China factories

Chat Now Send Email
China factory - Anhui Tongdu International Trade Co., Ltd.

Anhui Tongdu International Trade Co., Ltd.

  • China,Hefei ,Anhui
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China 0.6/1kV ZC-YJV 5x16mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for
China 0.6/1kV ZC-YJV 5x16mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for

  1. China 0.6/1kV ZC-YJV 5x16mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for
  2. China 0.6/1kV ZC-YJV 5x16mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for
  3. China 0.6/1kV ZC-YJV 5x16mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for
  4. China 0.6/1kV ZC-YJV 5x16mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for
  5. China 0.6/1kV ZC-YJV 5x16mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for
  6. China 0.6/1kV ZC-YJV 5x16mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for

0.6/1kV ZC-YJV 5x16mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for

  1. MOQ: 100 meters
  2. Price:
  3. Get Latest Price
Insulation (×5)​ XLPE compound, extruded (colours: brown/black/grey/blue + green-yellow for 3L+N+PE)
Binder​ Flame-retardant glass-fibre / FR tape​ (ZC grade) over laid-up cores
Number of cores 5
Conductor construction Class 2, 7×∅1.70 mm
Supply Ability 100000 meters per month
Sheath thickness 1.8 mm​ (multi-core rule, ≥1.8 mm)
Overall cable diameter 21.3 – 22.4 mm
Insulation thickness 0.7 mm​ (GB/T 12706.1, 10/16 mm² class)
Conductor (×5) Bare annealed copper, Class 2 stranded circular, 7×∅1.70 mm​
Filler Flame-retardant non-hygroscopic PP/PE filler​ (ZC grade) to form round assembly
Payment Terms L/C,T/T
Outer sheath Flame-retardant PVC​ compound (ZC grade)
Approx. weight 965 – 1053 kg/km
Packaging Details General Packaging or As Requirements
Conductor nominal area 16 mm²
Conductor diameter (approx.) 5.0 – 5.1 mm
Model Number ZC-YJV 5x16mm²‌
Certification CE/ISO/CCC
Brand Name TD
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Insulation (×5)​ XLPE compound, extruded (colours: brown/black/grey/blue + green-yellow for 3L+N+PE) Binder​ Flame-retardant glass-fibre / FR tape​ (ZC grade) over laid-up cores
Number of cores 5 Conductor construction Class 2, 7×∅1.70 mm
Supply Ability 100000 meters per month Sheath thickness 1.8 mm​ (multi-core rule, ≥1.8 mm)
Overall cable diameter 21.3 – 22.4 mm Insulation thickness 0.7 mm​ (GB/T 12706.1, 10/16 mm² class)
Conductor (×5) Bare annealed copper, Class 2 stranded circular, 7×∅1.70 mm​ Filler Flame-retardant non-hygroscopic PP/PE filler​ (ZC grade) to form round assembly
Payment Terms L/C,T/T Outer sheath Flame-retardant PVC​ compound (ZC grade)
Approx. weight 965 – 1053 kg/km Packaging Details General Packaging or As Requirements
Conductor nominal area 16 mm² Conductor diameter (approx.) 5.0 – 5.1 mm
Model Number ZC-YJV 5x16mm²‌ Certification CE/ISO/CCC
Brand Name TD Place of Origin China
High Light xlpe 5 core cable ,xlpe copper conductor cable ,black 5 core cable

0.6/1kV ZC-YJV 5x16mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Residential Main Distribution

Technical Datasheet — ZC-YJV 0.6/1 kV 5×16 mm²

1. Cable Designation & Meaning

Code

Meaning

ZC​

Flame retardant, Class C​ (bundled combustion test per GB/T 18380.3 / GB/T 19666)

YJ​

XLPE (cross-linked polyethylene) insulation

V​

PVC (polyvinyl chloride) outer sheath (flame-retardant ZC grade)

0.6/1 kV​

Rated voltage U₀/U = 600/1000 V; max. system voltage Uₘ = 1.2 kV

5×16 mm²​

Five cores, nominal copper conductor area 16 mm² per core

Construction​

Unarmoured, non-screened, round multi-core

2. Applicable Standards

  • GB/T 12706.1-2020​ (equiv. IEC 60502-1) — Extruded insulation power cables ≤ 1 kV
  • GB/T 3956 / IEC 60228​ — Conductors (Class 2)
  • GB/T 19666-2019​ — Flame retardant & fire resistant cables (ZC = Class C)
  • GB/T 18380.3​ — Bunched flame propagation test, Class C (char ≤ 2.5 m above burner)
  • GB/T 16895.15 / IEC 60364-5-52​ — Current-carrying capacity reference for installation

3. Product Components / Construction (inside → outside)

  1. Conductor (×5)​ — Bare annealed copper, Class 2 stranded circular, 7×∅1.70 mm​ (typical); conductor diameter ≈ 5.0–5.1 mm
  2. Conductor screen​ — Not required for 0.6/1 kV; omitted
  3. Insulation (×5)​ — XLPE compound, extruded (colours: brown/black/grey/blue + green-yellow for 3L+N+PE)
  4. Insulation thickness (nominal)​ — 0.7 mm​ (GB/T 12706.1, 10/16 mm² class)
  5. Filler​ — Flame-retardant non-hygroscopic PP/PE filler​ (ZC grade) to form round assembly
  6. Binder​ — Flame-retardant glass-fibre / FR tape​ (ZC grade) over laid-up cores
  7. Outer sheath​ — Flame-retardant PVC​ compound (ZC grade)
  8. Sheath thickness (nominal)​ — 1.8 mm​ (multi-core rule, ≥1.8 mm)
  9. Sheath colour​ — Black (standard); other colours available
  10. Armour​ — None
  11. Metallic screen​ — None

4. Dimensional Data


Item

Typical value

Remarks

Conductor nominal area (per core)

16 mm²

—

Number of cores

5

3L + N + PE typical

Conductor construction

Class 2, 7×∅1.70 mm​

min. 7 wires per GB/T 3956

Conductor diameter (approx.)

5.0 – 5.1 mm​


Insulation nominal thickness

0.7 mm​


Diameter over one insulated core (approx.)

6.4 mm

5.0 + 2×0.7

Sheath nominal thickness

1.8 mm​


Overall cable diameter

21.3 – 22.4 mm​

21.3, 21.7 (Made-in-China/YJV std.), 21.8 (gbt12706), 22.4 , 22.6 ; use 22.0 mm for design​

Approx. weight

965 – 1053 kg/km​

965 (Made-in-China), 1000 (gbt12706 YJV), 1004  1011 , 1053 ; use ≈ 1010 kg/km​

Cable shape

Round

—



5. Insulation Data

  • Material:​ XLPE (cross-linked polyethylene)
  • Nominal thickness:​ 0.7 mm (GB/T 12706.1, 16 mm² at 0.6/1 kV)
  • Long-term service temperature:​ 90 °C
  • Short-circuit temperature (≤5 s):​ 250 °C​
  • Emergency overload:​ 105–130 °C (limited duration, general XLPE practice)
  • Routine test:​ 3.5 kV AC / 5 min; type test 4.0 kV
  • Volume resistivity @90 °C:​ ≥ 10¹² Ω·cm (typical XLPE)
  • Insulation resistance:​ ≥ 100 MΩ·km @20 °C (500 V megger); constant R₀·L ≈ 3.67 MΩ·km @90 °C

6. Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

Uₘ = 1.2 kV

Test voltage AC (5 min)

3.5 kV​

Routine test

Type-test voltage

4.0 kV

IEC 60502 practice

DC resistance @20 °C (Class 2 Cu, per core)​

≤ 1.15 Ω/km​

GB/T 3956 / IEC 60228 max

AC resistance @90 °C (est.)

≈ 1.50 Ω/km

copper temp. coefficient

Recommended current rating — in air (30 °C, single circuit, 5-core)

≈ 84–86 A​

84, 86 , 95 ; design ≈ 85 A​

In air — bundled / tray (per )

107 A

higher, not conservative

Direct buried / in soil (20 °C, soil thermal res. 1.0 K·m/W, depth 0.7 m)

≈ 94–100 A​

94 , 100, 110 ; design ≈ 95 A​

Short-circuit current capacity (1 s adiabatic, Cu, 250 °C, per core)

≈ 1.84 kA

reference

Frequency

50/60 Hz AC (DC usable)

—



7. Temperature Characteristics

  • Max. conductor operating temp. (continuous):​ 90 °C​
  • Max. short-circuit temp. (≤5 s):​ 250 °C​
  • Emergency overload temp.:​ 105 °C (limited duration)
  • Min. ambient temp. during installation:​ 0 °C​ (pre-heat below 0 °C)
  • Service ambient temperature range:​ −20 °C to +90 °C (sheath/environment)
  • Flame retardant class:​ Category C​ per GB/T 19666 (bundled, self-extinguishing, char ≤ 2.5 m)

8. Mechanical & Installation Parameters

  • Minimum bending radius (unarmoured multi-core):​ ≥ 15 × overall diameter​ → ≈ 330 mm at Ø22 mm
  • Maximum pulling tension (copper conductor only):​ 50 N/mm² × 16 mm² × 5 = 4000 N total​ (distributed to all 5 cores)
  • PVC sheath pulling limit:​ significantly lower — avoid direct sheath grip; use conductor pulling sock
  • Direct burial:​ Allowed in non-aggressive soil; sand bed + warning tape, depth ≥ 0.7 m, conduit under roads
  • Conduit fill:​ Conduit ID ≥ 1.5 × cable OD → ≥ 33 mm (use 40 mm conduit or larger)
  • Cable tray / duct:​ 5-core is stiff; observe 15D bend radius to avoid core deformation
  • Elevation difference:​ No limitation for XLPE insulated cable

9. Material Specification Summary

  • Conductor:​ Cu ≥ 99.9 % annealed, Class 2, 7×1.70 mm, IEC 60228 / GB/T 3956
  • Insulation:​ XLPE, 0.7 mm nom., rated 90 °C (coloured per core function)
  • Filler:​ Flame-retardant PP/PE (ZC grade)
  • Binder:​ Flame-retardant glass fibre / FR tape
  • Outer sheath:​ Flame-retardant PVC (ZC), 1.8 mm nom.
  • No armour, no metallic screen




10. Scope of Application / Usage Range

ZC-YJV 0.6/1 kV 5×16 mm²​ is intended for fixed installation​ in low-voltage power distribution & transmission systems up to 1.2 kV where flame-retardant Class C​ is required. As a five-core​ cable (3L+N+PE), it is the standard choice for three-phase LV supplies with separate neutral and protective earth.

Typical applicable locations:

  • Three-phase distribution feeders​ (L1/L2/L3 + N + PE) for equipment, motors, distribution boards, and final sub-circuits in TN-S / TN-C-S​ systems
  • Indoor/outdoor distribution rooms, floor distribution cabinets, and risers in high-rise buildings, hotels, shopping malls, hospitals, schools, stations and metros​ (where ZC flame-retardant grade is mandated by fire code)
  • Cable trays, cable ducts, cable trenches & shafts in commercial / residential / public buildings
  • Industrial plants, warehouses, small-to-medium machinery and HVAC feeders, elevator power supplies
  • Direct buried routes in non-aggressive soil with low mechanical impact
  • Renewable / PV inverter AC output and EV charger three-phase branch circuits (polarity/earthing design required)



Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Year Established:

    2009

  • Total Annual:

    50000000-100000000

  • Employee Number:

    260~300

  • Ecer Certification:

    Verified Supplier

Company Profile — Anhui Tongdu Cable Co., Ltd. Company Overview Anhui Tongdu Cable Co., Ltd. (hereinafter "Tongdu Cable") is a professional wire and cable manufacturer headquartered in Zongyang Economic Development Zone, Anhui Province, China. Founded in 2009, the company has grown into one of... Company Profile — Anhui Tongdu Cable Co., Ltd. Company Overview Anhui Tongdu Cable Co., Ltd. (hereinafter "Tongdu Cable") is a professional wire and cable manufacturer headquartered in Zongyang Economic Development Zone, Anhui Province, China. Founded in 2009, the company has grown into one of...

+ Read More

Get in touch with us

  • Reach Us
  • Anhui Tongdu International Trade Co., Ltd.
  • Room 2003,B Building,Jiaqiao International Plaza,Baohe District,Hefei City,Anhui Province
  • https://www.power-cabling.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement