Payment Terms | L/C, T/T, D/A, D/P |
Supply Ability | 12000PCS/YEAR |
Delivery Time | 30 work days |
Packaging Details | Export wooden packing |
Installation method | 9±1mm |
Average opening speed | 1.2±0.2 |
Average closing speed | 0.8±0.2 |
Bounce time of contact closing | ≤2 |
Center distance between phases | 340±2、280±2 |
Weight | ≈70kg |
Brand Name | HERONG ELECTRIC |
Certification | ISO9001 |
Place of Origin | XI'AN CHINA |
View Detail Information
Explore similar products
252kV SF6 HV AC Circuit Breaker 60000 Times Mechanical Life For Outdoor
Solid Insulation 12KV High Voltage Vacuum Circuit Breaker Modular Operating
Three Phase SF6 Circuit Breaker Pole Mounted Vacuum Circuit Breaker
EVSP3 Solid Sealed SF6 Circuit Breaker High Voltage Vacuum Circuit Breaker
Product Specification
Payment Terms | L/C, T/T, D/A, D/P | Supply Ability | 12000PCS/YEAR |
Delivery Time | 30 work days | Packaging Details | Export wooden packing |
Installation method | 9±1mm | Average opening speed | 1.2±0.2 |
Average closing speed | 0.8±0.2 | Bounce time of contact closing | ≤2 |
Center distance between phases | 340±2、280±2 | Weight | ≈70kg |
Brand Name | HERONG ELECTRIC | Certification | ISO9001 |
Place of Origin | XI'AN CHINA | ||
High Light | 10KV SF6 Circuit Breaker ,Hv SF6 Circuit Breaker ,SF6 Hv Vacuum Circuit Breaker |
When a fault occurs in the user's T-connection of the 10kV overhead distribution line, such as the fault is in its incoming line, or although the fault occurs inside the user's incoming switch but its protection action time limit is not matched with the substation outgoing switch protection, it will cause the substation to go out. The switch protection has tripped. If the nature of the fault is permanent and the substation recloses unsuccessfully, an accident in the medium-voltage user sector will cause the entire distribution line to be out of power. This common spreading accident in the distribution network will have a bad impact on the society.
The ZW32-10KVoutdoor high-voltage AC boundary vacuum circuit breaker is an ideal device to solve the above-mentioned accidents. A zero-sequence current transformer is built in the outlet side of the device, which is used in conjunction with the boundary controller. Installed at the T-connection or user end of 10kV overhead distribution lines, it can automatically remove single-phase ground faults and automatically isolate phase-to-phase short-circuit faults. Ensure the safety of electricity for non-faulty users. It is suitable for use in substations, industrial and mining enterprises, and rural power distribution systems for protection and control and frequent operations.
Company Details
Business Type:
Manufacturer,Trading Company
Year Established:
2004
Total Annual:
150000000-200000000
Employee Number:
900~1000
Ecer Certification:
Active Member
Shaanxi Herong Electric Group Co., Ltd., established in March 2004, located in National Economic and Technological Development Zone Xi'an, China, which is a hightech enterprises as well as a collection of scientific research and development, domestic and foreign trade, domestic and inte... Shaanxi Herong Electric Group Co., Ltd., established in March 2004, located in National Economic and Technological Development Zone Xi'an, China, which is a hightech enterprises as well as a collection of scientific research and development, domestic and foreign trade, domestic and inte...
Get in touch with us
Leave a Message, we will call you back quickly!