China Indenter Lifting Structure Automatic Micro Vickers Hardness Tester JMHVS-1000XYZ
China Indenter Lifting Structure Automatic Micro Vickers Hardness Tester JMHVS-1000XYZ

  1. China Indenter Lifting Structure Automatic Micro Vickers Hardness Tester JMHVS-1000XYZ

Indenter Lifting Structure Automatic Micro Vickers Hardness Tester JMHVS-1000XYZ

  1. MOQ: 1 Set
  2. Price:
  3. Get Latest Price
Payment Terms T/T
Supply Ability 10 Sets per Month
Delivery Time 20 Working Days
Packaging Details Plywood Pallet
Movement Control supports XY motorized sample stage movement and Z-axis control
Variable Speed When the platform moves, five speed levels are available
special function Arbitrary origin setting, automatic reset, mechanical limits
Automatic Operation system automatically moves along a preset multi-point path, automatically rotates the turret
Hardness conversion convert measured micro Vickers hardness values into other hardness scales
Position Loading Drag the stage with the mouse to move in any direction, allowing the user to view the sample surface
Brand Name iqualitrol
Model Number JMHVS-1000XYZ
Certification
Place of Origin

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 10 Sets per Month
Delivery Time 20 Working Days Packaging Details Plywood Pallet
Movement Control supports XY motorized sample stage movement and Z-axis control Variable Speed When the platform moves, five speed levels are available
special function Arbitrary origin setting, automatic reset, mechanical limits Automatic Operation system automatically moves along a preset multi-point path, automatically rotates the turret
Hardness conversion convert measured micro Vickers hardness values into other hardness scales Position Loading Drag the stage with the mouse to move in any direction, allowing the user to view the sample surface
Brand Name iqualitrol Model Number JMHVS-1000XYZ
Certification Place of Origin
High Light Non Destructive Testing Equipment CEPortable Non Destructive Testing EquipmentDigital Soil Moisture Meter

 

Indenter Lifting Structure Automatic Micro Vickers Hardness Tester JMHVS-1000XYZ

 

Download Technical Data: Micro Vickers Hardness Tester JMHVS-1000XYZ

 

Brief Introduction:

The iqualitrol JMHVS-1000XYZ Automatic Precision micro Vickers Hardness Tester equips with indenter lifting structure. It is especially suitable for the testing of large-sized workpieces. Moreover, it has good reliability, operability and intuition.

 

JMHVS-1000XYZ adopts computer software programming, high-power optical measurement system and closed-loop control technology of sensors.

 

JMHVS-1000XYZ equipped with indentation image automatic analysis system, which can not only photograph and measure the indentation and observe metallographic structure of materials, but also measure the depth of hardened layer of workpiece by planning path.

 

It is suitable for measuring Vickers hardness thin specimens, surface coating and other brittle materials such as glass, ceramics, agate, gemstone, etc.

 

Technical Specifications:

Model JMHVS-1000XYZ
Test Forces 10gf, 25gf, 50gf, 100gf, 200gf, 300gf, 500gf, 1kgf
0.098N, 0.245N, 0.49N, 0.98N, 1.96N, 2.94N, 4.9N, 9.8N
Executive Standards GBT4340, ISO 6507, ASTM E92
Loading Control Automatic loading, dwell and unloading
XY Platform and Z axis

Motorized XY platform and Z axis focusing:

1, XY travel 50mm*50mm, size 200mmX180mm, repeatability< 2um, XY Z movement resolution 2um

2, Speed is adjustable for XY Z movement

3, Click the mouse to control movement, or by entering the distance to move;

4, Support the movement by joystick, provide timely feedback on mobile location

Loading Mode and Path Settings

Multiple methods ensure users can still obtain satisfactory measurement results even when the sample placement is not vertical or horizontal.

Two-point method: Click any two points on the sample image to specify the movement direction of the stage;
Normal method: Select the normal to the sample edge to determine the stage movement direction;
Angle bisector: Choose an angle, and use the direction of its bisector as the sample movement direction;
Arbitrary point method: Place the moving platform at any position, add a loading point, and then perform a single loading and measurement.
Arbitrary point loading: Double-click any position on the platform, and the platform will automatically move that point to the center of the indenter's field of view to load and measure.
Path adjustment: For the selected path, various operations can be performed, including horizontal mirror, vertical mirror, 90-degree rotation, 180-degree rotation, rotation at any angle, and position translation.

Automatic measurement Automatically load point by point along the set loading path, automatically focus, and automatically measure indents to calculate hardness values, and plot the hardening curve;
Camera and Calibration

1, 3MP USB CMOS Camera;

2, support calibration by hardness blocks and micrometers

3, In order to improve measurement accuracy, different test forces can be calibrated separately, and the system loads them automatically.

Hardness conversion and compensation Conform ASTM E140
Data Statistics Automatically calculate average hardness, variance, etc.
Measurement Algorithm 1. Leading automatic reading technology — The leading automatic reading technology not only provides sub-pixel, high-precision, and high-repeatability results, but is also suitable for general indentation images, including those with slight rust, scratches, uneven lighting, or mild corrosion, with an extremely fast measurement speed;
2. Unique manual point selection and automatic point-finding technology — Users can roughly select points near the four corners of the indentation, and the system automatically determines the best corner positions for direct reading; this meets the habits of general users while greatly reducing their workload;
3. General manual measurement methods — Including 4-corner measurement, 2-diagonal measurement, etc. For 4-corner measurement, the four corners can be selected in any order, making it convenient for users.
Hardening curve Automatically plot hardening curve
Data Storage Original measurement data and images can be saved in the document for later retrieval and report printing; one file saves all the data of one measurement.
Test Report Automatically generate WORD or EXCEL document reports; report formats can be customized; standard formats include hardness values for each measurement point, statistical values, indentation images, and hardening curves, etc.
Knoop Hardness Support Knoop hardness test
Resolution 0.01μm
Hardness range 5-3000HV
Magnifications 100X
400X
Turret Auto Turret
Conversion Scales HRHBHV
Dwell Time 5-60 seconds
X-Y anvil Size: 100*100mm, travel: 25*25mm
Vertical space 180mm
Depth throat 110mm
Power supply AC220V±5%, 50-60Hz
Dimension 490*350*540mm
Weight 60kg

 

Main Features:

1, XYZ Sample Movement Control: The system supports XY motorized sample stage movement and Z-axis control; including manual control, motorized control (joystick control), and automatic control (software control). X-Y directions can move synchronously. Motorized control uses a three-dimensional joystick, designed based on ergonomic principles, simple and convenient, and operates at will.

2, Software Control and Loading Modes:
2.1, Positioning Movement Loading: The stage moves directly to the software-set position for loading.
2.2, Fixed-Point Movement Loading: Select any point on the sample, move it under the indenter, and load.
2.3, Directional Movement Loading: Use mouse clicks to control the stage to move in any of eight directions; movement step size can be set and load applied.
2.4, Arbitrary Position Loading: Drag the stage with the mouse to move in any direction, allowing the user to view the sample surface; a loading point can be set at any position.

3, Variable Speed Movement: When the platform moves, five speed levels are available.


4, Other Functions: Arbitrary origin setting, automatic reset, mechanical limits, and other professional functions to meet various requirements.


5, Fully Automatic Operation: The system automatically moves along a preset multi-point path, automatically rotates the turret, automatically loads, automatically focuses, and automatically measures, while automatically plotting the hardening curve.

6, Hardness Value Conversion, Correction, and Effective Verification: The system can convert measured micro Vickers hardness values into other hardness scales such as HB, HR, etc.; it can also effectively verify sample measurement values.

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler

  • Year Established:

    2010

  • Total Annual:

    1000000-1500000

  • Employee Number:

    10~30

  • Ecer Certification:

    Site Member

  iqualitrol is a professional company to supply quality control instrument and repair service. The main products are industrial video borescope, hardness testers, metallographical instrument, metallurgical microscopes, temperature test chambers, etc.   These are widely used ...   iqualitrol is a professional company to supply quality control instrument and repair service. The main products are industrial video borescope, hardness testers, metallographical instrument, metallurgical microscopes, temperature test chambers, etc.   These are widely used ...

+ Read More

Get in touch with us

  • Reach Us
  • Dongguan Quality Control Technology Co., Ltd.
  • Room 301, Building No.1, No. 2 Jiaolian Yiheng Rd, Wanjiang District, Dongguan, China, 523046
  • https://www.iqualitrol.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement