| Description | Feed Through Capacitors RoHS |
| Mfr. Part # | BZMJ 0.45-50-3 |
| Model Number | BZMJ 0.45-50-3 |
View Detail Information
Explore similar products
low voltage self healing parallel capacitor CHINT BZMJ 0.45 40 3 for power
Self Healing Low Voltage Parallel Capacitor CHINT BZMJ 0.4-20-3 with Corrosion
Low voltage parallel capacitor CHINT BZMJ 0.4 30 3 self healing capacitor for
CHINT BZMJ 0.45 10 3 capacitor with corrosion resistant metal casing and
Product Specification
| Description | Feed Through Capacitors RoHS | Mfr. Part # | BZMJ 0.45-50-3 |
| Model Number | BZMJ 0.45-50-3 |
The BZMJ series self-healing low-voltage parallel capacitor is designed for AC power systems with a rated voltage of 1000V and below. It is used to improve power factor and voltage quality. Key features include advanced imported production equipment, high-quality imported polypropylene film for smaller size and greater reliability, unique design for high ambient temperatures and voltage fluctuations, improved sealing, novel installation feet, convenient and safe terminals, and a corrosion-resistant metal casing.
| Series Code | Model | Rated Voltage (kV) | Rated Capacity (kvar) | Rated Frequency (Hz) | Rated Current (A) | Capacitance Deviation | Loss Tangent Value (tan) | Max. Allowable Overvoltage | Max. Allowable Overcurrent | Self-Discharge Characteristic | Housing Height H (mm) | Phase Type | Connection Type |
| BZMJ | BZMJ 0.25-5-1 to BZMJ 0.25-30-1 | 0.25 | 5 to 30 | 50 or 60 | 20 to 1806 | -5%~+8% | 0.0012 (30kvar), 0.0015 (>30kvar) | 1.1UN (8h/24h) | 1.3IN (2h/24h) | 75V within 3min after 2UN DC voltage | 95 to 315 | Single-phase | 1 |
| BZMJ | BZMJ 0.4-1-3 to BZMJ 0.4-60-3 | 0.4 | 1 to 60 | 50 or 60 | 4.3 to 72.7 | -5%~+8% | 0.0012 (30kvar), 0.0015 (>30kvar) | 1.1UN (8h/24h) | 1.3IN (2h/24h) | 75V within 3min after 2UN DC voltage | 95 to 315 | Three-phase | 3 |
| BZMJ | BZMJ 0.45-3-3 to BZMJ 0.45-60-3 | 0.45 | 3 to 60 | 50 or 60 | 6.4 to 691 | -5%~+8% | 0.0012 (30kvar), 0.0015 (>30kvar) | 1.1UN (8h/24h) | 1.3IN (2h/24h) | 75V within 3min after 2UN DC voltage | 95 to 315 | Three-phase | 3 |
| BZMJ | BZMJ 0.48-3-3 to BZMJ 0.48-50-3 | 0.48 | 3 to 50 | 50 or 60 | 6.0 to 553 | -5%~+8% | 0.0012 (30kvar), 0.0015 (>30kvar) | 1.1UN (8h/24h) | 1.3IN (2h/24h) | 75V within 3min after 2UN DC voltage | 95 to 315 | Three-phase | 3 |
| BZMJ | BZMJ 0.525-3-3 to BZMJ 0.525-60-3 | 0.525 | 3 to 60 | 50 or 60 | 5.5 to 693 | -5%~+8% | 0.0012 (30kvar), 0.0015 (>30kvar) | 1.1UN (8h/24h) | 1.3IN (2h/24h) | 75V within 3min after 2UN DC voltage | 95 to 315 | Three-phase | 3 |
| BZMJ | BZMJ 0.69-5-3 to BZMJ 0.69-60-3 | 0.69 | 5 to 60 | 50 or 60 | 6.3 to 945 | -5%~+8% | 0.0012 (30kvar), 0.0015 (>30kvar) | 1.1UN (8h/24h) | 1.3IN (2h/24h) | 75V within 3min after 2UN DC voltage | 95 to 315 | Three-phase | 3 |
| BZMJ | BZMJ 1.20-10-3 to BZMJ 1.20-40-3 | 1.20 | 10 to 40 | 50 or 60 | 14.4 to 48.1 | -5%~+8% | 0.0012 (30kvar), 0.0015 (>30kvar) | 1.1UN (8h/24h) | 1.3IN (2h/24h) | 75V within 3min after 2UN DC voltage | 190 to 315 | Three-phase | 3 |
| BZMJ | BZMJ 3YN (Phased Compensation) | Line voltage (kV) | Total capacity (kvar) | 50 or 60 | -5%~+8% | 0.0012 (30kvar), 0.0015 (>30kvar) | 1.1UN (8h/24h) | 1.3IN (2h/24h) | 75V within 3min after 2UN DC voltage | Three-phase | YN (Star connection, neutral lead out) |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer
Year Established:
2009
Employee Number:
>>300
Ecer Certification:
Verified Supplier
.gtr-container-9k2l8p { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; padding: 20px; line-height: 1.6; box-sizing: border-box; max-width: 100%; } .gtr-container-9k2l8p-header { margin-bottom: 20px;... .gtr-container-9k2l8p { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; padding: 20px; line-height: 1.6; box-sizing: border-box; max-width: 100%; } .gtr-container-9k2l8p-header { margin-bottom: 20px;...
Get in touch with us
Leave a Message, we will call you back quickly!