Description Feed Through Capacitors RoHS
Mfr. Part # BZMJ 0.45-40-3
Model Number BZMJ 0.45-40-3

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Description Feed Through Capacitors RoHS Mfr. Part # BZMJ 0.45-40-3
Model Number BZMJ 0.45-40-3

BZMJ Series Self-healing Low Voltage Parallel Capacitor

The BZMJ series self-healing low voltage parallel capacitor is designed for power factor improvement and voltage quality enhancement in AC power systems with a rated voltage of 1000V and below. It features a metallic polypropylene film dielectric and rapeseed oil impregnation, offering advantages such as smaller volume, higher reliability, adaptability to higher ambient temperatures and voltage fluctuations, improved sealing, convenient and secure wiring, and a corrosion-resistant metal casing.

Product Attributes

  • Brand: (CHINT)
  • Certifications: GB/T 12747.1-2017, IEC 60831-1:2014; GB/T 12747.2-2017, IEC 60831-2:2014
  • Material: Metallized polypropylene film dielectric, rapeseed oil impregnant
  • Casing: Anti-corrosion metal

Technical Specifications

Model Rated Voltage (kV) Rated Capacity (kvar) Rated Frequency (Hz) Rated Current (A) Capacitance Deviation Loss Tangent (tan) Max Overvoltage (UN) Max Overcurrent (IN) Self-discharge Shell Height H (mm)
BZMJ 0.25-5-1 0.25 5 50/60 20 -5%~+8% 0.0012 (30kvar) / 0.0015 (>30kvar) 1.1 1.3 75V within 3min after 2UN DC 95
BZMJ 0.25-15-1 0.25 15 50/60 60 -5%~+8% 0.0012 (30kvar) / 0.0015 (>30kvar) 1.1 1.3 75V within 3min after 2UN DC 190
BZMJ 0.4-15-3 0.4 15 50/60 21.7 -5%~+8% 0.0012 (30kvar) / 0.0015 (>30kvar) 1.1 1.3 75V within 3min after 2UN DC 190
BZMJ 0.45-30-3 0.45 30 50/60 38.5 -5%~+8% 0.0012 (30kvar) / 0.0015 (>30kvar) 1.1 1.3 75V within 3min after 2UN DC 315
BZMJ 0.48-30-3 0.48 30 50/60 36.1 -5%~+8% 0.0012 (30kvar) / 0.0015 (>30kvar) 1.1 1.3 75V within 3min after 2UN DC 315
BZMJ 0.525-60-3 0.525 60 50/60 66.0 -5%~+8% 0.0015 (>30kvar) 1.1 1.3 75V within 3min after 2UN DC 315
BZMJ 0.69-60-3 0.69 60 50/60 50.2 -5%~+8% 0.0015 (>30kvar) 1.1 1.3 75V within 3min after 2UN DC 315
BZMJ 1.20-40-3 1.20 40 50/60 40.0 -5%~+8% 0.0015 (>30kvar) 1.1 1.3 75V within 3min after 2UN DC 315
BZMJ 0.4-15-3YN 0.4 (Line Voltage) 15 (Total Three-phase Capacity) 50/60 21.7 -5%~+8% 0.0012 (30kvar) / 0.0015 (>30kvar) 1.1 1.3 75V within 3min after 2UN DC 190
BZMJ 0.45-30-3YN 0.45 (Line Voltage) 30 (Total Three-phase Capacity) 50/60 38.5 -5%~+8% 0.0012 (30kvar) / 0.0015 (>30kvar) 1.1 1.3 75V within 3min after 2UN DC 315

Application Scenarios

  • Power factor improvement in AC power systems (rated voltage 1000V).
  • Voltage quality enhancement.
  • Suitable for environments with high ambient temperatures and significant system voltage fluctuations.
  • Requires consideration for harmonic environments; use with anti-harmonic reactors if necessary.
  • Recommended for use with motors (capacitor current < 90% of motor no-load current).
  • Should be disconnected when transformers are no-load.

Notes

  • For phase voltage, divide line voltage by 3 for YN connection.
  • Models with "YN" indicate phase compensation capacitors with a neutral lead.
  • Customization for low-temperature environments (-40~+50) is available.
  • For altitudes above 2000m, consider higher rated voltages (0.48kV for 2000m-3000m, 0.525kV for >3000m).
  • Specialized switches, contactors, electronic composite switches, and overcurrent relays are recommended for systems with parallel capacitors.
  • Capacitors require a 3-minute delay before re-energization and must be short-circuited for discharge after power disconnection.
  • When using miniature circuit breakers for short-circuit protection, select 2-3 times the rated current; avoid closing breakers with capacitors connected. For capacities >30kvar, use RT36 fuses.

2207071901_CHINT-BZMJ-0-45-40-3_C4254631.pdf

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Importer

  • Year Established:

    2009

  • Employee Number:

    >>300

  • Ecer Certification:

    Verified Supplier

.gtr-container-9k2l8p { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; padding: 20px; line-height: 1.6; box-sizing: border-box; max-width: 100%; } .gtr-container-9k2l8p-header { margin-bottom: 20px;... .gtr-container-9k2l8p { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; padding: 20px; line-height: 1.6; box-sizing: border-box; max-width: 100%; } .gtr-container-9k2l8p-header { margin-bottom: 20px;...

+ Read More

Get in touch with us

  • Reach Us
  • Beijing Silk Road Enterprise Management Services Co., Ltd.
  • 16 Floor, Unit B, Jiatai International Mansion, No 41, Dongsihuan Zhong Road, Chaoyang District, Beijing
  • https://www.icpassive.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement