China MatyLink QSP-800B Protocol Gateway | 4 x Modbus RTU to BACnet, 2048 Points
China MatyLink QSP-800B Protocol Gateway | 4 x Modbus RTU to BACnet, 2048 Points

  1. China MatyLink QSP-800B Protocol Gateway | 4 x Modbus RTU to BACnet, 2048 Points
  2. China MatyLink QSP-800B Protocol Gateway | 4 x Modbus RTU to BACnet, 2048 Points
  3. China MatyLink QSP-800B Protocol Gateway | 4 x Modbus RTU to BACnet, 2048 Points

MatyLink QSP-800B Protocol Gateway | 4 x Modbus RTU to BACnet, 2048 Points

  1. MOQ: 1 Piece
  2. Price: US$415 - 475 / Piece
  3. Get Latest Price
Payment Terms T/T
Delivery Time 7-15 work days
Model Number QSP-800B
Brand Name MatyLink
Place of Origin Shenzhen, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Delivery Time 7-15 work days
Model Number QSP-800B Brand Name MatyLink
Place of Origin Shenzhen, China

MatyLink QSP-800B is a protocol conversion gateway that brings Modbus RTU field equipment into a BACnet building automation system. On the Modbus side the gateway works as a master, polling downstream slave devices on four RS485 ports (up to 32 slaves per port). On the BACnet side it works as a server, presenting up to 2048 points to the head-end as standard BACnet objects. No gateway software is needed: channels, devices and points are configured from a built-in web page in any browser.

How it works

  • Modbus RTU master, BACnet server – the gateway polls Modbus slaves and exposes the values as BACnet AI, AO, AV, BI, BO and BV objects.
  • BACnet/IP or BACnet MS/TP – one BACnet data link is selected in software and takes effect after restart; BACnet/IP uses the RJ45 Ethernet port, BACnet MS/TP uses a dedicated RS485 port that is separate from the Modbus ports.
  • Scaled engineering values – linear scaling, bit extraction and binary state text convert raw registers into engineering units or status text.
  • Read/write by object type – AI and BI objects are read-only; AO, AV, BO and BV Present_Value can be written from BACnet and are written back to the Modbus slave.

Key features

  • Four Modbus RTU RS485 master ports with 2400–115200 bit/s baud rate, 7/8 data bits, 1/2 stop bits and N/O/E parity
  • Up to 2048 BACnet points; BACnet device instance, UDP port 47808 and MS/TP MAC address are configurable
  • Object types: Device, AI, AO, AV, BI, BO, BV; BACnet services Who-Is, Who-Has, ReadProperty, ReadPropertyMultiple, WriteProperty, ReinitializeDevice and DeviceCommunicationControl
  • Built-in web configuration – no dedicated software to install; interface text can be switched with language packs
  • Dual-slot configuration storage: an interrupted config write does not destroy the running configuration
  • Web firmware upgrade (OTA), configuration export/import (.m2b / .json) and a built-in real-time clock
  • Persistent log (/log, 2048 entries retained after power loss) and run-time log (/ramlog, last 64 entries) for after-sales diagnosis
  • Metal housing, pluggable green terminals, 35 mm DIN-rail mounting, RS485 surge protection

Technical specifications

Model QSP-800B
Function Modbus RTU to BACnet protocol conversion gateway
Modbus RS485 ports 4 x RS485, master
Max. slaves per port 32
Max. BACnet points 2048
Modbus baud rate 2400–115200 bit/s (web presets: 9600 / 19200 / 38400 / 57600 / 115200)
Modbus serial format Data bits 7/8, stop bits 1/2, parity N/O/E
Modbus slave address 1–247, unique within a port
Modbus function codes 01, 02, 03, 04, 05, 06, 15, 16
Point data types Bool, Word, Short, DWord, Long, Float, Double; byte order configurable for word/dword/float
Polling parameters Response timeout 200 ms default; polling period 1000 ms default (configurable per channel)
BACnet data link BACnet/IP or BACnet MS/TP (one at a time, effective after restart)
BACnet/IP UDP 47808 (configurable); configurable device instance
BACnet MS/TP Dedicated RS485 port; MAC 0–127; 9600–115200 bit/s, default 76800 bit/s
BACnet objects Device, AI, AO, AV, BI, BO, BV (AO/AV/BO/BV Present_Value writable)
BACnet APDU 480 B, no segmentation; 20–25 objects per ReadPropertyMultiple recommended
Ethernet 1 x RJ45, 10/100 Mbps (BACnet/IP and web configuration)
Supply / power AC/DC 9–24 V; less than 3 W
Default network 192.168.0.88/24, gateway 192.168.0.1, HTTP port 80 (restored by factory reset)
Enclosure Metal housing; 97.96 mm x 125.98 mm; 30 mm mounting ears each side (approx. 157.96 mm overall width)
Mounting DIN rail
Terminals Pluggable green terminals (mating plugs supplied)
Operating temperature -20 °C to +70 °C
Operating humidity 0% to 95% RH, non-condensing
RS485 cable length Up to 1000 m
Ethernet cable length Cat 5 or better, up to 150 m
Sample cycle Approx. 1.5 s (bench reference: 20 points, one channel at 9600 8N1, 1000 ms polling)
Marking CE, FCC, RoHS marked on the housing (certificate documents on request)

