SO2 CO NO2 O3 TVOC
SO2 NO NO2 Online Continuous Emission Monitoring System CEMS Online Gas Analyzer
Online Continuous Emission Monitoring System For Vocs Gas Chromatography Fid Non
Product Specification
Payment Terms | Online order,T/T | Supply Ability | 100 Unit/Week |
Delivery Time | 5-8 working days | Packaging Details | Neutral carton |
Product name | Dust and Noise Online Monitoring System | Particulate Matter (PM) | PM₂.₅, PM₁₀, PM₁₀₀, TSP |
Noise Monitoring | 30–130 dB(A) | Environmental Parameters | Temperature, Humidity, Wind Speed, Wind Direction, Atmospheric Pressure |
Local Display | 4-line display | Data Transmission | 4G/5G/RS232/RS485 |
Power Supply | AC 220V 50Hz; 150W; Protections: leakage/overload/surge | Brand Name | JUGE |
Model Number | AG-600-A8 | Certification | IOS9001, CE |
Place of Origin | Nanjing, China | ||
High Light | Dust Online Monitoring System ,TSP Online Monitoring System ,Noise Online Monitoring System |
PM1.0 PM2.5 PM10 PM100 TSP Dust and Noise Online Monitoring System
>>Overview
Modular Design: Configurable with flexible combinations to customize monitoring factors as needed, suitable for large-scale grid deployment.
Self-Calibration: Features optically stable self-calibration and online zero-correction systems to eliminate long-term operational drift. Traceable to national standard stations.
Multi-Size Particle Monitoring: Measures PM₁.₀, PM₂.₅, PM₁₀, PM₁₀₀, and TSP simultaneously via metallic cutters without replacing sampling components.
Dynamic Humidity Control: Utilizes dynamic heating dehumidification with continuous humidity compensation to minimize environmental interference.
Robust Sampling System: Long-life, low-noise, anti-interference pump with adjustable sampling cycles.
Flexible Data Transmission: Integrated 4G/5G, RS485, and wireless units support data transfer via GPRS/CDMA, 3G/4G/5G networks, or dedicated lines. Enables 24/7/365 operation, remote parameter adjustment, and fault diagnosis.
Expandable Sensors: Optional modules for meteorological parameters (negative oxygen ions, rainfall, radiation, UV, etc.).
Intelligent Imaging: Configurable cameras with night vision and long-range capture capabilities; supports auto-snapshot, video overlay, and real-time viewing.
Particulate Matter (PM) | |
Measurement Method | Laser Scattering |
Measured Parameters | PM₂.₅, PM₁₀, PM₁₀₀, TSP |
Concentration Range | PM₂.₅: 0-1000 μg/m³; PM₁₀: 0-2000 μg/m³; TSP: 0-30 mg/m³ (customizable) |
Concentration Precision | 0.1 µg/m³ |
Concentration Accuracy | ±2.5% or ±10 μg/m³ (whichever is greater) |
Pump Flow Rate | 2.83 L/min; PID-controlled ±2.5%; Accuracy: ±2.5% F.S. |
Dehumidification | DHS (Dynamic Heating System) with dynamic humidity control |
Particle Size Range | 0.3–100 μm |
Gas Path Protection | Standard |
Temperature Control | Adjustable (10–60°C ±1°C) |
Noise Monitoring | |
Measurement Range | 30–130 dB(A) |
Response Time | 200 ms |
Resolution | 0.1 dB |
Accuracy | ±0.5% F.S. |
Environmental Parameters | |
Temperature | Range: -40°C to +70°C; Resolution: 0.1°C; Accuracy: ±0.2°C |
Humidity | Range: 0–100% RH; Resolution: 0.1% RH; Accuracy: ±3% RH |
Wind Speed | Range: 0–60 m/s; Resolution: 0.1 m/s; Accuracy: ±(0.3 + 0.03V) m/s |
Wind Direction | Range: 0–360°; Resolution: 1°; Accuracy: ±3° |
Atmospheric Pressure | Range: 45–120 kPa; Resolution: 0.01 kPa; Accuracy: ±0.05 kPa (25°C @ 103.5 kPa) |
Local Display | 4-line display; Switch power supply; RS485 interface; Dimensions: 1020×540×120 mm |
Mounting Setup | 3m national-standard pole (or bracket); Lightning rod (Ø89 mm, 2 mm thickness, two 1.5m threaded rods). Wall-mount optional. |
Data Transmission | 4G/5G/RS232/RS485; Compliant with Chinese national standard HJ 212-2017 |
Power Supply | AC 220V 50Hz; 150W; Protections: leakage/overload/surge |
Operating Environment | Temperature: -40°C to +70°C; Humidity: 0–95% RH (non-condensing); IP53 rating |
Host Functions | |
Data Capture Rate | ≥90% for particulate data |
Local Storage | ≥24 months of historical data |
Data Recovery | Auto-recovery and retransmission upon network restoration |
Linkage System | Supports mist cannon and spray linkage |
Remote Management | Remote firmware updates, parameter configuration, linkage control, and diagnostics |
Company Details
Business Type:
Manufacturer
Year Established:
2015
Employee Number:
50~100
Ecer Certification:
Verified Supplier
JUGE was established in 2015, specializing in the field of environmental online monitoring. With environmental online monitoring systems at its core, JUGE integrates R&D, production, sales, and after-sales services. It is recognized as both a National High-Tech Enterprise and a "Specialized, Ref... JUGE was established in 2015, specializing in the field of environmental online monitoring. With environmental online monitoring systems at its core, JUGE integrates R&D, production, sales, and after-sales services. It is recognized as both a National High-Tech Enterprise and a "Specialized, Ref...
Get in touch with us
Leave a Message, we will call you back quickly!