| Payment Terms | L/C, T/T |
| Supply Ability | 5000 units per month for small parts. 1000 units per month for large parts |
| Delivery Time | 7 - 15 days for small orders, 15 - 30 days for large orders |
| Packaging Details | Customized packaging to protect products |
| Type | Straight-through cage-type cast globe valve |
| Nominal diameter | 40~200mm |
| Nominal pressure | ANSI 900, 1500, 2500; JIS 63K |
| Connection type | Flanged: RF, RJ Standards: ANSI B 16.5; JIS B2201 Welded: Socket weld (SW) (40~80mm); Butt weld (BW) (80~200mm) |
| Materials | ZG25, ZG1Cr18Ni9, ZG0Cr17Ni12Mo2, 1.25Cr0.5Mo, 2.25Cr1.0Mo, 5.0Cr0.5Mo, SCPH21, SCPH32, SCPH61 |
| Upper valve bonnet | Normal temperature type (P): -5~+230℃ Extended type Ⅰ (E1): +230~+566℃ |
| Gland type | Bolt-clamped type |
| Packing | Asbestos braided packing |
| Brand Name | WEYO |
| Model Number | HPC |
| Place of Origin | China |
View Detail Information
Explore similar products
HPAS High Pressure Single Seat Angle Valve Pneumatic Proportional Valve
HTC Boiler Feed Pump Minimum Flow Control Valve 50mm 65mm 80mm 100mm Nominal
ZS A B T Type Pneumatic Piston Diaphragm Valve Corrosion Resistant
HPAC High Pressure Cage Type Cast Angle Valve ANSI 900 1500 2500 JIS 63K
Product Specification
| Payment Terms | L/C, T/T | Supply Ability | 5000 units per month for small parts. 1000 units per month for large parts |
| Delivery Time | 7 - 15 days for small orders, 15 - 30 days for large orders | Packaging Details | Customized packaging to protect products |
| Type | Straight-through cage-type cast globe valve | Nominal diameter | 40~200mm |
| Nominal pressure | ANSI 900, 1500, 2500; JIS 63K | Connection type | Flanged: RF, RJ Standards: ANSI B 16.5; JIS B2201 Welded: Socket weld (SW) (40~80mm); Butt weld (BW) (80~200mm) |
| Materials | ZG25, ZG1Cr18Ni9, ZG0Cr17Ni12Mo2, 1.25Cr0.5Mo, 2.25Cr1.0Mo, 5.0Cr0.5Mo, SCPH21, SCPH32, SCPH61 | Upper valve bonnet | Normal temperature type (P): -5~+230℃ Extended type Ⅰ (E1): +230~+566℃ |
| Gland type | Bolt-clamped type | Packing | Asbestos braided packing |
| Brand Name | WEYO | Model Number | HPC |
| Place of Origin | China | ||
| High Light | Cage regulation valve ,High Pressure regulation valve ,HPC hydraulic proportional pressure control valve | ||
The HPC high-pressure cage-type control valve is a pressure-balanced control valve. The fluid channel of the valve body is in an S-shaped streamline design, featuring small pressure drop loss, large flow rate, and a wide adjustable range. Equipped with a multi-spring diaphragm actuator, the valve has a compact structure and large output force. It is widely applicable to high-pressure drop occasions requiring good dynamic stability, low noise, and little cavitation corrosion.
