China factories

China factory - Echo Extraction Inc

Echo Extraction Inc

  • China,Suzhou
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China High Capacity HPLC Autosampler Low Carryover For Food Safety Testing
China High Capacity HPLC Autosampler Low Carryover For Food Safety Testing

  1. China High Capacity HPLC Autosampler Low Carryover For Food Safety Testing

High Capacity HPLC Autosampler Low Carryover For Food Safety Testing

  1. MOQ: 1 Set
  2. Price: Contact Us for Pricing
  3. Get Latest Price
Payment Terms T/T
Supply Ability 50+ Sets per Month
Delivery Time 15–45 Days
Packaging Details Export-Standard Plywood Case
Injection Volume Range 0.01-100 µL, 0.01 µL steps
Injection Precision <0.3% RSD at 5 µL, <1.0% RSD at 0.5 µL
Carryover <0.003% with suitable wash protocol
Sample Capacity 216 × 2 mL vials; 2 × 96 or 384-well plates
Sample Temperature 4-40°C, Peltier controlled, ±0.5°C
Needle Material Passivated 316L SS, electropolished Ra<0.2
Brand Name Echo
Model Number Echo
Certification CE/ISO
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 50+ Sets per Month
Delivery Time 15–45 Days Packaging Details Export-Standard Plywood Case
Injection Volume Range 0.01-100 µL, 0.01 µL steps Injection Precision <0.3% RSD at 5 µL, <1.0% RSD at 0.5 µL
Carryover <0.003% with suitable wash protocol Sample Capacity 216 × 2 mL vials; 2 × 96 or 384-well plates
Sample Temperature 4-40°C, Peltier controlled, ±0.5°C Needle Material Passivated 316L SS, electropolished Ra<0.2
Brand Name Echo Model Number Echo
Certification CE/ISO Place of Origin China
High Light High Capacity HPLC AutosamplerHigh Capacity hplc samplerHPLC Autosampler For Food Safety Testing
HPLC/UHPLC Autosampler with Low Carryover for Food Safety Pesticide Residue Testing
Product Overview

Maximize sample throughput and data integrity with our flow-through autosampler, designed for high-sensitivity pesticide residue, veterinary, and mycotoxin analysis. It delivers injection precision better than 0.3% RSD even at 0.1 µL volumes, with a verified carryover specification of less than 0.003%. The thermostat-controlled tray protects thermally labile samples and maintains chain of custody. An advanced needle wash routine and programmable injection sequences, including air gap sandwiching and feed injection, make it the first choice for food safety labs operating under ISO 17025 and SANTE guidelines.

Cause

Carryover is the number-one enemy of trace-level analysis. In pesticide residue labs, a single high-concentration control sample can leave fuberidazole or chlorpyrifos on the needle seat, producing a false positive in the next blank injection. Sample degradation on the bench causes inaccurate results. Manual sample prep mistakes—missed vials, transposition errors, mislabeling—cost hours of re-analysis. Additionally, validation protocols like SANTE/11312/2021 demand proof of carryover ≤0.1% for each analyte, and a poorly designed autosampler cannot meet this goal.

Solution

We engineered the autosampler with a true flow-through needle that is continuously flushed by mobile phase between runs. The needle and seat are fabricated from passivated stainless steel with an electropolished finish (Ra<0.2 µm) to eliminate adsorption sites. Four programmable wash solvents are available; the system can rinse the external needle surface with strong organic and then water, sequentially. The sample tray holds 216 standard 2-mL vials, or 384-well plates via an adaptor, and can be set to 4°C to 40°C. Pre-injection air gaps prevent sample dispersion. Full barcode reading and LIMS integration eliminate manual data entry, so your run log is auditable from vial scan to final report.

Specifications
Parameter Specification
Injection Volume Range 0.01–100 µL, 0.01 µL steps
Injection Precision <0.3% RSD at 5 µL, <1.0% RSD at 0.5 µL
Carryover <0.003% with suitable wash protocol
Sample Capacity 216 × 2 mL vials; 2 × 96 or 384-well plates
Sample Temperature 4–40°C, Peltier controlled, ±0.5°C
Needle Material Passivated 316L SS, electropolished Ra<0.2
Wash Stations 4 solvent, integrated peristaltic pumps
Barcode Reader Integrated 1D/2D, code-128, QR
Communication Ethernet, trigger/timed events
Compliance 21 CFR Part 11, ISO 17025, SANTE/11312/2021
Application
  • Multi-residue pesticide analysis in fruits and vegetables (QuEChERS extracts)

  • Veterinary residues in meat/seafood

  • Mycotoxins in cereals, nuts, and spices

  • Trace nitrosamines in substances

  • Drinking water organic contaminant monitoring

  • Clinical TDM (therapeutic monitoring)

How It Works

The robotic arm picks a vial, reads the barcode, then draws the sample into the sample loop or needle seat. A high-precision syringe drive meters the volume. Before injection, a small air gap seals the sample plug. The needle then docks into the high-pressure injection port; the valve switches to allow mobile phase to sweep the plug into the column. After injection, the needle immediately undergoes an internal flush while the external surface is washed in a separate station, all before the next vial is picked, completely decoupling sample from sample.

How To Choose

Calculate your daily sample load: a 216-vial capacity supports roughly 200 injections/day on a 10-min method. If you run overnight batches, a second tray can be pre-loaded on a swap cart for 5-min changeover. Choose the wash station solvents based on your analytes: use DMSO or DMF for tough-to-remove compounds. For wines or high-sugar matrices, include a water wash step to prevent sucrose crystallization. Request a demo with your worst-case analyte to verify carry-over; we will provide a test protocol and data before purchase.

FAQ

Q1: Can I use 96-well plates directly?
A: Yes, with an optional plate handler. The system holds two deep-well plates or four microtiter plates, maintaining temperature control throughout.

Q2: How do you prevent needle clogging from particulate samples?
A: We recommend filtering all samples to 0.2 µm. The system also includes a pressure watchdog that aborts the injection if back-pressure exceeds a user-defined maximum, preventing column damage.

Q3: How long does it take to wash the needle?
A: A standard double-wash program takes 25 seconds. Needle wash occurs during the chromatographic run, so it adds zero extra cycle time.

Q4: Is dead volume minimized for fast UHPLC?
A: Yes, the entire flow path from needle tip to column inlet has a dispersion volume under 5 µL with a 0.12 mm i.d. tubing kit, preserving UHPLC peak shape.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Distributor/Wholesaler,Agent,Exporter

  • Year Established:

    Establishe

  • Total Annual:

    2,000,000-USD 5,000,000

  • Employee Number:

    15~30

  • Ecer Certification:

    Verified Supplier

Complete Plant Extraction Solutions Provider We help you build efficient, scalable, and cost-effective plant extraction operations — from concept to full production. As a professional solution provider, we specialize in delivering complete plant extraction systems and flexible supply options... Complete Plant Extraction Solutions Provider We help you build efficient, scalable, and cost-effective plant extraction operations — from concept to full production. As a professional solution provider, we specialize in delivering complete plant extraction systems and flexible supply options...

+ Read More

Get in touch with us

  • Reach Us
  • Echo Extraction Inc
  • NO.209 ZHUYUAN ROAD, HUQIU, CHINA SUZHOU INNOVATION PARK 215011.
  • https://www.plantextractmachine.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement