| Payment Terms | L/C,D/A,D/P,T/T,Western Union |
| Supply Ability | 5000-10000 pieces/mouth |
| Delivery Time | 7-15 days |
| Packaging Details | box |
| Model | LPM 40-385/4 / LPM 50-385/4 / LPM 80-385/4 / LPM 100-385/4 |
| SPD Type | T2 (IEC 61643.11) |
| Nominal Operating Voltage (Un) | 230Vac(50Hz) |
| Maximum Continuous Operating Voltage (Uc) | 385Vac(50Hz) |
| Nominal Discharge Current (In) | 40kA/50kA/80kA/100kA |
| Maximum Discharge Current (Imax) | 80kA/100kA/160kA/200kA |
| Voltage Protection Level (Up) | ≤2.0kV / ≤2.2kV / ≤2.2kV / ≤2.2kV |
| Response Time | ≤25ns |
| Brand Name | LLH |
| Model Number | LPM 40-385/4 |
| Place of Origin | Guangdong Province.China |
View Detail Information
Explore similar products
Whole House Surge Protector 3 Phase 220V 30kA 65kA Office Building Power
Electrical SPD T2 AC SPD 3 Phase 220V 385V 30kA 65kA For Home Use
Surge Voltage Arrester 3 Phase 220V 385V 40kA 80kA Home Lightning Surge
Type 2 Surge Protection Device 3 Phase 220V 385V 40kA 80kA For Electrical Panel
Product Specification
| Payment Terms | L/C,D/A,D/P,T/T,Western Union | Supply Ability | 5000-10000 pieces/mouth |
| Delivery Time | 7-15 days | Packaging Details | box |
| Model | LPM 40-385/4 / LPM 50-385/4 / LPM 80-385/4 / LPM 100-385/4 | SPD Type | T2 (IEC 61643.11) |
| Nominal Operating Voltage (Un) | 230Vac(50Hz) | Maximum Continuous Operating Voltage (Uc) | 385Vac(50Hz) |
| Nominal Discharge Current (In) | 40kA/50kA/80kA/100kA | Maximum Discharge Current (Imax) | 80kA/100kA/160kA/200kA |
| Voltage Protection Level (Up) | ≤2.0kV / ≤2.2kV / ≤2.2kV / ≤2.2kV | Response Time | ≤25ns |
| Brand Name | LLH | Model Number | LPM 40-385/4 |
| Place of Origin | Guangdong Province.China | ||
| High Light | Whole House Surge Protection Device 220V ,3 Phase Surge Protection Device ,Whole Home Surge Protector 50KA | ||
LPM 40-385/4 Series is a T2 level power surge protector designed for three-phase power supply systems. It is specifically tailored for industrial and commercial power systems, providing reliable protection against transient overvoltages caused by lightning strikes and power grid fluctuations.
Product features
|
● Independent integrated module for each pole
|
|
● Built-in ultra-low temperature release mechanism
|
|
● Equipped with indication windows and remote signaling contacts
|
| ● Application scenarios:Suitable for installation in LPZ 0B-1 and subsequent lightning protection zones, used as lightning arrester for wind powergeneration systems. |
Product Features
![]()
| Standards | IEC 61643-11 |
| SPD type | T2 |
| Models |
LPM 40-385/4 LPM 50-385/4 LPM 80-385/4
LPM 100-385/4
|
| Nominal operating voltage Un | 230Vac(50Hz) |
| Maximum continuous operating voltage Uc | 385Vac(50Hz) |
| Nominal discharge current (8/20μs)In | 40kA/50kA/80kA/100kA |
| Maximum discharge current (8/20μs) Imax | 80kA/100kA/160kA/200kA |
| Voltage protection level In@Up | ≤2.0kV/≤2.2kV/≤2.2kV/≤2.2kV |
| Response time tA | ≤25ns |
| Protection Circuit | L1,L2,L3,N-E |
Mechanical parameters
| Installation method | DIN Rail 35mm |
| Screw torque | 5N*m |
| Strip length | 12mm |
| Wiring cross-sectional area | 2.5mm²-32mm² |
| Product size | 90mmx144mmx68mm |
| Shell material and flame retardant grade | Mineral nylon PA6, V0 |
| Deterioration indication | Window red: Fail |
| Remote signaling contact type | Normally closed and normally open switching contacts |
| Remote signaling contact switching ability | 125Vac/1A,125Vdc/0.2A |
| Maximum connection capacity of remote signaling | 2.5mm² |
Notices
● Install the SPD in LPZ 0B-1 or subsequent lightning protection zones to ensure effective T2 protection.
● Use wiring with cross-sectional area 2.5mm²-32mm² and tighten screws to 5N·m torque.
● Regularly check the indication window—replace the product immediately if it turns red (failure status).
● Ensure the grounding system meets requirements (ground resistance ≤4Ω) for optimal surge diversion.
● Select the appropriate model based on the required discharge current (40kA/50kA/80kA/100kA).
● Avoid using the product beyond the specified temperature (-40℃~+80℃) and humidity range.
FAQ
Q1: What is the difference between the models in the series?
A1: The main difference is nominal discharge current (In) and maximum discharge current (Imax): LPM 40-385/4 (40kA/80kA), LPM 50-385/4 (50kA/100kA), LPM 80-385/4 (80kA/160kA), LPM 100-385/4 (100kA/200kA).
Q2: Does the product support remote monitoring?
A2: Yes, it is equipped with normally closed and normally open remote signaling contacts, enabling connection to monitoring systems for remote status tracking.
Q3: What is the function of the built-in ultra-low temperature release mechanism?
A3: It ensures the product operates safely in low-temperature environments (-40℃) and disconnects faulty modules to avoid hazards.
Q4: Can it be used in 400V three-phase systems?
A4: Yes, with maximum continuous operating voltage 385Vac, it is compatible with 400V three-phase systems (230V phase-neutral).
Q5: What is the flame-retardant grade of the housing?
A5: The housing is made of mineral nylon PA6 with V0 flame-retardant grade, which self-extinguishes within 10 seconds after ignition.
Company Details
Business Type:
Manufacturer
Year Established:
2018
Total Annual:
1000000-10000000
Employee Number:
20~100
Ecer Certification:
Verified Supplier
Shenzhen Leilihai Electric Co., Ltd We are a high-tech enterprise that integrates the research and development, manufacturing, sales, and installation services of lightning protection devices and lightning protection system supporting products. The company has successively passed the German TUV cer... Shenzhen Leilihai Electric Co., Ltd We are a high-tech enterprise that integrates the research and development, manufacturing, sales, and installation services of lightning protection devices and lightning protection system supporting products. The company has successively passed the German TUV cer...
Get in touch with us
Leave a Message, we will call you back quickly!