CV value and stroke See Table 1 Table 1
| Nominal diameter(mm) | 40 | 50 | 80 | 100 | 150 | 200 | ||||||||||||||
| Valve seat diameter (mm) | 25 | 32 | 40 | 32 | 40 | 50 | 50 | 65 | 80 | 65 | 80 | 100 | 100 | 125 | 150 | 125 | 150 | 200 | ||
| Rated | Equal percentage | ANSI900 1500 JIS63K | 12 | 17 | 25 | 17 | 25 | 52 | 52 | 78 | 110 | 78 | 110 | 180 | 180 | 270 | 375 | 270 | 375 | 650 |
| ANSI2500 | - | 12 | 17 | 12 | 17 | 31 | 31 | 52 | 78 | 52 | 78 | 125 | 125 | 180 | 270 | 180 | 270 | 470 | ||
| Linear | ANSI900 1500 JIS63K | 12 | 20 | 30 | 20 | 30 | 62 | 62 | 90 | 135 | 90 | 135 | 210 | 210 | 330 | 485 | 330 | 485 | 700 | |
| ANSI2500 | - | 12 | 20 | 12 | 20 | 43 | 43 | 62 | 90 | 62 | 90 | 150 | 150 | 210 | 330 | 210 | 330 | 520 | ||
| Rated stroke (mm) | 25 | 38 | 50 | 75 | ||||||||||||||||
Allowable differential pressure
Equipped with HA or VA actuator broussonetia papyrifera (with positioner) See Table 2, 3
Air-to-close valve Table 2
| Nominal pressure | Actuator | Gas supply Pressure (MPa) | Spring range (MPa) | Allowable pressure difference (MPa) | |||||
| Nominal diameter (mm) | |||||||||
| 40 | 50 | 80 | 100 | 150 | 200 | ||||
| ANSI900 1500 JIS63K | HA3D | 0.28 | 0.04-0.20 | 15.3 26.4 | 11.6 19 | 7.8 11.3 | 5.8 7.4 | - | - |
| 0.3 | 15.3 26.4 | 11.6 24.8 | 7.8 15.2 | 5.8 10.3 | - | - | |||
| 0.35 | 0.08-0.24 | 26.1 26.4 | 23.3 26.4 | 15.6 17.2 | 11.7 11.8 | 6.4 | - | ||
| 0.4 | 26.4 26.4 | 23.3 26.4 | 15.6 26.4 | 11.7 19.1 | 7.8 11.7 | - | |||
| HA4D | 0.28 | 0.04-0.20 | 21.1 26.4 | 20.1 26.4 | 13.5 22.7 | 10.1 15.9 | 6.7 9.1 | 5.0 5.7 | |
| 0.3 | 26.3 26.4 | 20.1 26.4 | 13.5 26.4 | 10.1 21 | 6.7 12.5 | 5.0 8.3 | |||
| 0.35 | 0.08-0.24 | - | 26.4 | 26.4 | 20.2 23.5 | 13.5 14.2 | 9.5 | ||
| 0.4 | - | - | - | 20.2 26.4 | 13.5 22.6 | 10.1 15.8 | |||
| VA5D | 0.28 | 0.04-0.20 | - | - | - | 13.8 23.4 | 9.2 14.1 | 6.9 9.5 | |
| ANSI 2500 | HA3D | 0.28 | 0.04-0.20 | 15.3 26.4 | 11.6 19 | 10.6 16.9 | 7.1 9.9 | 4.4 4.5 | - |
| 0.3 | 15.3 33.9 | 11.6 24.8 | 10.6 22.2 | 7.1 13.5 | 4.4 6.7 | ||||
| 0.35 | 0.08-0.24 | 26.1 37.7 | 23.3 27.7 | 21.2 24.9 | 14.2 15.3 | 7.8 | - | ||
| 0.4 | 30.6 44 | 23.3 42.3 | 21.2 38.1 | 14.2 24.2 | 8.8 13.4 | - | |||
| HA4D | 0.28 | 0.04-0.20 | 21.1 44 | 20.1 35.9 | 18.3 32.4 | 12.3 20.3 | 7.6 11 | 6.7 9.1 | |
| 0.3 | 26.3 44 | 20.1 44 | 18.3 41.5 | 12.3 26.5 | 7.6 14.8 | 6.7 12.5 | |||
| 0.35 | 0.08-0.24 | 28.9 44 | 28.9 44 | 28.9 44 | 24.6 29.5 | 15.3 16.7 | 13.5 14.2 | ||
| 0.4 | 42 44 | 40.3 44 | 36.7 44 | 24.6 44 | 15.3 26.3 | 13.5 22.6 | |||
| VA5D | 0.28 | 0.04-0.20 | - | - | - | 16.8 29.4 | 10.4 16.6 | 9.2 14.1 | |
Notes: 1. The numbers in the dark-colored boxes indicate the standard specifications for valve actuators—Broussonetia papyrifera.
2. The allowable pressure difference condition when the valve is closed is ΔP=P1 (P2=0), and the pressure difference at full closure varies slightly with different outlet pressures P2.
3. The maximum allowable pressure difference must not exceed the maximum value specified in ANSI B16.34 or JIS B2201.
4. The inlet pressure P1 must not exceed the allowable pressure difference when closed.
5. In the same cell, the upper number indicates the allowable pressure difference when the valve is fully open, and the lower number indicates the allowable pressure difference when fully closed.
B. Gas - Open Valve Table 3
| Nominal pressure | Execute Organization | Gas supply Pressure (MPa) | Spring range (MPa) | Allowable pressure difference (MPa) | |||||
| Nominal diameter (mm) | |||||||||
| 40 | 50 | 80 | 100 | 150 | 200 | ||||
| ANSI900 1500 JIS63K | HA3R | 0.28 | 0.08-0.24 | 15.3 26.4 | 11.6 19 | 7.8 11.3 | 5.8 7.4 | - | - |
| 0.3 | 19 26.4 | 17.5 19 | 11.3 | 7.4 | - | - | |||
| 0.35 | - | 18.9 19 | - | - | - | - | |||
| HA4R | 0.28 | 0.08-0.24 | 21.1 26.4 | 20.1 26.4 | 13.5 22.7 | 10.1 15.9 | 6.7 9.1 | 5. 5.7 | |
| 0.3 | - | 21 26.4 | 20.3 22.7 | 15.2 15.9 | 9.1 | 5.7 | |||
| 0.35 | - | - | 21 22.7 | 15.9 | - | - | |||
| VA5R | 0.28 | 0.08-0.24 | - | - | - | 13.8 23.4 | 9.2 14.1 | 6.9 9.5 | |
| VA6R | 0.5 | 0.19-0.35 | - | - | - | 26.4 | - | - | |
| 0.5 | 0.19-0.40 | - | - | - | - | 19.1 26.4 | - | ||
| ANSI 2500 | HA3R | 0.28 | 0.08-0.24 | 15.3 26.4 | 11.6 19 | 10.6 16.9 | 7.1 9.9 | 4.4 4.5 | - |
| 0.3 | 19 26.4 | 17.5 19 | 15.9 16.9 | 9.9 | 4.4 4.5 | - | |||
| 0.35 | - | 18.9 19 | 16.9 | - | - | - | |||
| HA4R | 0.28 | 0.08-0.24 | 21.1 44 | 20.1 35.9 | 18.3 32.4 | 12.3 20.3 | 7.6 11 | 6.7 9.1 | |
| 0.3 | - | 21 35.9 | 21 32.4 | 18.4 20.3 | 11 | 9.1 | |||
| 0.35 | - | - | - | 20.3 | - | - | |||
| VA5R | 0.28 | 0.08-0.24 | - | - | - | 16.8 29.4 | 10.4 16.6 | 9.2 14.1 | |
| VA6R | 0.4 | 0.19-0.35 | - | - | - | 36.2 44 | - | - | |
| 0.5 | 0.19-0.40 | - | - | - | - | 21.6 36.8 | - | ||
Equipped with VP executive machine broussonetia papyrifera (with positioner) see Table 4 Table 4
| Nominal pressure | Actuator | Nominal diameter (mm) | Gas supply pressure MPa) | ||
| 0.3 | 0.4 | 0.5 | |||
| ANSI9001500JIS63K | VP5 | 150 | 19.8 24.2 | 26.4 | 26.4 |
| ANSI2500 | 19.8 28.1 | 26.4 38.9 | 33 44 | ||
| ANSI9001500JIS63K | VP6 | 200 | 19.1 26.4 | 25.5 26.4 | 26.4 |
| ANSI2500 | 19.2 44 | 25.5 44 | 31.9 44 | ||
Notes: 1. If the actuator broussonetia papyrifera is equipped with an auxiliary air source, the smaller of the two supply pressures should be selected as the basis for calculating the allowable pressure difference.
2. The condition for the allowable pressure difference when the valve is closed on the table is △P=P1 (P2=0). The pressure difference when fully closed varies slightly with different outlet pressures P2.
3. The maximum allowable pressure difference must not exceed the maximum value specified in ANSI B16.34 or JIS B2201.
4. The inlet pressure P1 must not exceed the allowable pressure difference when closed.
5. In the same cell, the upper number indicates the allowable pressure difference when the valve is fully open, and the lower number indicates the allowable pressure difference when fully closed.
![]()
Equipped with HA execution machine broussonetia papyrifera
Equipped with VA5 execution machine broussonetia papyrifera
Equipped with VA6 execution machine broussonetia papyrifera
Equipped with VP execution machine broussonetia papyrifera
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2003
Total Annual:
141790014-161450000
Employee Number:
1000~1200
Ecer Certification:
Verified Supplier
High-End Die-Shanghai WEYO Automation Technology Co., Ltd. was established in 2021 and is headquartered in Shanghai. It is an innovative technology enterprise that specializes in high-end industrial automation equipment, core components supply, technical services, and solution provision. With the co... High-End Die-Shanghai WEYO Automation Technology Co., Ltd. was established in 2021 and is headquartered in Shanghai. It is an innovative technology enterprise that specializes in high-end industrial automation equipment, core components supply, technical services, and solution provision. With the co...
Get in touch with us
Leave a Message, we will call you back quickly!