MatyLink DSP-100B is a protocol conversion gateway that brings Modbus RTU field equipment into a BACnet building automation system. On the Modbus side the gateway works as a master, polling downstream slave devices on two RS485 ports (up to 8 slaves per port). On the BACnet side it works as a server, presenting up to 256 points to the head-end as standard BACnet objects. No gateway software is needed: channels, devices and points are configured from a built-in web page in any browser.
.m2b / .json) and a built-in real-time clock/log, 2048 entries retained after power loss) and run-time log (/ramlog, last 64 entries) for after-sales diagnosis| Model | DSP-100B |
| Function | Modbus RTU to BACnet protocol conversion gateway |
| Modbus RS485 ports | 2 x RS485, master |
| Max. slaves per port | 8 |
| Max. BACnet points | 256 |
| Modbus baud rate | 2400–115200 bit/s (web presets: 9600 / 19200 / 38400 / 57600 / 115200) |
| Modbus serial format | Data bits 7/8, stop bits 1/2, parity N/O/E |
| Modbus slave address | 1–247, unique within a port |
| Modbus function codes | 01, 02, 03, 04, 05, 06, 15, 16 |
| Point data types | Bool, Word, Short, DWord, Long, Float, Double; byte order configurable for word/dword/float |
| Polling parameters | Response timeout 200 ms default; polling period 1000 ms default (configurable per channel) |
| BACnet data link | BACnet/IP or BACnet MS/TP (one at a time, effective after restart) |
| BACnet/IP | UDP 47808 (configurable); configurable device instance |
| BACnet MS/TP | Dedicated RS485 port; MAC 0–127; 9600–115200 bit/s, default 76800 bit/s |
| BACnet objects | Device, AI, AO, AV, BI, BO, BV (AO/AV/BO/BV Present_Value writable) |
| BACnet APDU | 480 B, no segmentation; 20–25 objects per ReadPropertyMultiple recommended |
| Ethernet | 1 x RJ45, 10/100 Mbps (BACnet/IP and web configuration) |
| Supply / power | AC/DC 9–24 V; less than 3 W |
| Default network | 192.168.0.88/24, gateway 192.168.0.1, HTTP port 80 (restored by factory reset) |
| Enclosure | Metal housing; 97.96 mm x 125.98 mm; 30 mm mounting ears each side (approx. 157.96 mm overall width) |
| Mounting | DIN rail |
| Terminals | Pluggable green terminals (mating plugs supplied) |
| Operating temperature | -20 °C to +70 °C |
| Operating humidity | 0% to 95% RH, non-condensing |
| RS485 cable length | Up to 1000 m |
| Ethernet cable length | Cat 5 or better, up to 150 m |
| Sample cycle | Approx. 1.5 s (bench reference: 20 points, one channel at 9600 8N1, 1000 ms polling) |
| Marking | CE, FCC, RoHS marked on the housing (certificate documents on request) |
| Model | Modbus RS485 ports | Max. slaves per port | Max. BACnet points | Supply / power |
| QSP-400B | 4 x RS485 | 32 slaves | 1024 | AC/DC 9–24 V, < 3 W |
| QSP-800B | 4 x RS485 | 32 slaves | 2048 | AC/DC 9–24 V, < 3 W |
| DSP-200B | 2 x RS485 | 32 slaves | 512 | AC/DC 9–24 V, < 3 W |
| DSP-100B (this model) | 2 x RS485 | 8 slaves | 256 | AC/DC 9–24 V, < 3 W |
The three-digit number in the model name is a series code, not a point count: QSP models have four RS485 ports, DSP models have two. All four models share the same BACnet object types, service set and web configuration method; they differ only in Modbus port count, slaves per port and maximum point capacity.
Typical downstream equipment includes electricity meters, flow meters, lifts and escalators, variable frequency drives, central-plant chillers, heating boilers and water supply / drainage equipment. The gateway only collects Modbus data and converts it to BACnet objects; it does not drive fans, pumps or valves directly – start/stop and modulation stay with the existing controllers or head-end.
192.168.0.88, mask 255.255.255.0, gateway 192.168.0.1; open http://192.168.0.88 in a browser to configure./log and contact the supplier.Standard supply: gateway unit, mating pluggable terminals and accompanying documents. BACnet/IP or BACnet MS/TP is selected by software configuration and does not change the hardware model. Point lists, interface language packs and model / packaging marking can be supplied to project agreement; anything not listed in the order confirmation is supplied as standard. Warranty terms and service channels are per contract. CE, FCC and RoHS marks are applied to the housing and are not certificate numbers – ask the supplier for certificate documents when they are required.
Point tables, interface language packs, model marking and packaging marking can be adapted for OEM projects. Send your point list and protocol requirements and we will confirm feasibility and lead time.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2024
Total Annual:
$1M- $5M
Employee Number:
10~30
Ecer Certification:
Verified Supplier
Shenzhen Qingchen Telecommunications Co., Ltd. is a manufacturer of building automation and industrial control equipment based in Bao'an District, Shenzhen. We bring together research and development, production, sales and service, supplying environmental sensors, field controllers, protocol gateway... Shenzhen Qingchen Telecommunications Co., Ltd. is a manufacturer of building automation and industrial control equipment based in Bao'an District, Shenzhen. We bring together research and development, production, sales and service, supplying environmental sensors, field controllers, protocol gateway...
Get in touch with us
Leave a Message, we will call you back quickly!