MatyLink model range

Model Modbus RS485 ports Max. slaves per port Max. BACnet points Supply / power
QSP-400B 4 x RS485 32 slaves 1024 AC/DC 9–24 V, < 3 W
QSP-800B (this model) 4 x RS485 32 slaves 2048 AC/DC 9–24 V, < 3 W
DSP-200B 2 x RS485 32 slaves 512 AC/DC 9–24 V, < 3 W
DSP-100B 2 x RS485 8 slaves 256 AC/DC 9–24 V, < 3 W

The three-digit number in the model name is a series code, not a point count: QSP models have four RS485 ports, DSP models have two. All four models share the same BACnet object types, service set and web configuration method; they differ only in Modbus port count, slaves per port and maximum point capacity.

Integration boundaries

  • Modbus side – RS485 Modbus RTU master only. Modbus TCP and Modbus ASCII are not supported; downstream devices must answer as standard Modbus RTU slaves in the 1–247 address range.
  • BACnet side – BACnet/IP and BACnet MS/TP cannot be active at the same time. The two RS485 worlds stay separate: the MS/TP port is dedicated to BACnet.
  • Object scope – one BACnet object per configured point; no multi-state, accumulator or trend objects are provided by the gateway.
  • Client compatibility – with a 480 B APDU and no segmentation, clients should read the object list with array-index paging and keep ReadPropertyMultiple requests to roughly 20–25 objects.
  • Legacy tooling – the gateway also accepts the legacy M2BACnet configuration tool (UDP discovery, TCP 0x7E frames); browser configuration alone is sufficient.

Applications

Typical downstream equipment includes electricity meters, flow meters, lifts and escalators, variable frequency drives, central-plant chillers, heating boilers and water supply / drainage equipment. The gateway only collects Modbus data and converts it to BACnet objects; it does not drive fans, pumps or valves directly – start/stop and modulation stay with the existing controllers or head-end.

Commissioning

  • Factory network settings: 192.168.0.88, mask 255.255.255.0, gateway 192.168.0.1; open http://192.168.0.88 in a browser to configure.
  • Configuration order: add channels (port, baud rate, parity, timeout, polling period), then devices (name, Modbus slave address, byte order), then points (name, BACnet object type and instance, register type, address, data type, scaling).
  • Short-press RST to restart; hold RST for about 5 seconds to restore factory defaults (this clears the point table – export the configuration first).
  • Green LED blinking indicates normal operation; a blinking red LED indicates factory / recovery mode, an authorisation fault or a run-time fault – check /log and contact the supplier.

Ordering and compliance

Standard supply: gateway unit, mating pluggable terminals and accompanying documents. BACnet/IP or BACnet MS/TP is selected by software configuration and does not change the hardware model. Point lists, interface language packs and model / packaging marking can be supplied to project agreement; anything not listed in the order confirmation is supplied as standard. Warranty terms and service channels are per contract. CE, FCC and RoHS marks are applied to the housing and are not certificate numbers – ask the supplier for certificate documents when they are required.

OEM / ODM

Point tables, interface language packs, model marking and packaging marking can be adapted for OEM projects. Send your point list and protocol requirements and we will confirm feasibility and lead time.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    2024

  • Total Annual:

    $1M- $5M

  • Employee Number:

    10~30

  • Ecer Certification:

    Verified Supplier

Shenzhen Qingchen Telecommunications Co., Ltd. is a manufacturer of building automation and industrial control equipment based in Bao'an District, Shenzhen. We bring together research and development, production, sales and service, supplying environmental sensors, field controllers, protocol gateway... Shenzhen Qingchen Telecommunications Co., Ltd. is a manufacturer of building automation and industrial control equipment based in Bao'an District, Shenzhen. We bring together research and development, production, sales and service, supplying environmental sensors, field controllers, protocol gateway...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Qingchen Telecommunications Co., Ltd.
  • 313, Kunhong Building, 38 Xinhe Avenue, Xinqiao Community, Xinqiao Subdistrict, Bao'an District, Shenzhen, China 518104
  • https://www.matinal-tech.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement