China High Precision Gas Analysis System Explosion Proof Gas Tester For O2 CO CO2 CH4
China High Precision Gas Analysis System Explosion Proof Gas Tester For O2 CO CO2 CH4

  1. China High Precision Gas Analysis System Explosion Proof Gas Tester For O2 CO CO2 CH4
  2. China High Precision Gas Analysis System Explosion Proof Gas Tester For O2 CO CO2 CH4
  3. China High Precision Gas Analysis System Explosion Proof Gas Tester For O2 CO CO2 CH4

High Precision Gas Analysis System Explosion Proof Gas Tester For O2 CO CO2 CH4

  1. MOQ: 1
  2. Price: Negotiable
  3. Get Latest Price
type Multi-Gas Detector
Accuracy Class High Accuracy
Delivery Time appointed time
Supply Ability Supply Ability: >10000 Sets Per Year
Payment Terms L/C、D/A、D/P、T/T
Target Gas Multi-Gas
Alarm Mode Sound
Packaging Details Export Standard
Place of Origin Xi'an, Shaanxi, China
Brand Name Runlai
Certification ISO certification
Model Number 609

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

type Multi-Gas Detector Accuracy Class High Accuracy
Delivery Time appointed time Supply Ability Supply Ability: >10000 Sets Per Year
Payment Terms L/C、D/A、D/P、T/T Target Gas Multi-Gas
Alarm Mode Sound Packaging Details Export Standard
Place of Origin Xi'an, Shaanxi, China Brand Name Runlai
Certification ISO certification Model Number 609
High Light Gas Analysis System Explosion Proof ,CH4 Gas Analysis System

Test Gas Technical Parameters

O2 Measurement Principle: Electrochemical principle;

Measurement Range: 0~10/100/1000 ppm (range can be selected arbitrarily)

Accuracy:

  • ≤±3% F.S (0~10 ppm)
  • ≤±2% F.S (0~100 ppm)
  • ≤±2% F.S (0~1000 ppm)

Repeatability: ≤±1% FS;

Stability: ≤±1% FS;

Response Time: T90 ≤ 10 seconds

Sample Gas Flow Rate: 3L/min;

Control Output: Relay contact output, which can be set by the user arbitrarily;

Contact Capacity: 220VAC, 2A/24VDC, 1A;

Analog Output: 4~20mA (specify during order);

Communication Output: RS-232 or RS-485 (specify during order);

Overall System Parameters

The Explosion-Proof Grade of the Analyzer: not explosion-proof

Detection Principle: electrochemical

Installation Method: extraction type installation

Outdoor installation of the instrument cabinet, carbon steel spray painting, corrosion-resistant in line with the buyer's on-site working conditions

Cabinet and Pipe Fittings, Sampling Part of the Analysis Instrument, Gas Path Part, and Contact Liquid Part: 316S stainless steel or corrosion-resistant material with copper and zinc content < 3%

Installation Position: extraction type installation on site

Monitoring Items: oxygen

Attached Measurement Parameters: 0~10 ppm/10~100 ppm/100~1000 ppm

In/Out Gas Interface: φ6 socket interface or φ8 socket interface

Key Features

  • RL-609 oxygen process complete analysis system is a high-precision online gas detection and analysis system developed by our company. This instrument adopts imported high-precision oxygen sensors combined with single-chip microcomputer control technology, featuring high measurement accuracy and simple operation;
  • Internal instrument uses high-performance TFT color display screen, which can simultaneously display measurement values, range, status, and various parameter setting interfaces;
  • All Chinese operation, can configure, calibrate, test various instrument parameters, historical records can be set according to time;
  • New gas path pre-treatment system: has technical, high precision, fast response, stable performance, continuous gas analysis process advantages, the analyzer is equipped with a precise filter inside, each analyzer can enter the sampling detection state or the maintenance/calibration state independently;
  • 4-20mA analog output: the analyzer can output 4-20mA analog output signals corresponding to each sampling sample gas range, providing synchronous data transmission to the terminal system;
  • Control output: the analyzer can intelligently control multi-contact relays, which can output concentration upper and lower limit alarm signals, calibration/maintenance status and sampling status switching signals;

Applications

Used for online detection of oxygen content in hydrogen production, chemical processes, new energy materials, etc.;

  1. coal-fired power plant emission monitoring;
  2. cement plant emission monitoring
  3. industrial kiln emission monitoring
  4. air separation industry;
  5. metallurgical industry;
  6. new energy materials.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2018

  • Total Annual:

    >Over 5 million dollars

  • Employee Number:

    >More than 150 peopl

  • Ecer Certification:

    Verified Supplier

Xi'an Runlai Instrument Co., Ltd. is a company specializing in the research, development, production, sales, and service of gas analysis technology and instruments. We have a team of professionals with long-term experience in gas analysis instrumentation, making us a technology-driven manufacturer... Xi'an Runlai Instrument Co., Ltd. is a company specializing in the research, development, production, sales, and service of gas analysis technology and instruments. We have a team of professionals with long-term experience in gas analysis instrumentation, making us a technology-driven manufacturer...

+ Read More

Get in touch with us

  • Reach Us
  • Xi'an Runlai Instrument Co., Ltd.
  • Room 403, Building 3, Zhongxing Deep Blue Technology Industrial Park, Fengdong New City, Xi'an, Shaanxi Province
  • https://www.industrialgasanalyzer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement