| Delivery Time | 1 week |
| Packaging Details | carton |
| Protection Class | IP55 |
| Ambient Humidity | 0~100% RH |
| Voltage | 220V Electrical Equipment, 110 V |
| Detecting Gas | Hydrogen Sulfide |
| Model | MY P520 |
| Dew Point Accuracy | ±1℃(-60℃~+20℃) |
| Payment Terms | L/C,D/A,D/P,T/T,Western Union |
| Warranty | 2 YEARS |
| Accuracy | other |
| Type | Testing Machine |
| Ambient Temperature | -40℃~+60℃ |
| Supply Ability | 1000pcs/month |
| Place of origin | Hebei, China |
| Power | electric |
| Brand Name | MINGYANG |
| Model Number | MY-VT |
| Place of Origin | China Mainland |
View Detail Information
Explore similar products
Portable Fast Response Dew Point Analyzer With Humidification Generator For
Portable SF6 Gas Analyzer With 0.01 High Accuracy Digital LCD Screen
P860 Oxygen Nitrogen Analyzer For Industry High Precision On Line Nitrogen
Intelligent High-Precision Automatic SF6 Density Relay Calibrator | Portable
Product Specification
| Delivery Time | 1 week | Packaging Details | carton |
| Protection Class | IP55 | Ambient Humidity | 0~100% RH |
| Voltage | 220V Electrical Equipment, 110 V | Detecting Gas | Hydrogen Sulfide |
| Model | MY P520 | Dew Point Accuracy | ±1℃(-60℃~+20℃) |
| Payment Terms | L/C,D/A,D/P,T/T,Western Union | Warranty | 2 YEARS |
| Accuracy | other | Type | Testing Machine |
| Ambient Temperature | -40℃~+60℃ | Supply Ability | 1000pcs/month |
| Place of origin | Hebei, China | Power | electric |
| Brand Name | MINGYANG | Model Number | MY-VT |
| Place of Origin | China Mainland | ||
| High Light | Gas Recovery sf6 analyzer ,IP55 sf6 analyzer ,electric sf6 analyser | ||
Mobile Hand-pushed SF6 Gas Vacuumizing Filling Inflator | SF6 Gas Evacuation Charging Testing Equipment
Product Description
This hand-pushed SF₆ gas evacuation and filling device is a professional on-site maintenance solution purpose-built for high-voltage power systems. It combines vacuum pumping, precision gas charging, and pressure testing capabilities into a single mobile trolley unit, engineered to support the installation, commissioning, and routine maintenance of SF₆-insulated electrical equipment across substations, power plants, and field engineering projects. Constructed with a heavy-duty carbon steel frame and full stainless steel gas circuits, the unit maintains stable and reliable operation even in harsh outdoor working conditions. It effectively streamlines on-site maintenance workflows, reduces equipment downtime, and safeguards the insulation and arc-extinguishing performance of high-voltage apparatus including GIS, circuit breakers, and instrument transformers.
Product Alias
Features
Equipped with high-precision pressure gauges, adjustable regulating valves and a digital display module for accurate SF₆ gas filling and vacuum evacuation, with real-time pressure and status monitoring to strictly comply with high-voltage equipment process requirements
Integrated hand-push frame with wear-resistant rubber wheels and stable support feet, enabling flexible movement across substation sites and secure positioning during operation to adapt to scattered field maintenance tasks
Full stainless steel gas pipelines and pressure-bearing components with high-standard sealing performance, effectively preventing SF₆ gas leakage and corrosion while meeting industrial safety specifications for long-term reliable operation
All-in-one design completes vacuum pumping, gas charging, and on-site tightness testing in a single unit, eliminating the need for multiple sets of tools and lowering overall maintenance costs
Compact trolley structure with ergonomic handles, suitable for on-site servicing of GIS, SF₆ circuit breakers, high-voltage switchgears and other SF₆-insulated electrical equipment
Product Parameters
| Parameter | Specification |
|---|---|
| Type | Testing Machine |
| Brand Name | MingYang |
| Place of Origin | Wuhan, China |
| Rated Voltage | 110 V / 220 V |
| Power Type | Electric |
| Power Configuration | AC 220V with built-in rechargeable battery |
| Battery Performance | 10 hours of continuous operation after 20 hours full charge |
| Protection Class | IP55 |
| Detecting Gas | Hydrogen Sulfide |
| Dew Point Range | -60 ℃ ~ +20 ℃ |
| Dew Point Accuracy | ±1℃ (within -60℃ ~ +20℃) |
| Accuracy Grade | Other |
| Ambient Temperature | -40℃ ~ +60℃ |
| Operating Temperature | -40℃ ~ +80℃ |
| Ambient Humidity | 0 ~ 100% RH |
| Warranty | 1 Year |
| Customized Support | OEM |
Application Scenarios
![]()
(Scenarios covered in the images:Widely used in substations, GIS switchgear rooms, high-voltage circuit breaker maintenance sites and on-site power equipment commissioning.)
Frequently Asked Questions from Customers
Question 1: Vacuum degree fails to reach the limit value
Customer: We are carrying out vacuum pumping for SF6 GIS equipment on site. After the equipment runs continuously for a long time, the vacuum gauge reading remains stagnant and cannot drop to the required ultimate vacuum. What are the possible causes?
Manufacturer: This issue is usually caused by circuit leakage or degraded vacuum pump performance. We recommend troubleshooting in sequence: first, inspect all quick connectors, flange interfaces and valve seals of the entire gas circuit, and use soapy water to check for leakage points, especially the connection part between the device and the tested equipment. Second, confirm that all valves on the gas path are fully opened, and check whether the pipeline filter element is blocked by impurities. Third, check whether the vacuum pump oil is insufficient or deteriorated; insufficient or emulsified pump oil will directly reduce the pumping capacity and ultimate vacuum. If all the above checks are normal, isolate the tested equipment and perform a separate vacuum test on the device itself to determine whether the leakage comes from the tested object. Please contact us if the problem persists, and do not disassemble the vacuum pump assembly without permission.
Question 2: Slow gas filling and failure to reach the set pressure
Customer: The vacuum pumping function works normally, but during SF6 gas filling, the pressure rises extremely slowly, and it cannot reach the preset filling pressure even after prolonged operation. How to fix this issue?
Manufacturer: This problem is generally caused by insufficient gas source pressure, blocked gas circuit or improper parameter setting. The following measures can be taken: First, check the remaining pressure of the SF6 gas cylinder. When the gas source pressure is close to or lower than the target filling pressure, continuous boosting cannot be achieved; replace a fully pressurized gas cylinder if necessary. Second, check whether the air inlet filter element and the internal pipeline of the device are blocked, and clean or replace the filter element regularly. Third, properly adjust the output pressure of the pressure reducing valve to avoid excessively low setting of the outlet pressure. In addition, low ambient temperature will cause SF6 gas liquefaction and slow down the filling speed; it is recommended to warm the gas cylinder properly or perform the operation at suitable temperature. If the tested equipment itself has obvious leakage, it will also show as unable to maintain pressure; it is recommended to conduct a tightness test after filling.
Question 3: Pressure drop during gas holding test
Customer: After completing SF6 gas filling and starting the holding test, the pressure drops obviously in a short time. We suspect there is a gas leakage. How should we locate the leakage point?
Manufacturer: It is recommended to carry out step-by-step investigation from external circuit to the device itself. First, check all quick connectors, hose interfaces and valve connections between the device and the tested equipment, and apply soapy water or SF6 leak detector to key sealing positions for leak detection, and retighten or replace the sealing ring if leakage is found. Second, isolate the tested equipment and conduct an independent pressure holding test on the device itself to determine whether the leakage comes from the tested object or the internal gas circuit of the device. Third, check whether all valves are fully closed after the test; incomplete closing of the valve will also cause slow pressure drop. If internal leakage of the device is confirmed, please contact our after-sales personnel for maintenance, and do not disassemble the sealing components without permission.
Question 4: Device fails to power on / no display on control panel
Customer: The control panel has no response after connecting to the on-site power supply, and the built-in battery cannot start the device either. What may cause this problem?
Manufacturer: Please troubleshoot according to the following steps: First, confirm that the input power supply voltage matches the device rating (110V/220V), and check whether the power socket and power cord are in normal conduction with a multimeter. Second, check whether the equipment power fuse is blown; if it is blown, replace it with a fuse of the same specification. Third, if using the built-in battery, confirm that the battery main switch is turned on, and judge whether the battery is in over-discharge protection state; if the device has not been charged for a long time, please connect it to AC power for more than 2 hours before trying to start it. If the fault still exists after the above inspection, it may be a failure of the control module; please contact us for technical support and do not open the electric control box privately.
Question 5: Slow SF6 gas recovery / incomplete recovery
Customer: When recovering SF6 gas from the tested equipment, the recovery speed is very slow, and there is always residual gas that cannot be pumped out completely. How to solve this problem?
Manufacturer: This situation is mostly related to pipeline configuration, gas source state or parameter setting. You can optimize it through the following measures: First, shorten the length of the recovery connecting pipeline as much as possible and reduce intermediate joints; excessively long pipelines will increase flow resistance and reduce recovery efficiency. Second, when the pressure of the tested equipment drops to a low level, start the vacuum pumping function for auxiliary recovery, which can greatly reduce the residual gas. Third, check whether the internal filter element of the recovery system is blocked; long-term use without replacement will reduce the gas flow rate. In addition, too low ambient temperature will cause SF6 gas liquefaction and slow down the recovery speed; it is recommended to carry out recovery operation when the ambient temperature is above 0℃.
Shipping scenario
![]()
Attachment Directory
| Item | Specification | Quantity |
|---|---|---|
| SF6 high-pressure gas hose | 3m & 5m, with self-sealing quick couplings | 2 pcs |
| Power supply cable | Matches 110V/220V input | 1 pc |
| Equipment adapter connector set | Compatible with GIS and SF6 circuit breaker ports | 1 set |
| Operation & maintenance manual | English version | 1 pc |
| Factory inspection certificate & test report | Calibration documentation | 1 set |
| Seal ring spare parts kit | For valve and joint maintenance | 1 set |
Attachment Image
![]()
Company Details
Ecer Certification:
Verified Supplier
Our Service Wuhan Mingyang Industrial Technology Co., Ltd. has a professional sales and technical team to deliver premium pre-sales consultation and full technical support. We maintain an efficient after-sales team to timely resolve all product and technical issues for global custome... Our Service Wuhan Mingyang Industrial Technology Co., Ltd. has a professional sales and technical team to deliver premium pre-sales consultation and full technical support. We maintain an efficient after-sales team to timely resolve all product and technical issues for global custome...