| Packaging Details | Standard Export Packing |
| Delivery Time | To Be Negotiated |
| Payment Terms | T/T,L/C,Western Union |
| Supply Ability | To Be Negotiated |
| Name | Environmental Protection Equipment |
| Rotation Speed | 300-1800 RPM |
| Heat Transfer Increase | 20% |
| Minimum Water Flow | 60% of design value |
| Hydraulic Resistance | 0.02-0.03 MPa |
| Tube Inner Diameter | 18.8 mm |
| Flow Velocity | 2 m/s |
| Place of Origin | Chongqing-China |
| Brand Name | Huanxiang |
| Certification | CE,ISO,KEMA,GOST |
| Model Number | Customized |
View Detail Information
Explore similar products
Fire resistant oil treatment device and fuel purification device for increasing
Zero Emission Technology for Clean Energy and Eco-Friendly Industrial Solutions
Advanced Oxidation Catalyst M with Large Specific Surface Area High Catalytic
Fully Enclosed Domestic Waste Incinerator with High Incineration Efficiency and
Product Specification
| Packaging Details | Standard Export Packing | Delivery Time | To Be Negotiated |
| Payment Terms | T/T,L/C,Western Union | Supply Ability | To Be Negotiated |
| Name | Environmental Protection Equipment | Rotation Speed | 300-1800 RPM |
| Heat Transfer Increase | 20% | Minimum Water Flow | 60% of design value |
| Hydraulic Resistance | 0.02-0.03 MPa | Tube Inner Diameter | 18.8 mm |
| Flow Velocity | 2 m/s | Place of Origin | Chongqing-China |
| Brand Name | Huanxiang | Certification | CE,ISO,KEMA,GOST |
| Model Number | Customized | ||
| High Light | 300 RPM Environmental Protection Equipment ,1800 RPM Environmental Protection Equipment ,RCCS Condenser Online Tube Cleaning System | ||
RCCS Real-Time Online Condenser Cleaning System with Enhanced Heat Transfer and Ceramic Bearing Technology
What is RCCS?
RCCS means the Real-Time Online Condenser Cleaning & Enhanced Heat Transfer System.
RCCS consists of spiral twisted tape, ceramic bearings and special steel supports. RCCS is installed in the condenser heat exchange tube, without additional power, driven by the flow velocity of circulating water itself. It rotates rapidly at the speed of 300-1800 RPM to achieve enhanced heat transfer and online fouling cleaning, and it can effectively increase the condenser heat transfer coefficient K value by more than 20%. There are more than 2500 power units have using this technology and have been installed RCCS®, it is one of CIMS®'s core subsystems that monitor RCCS® RPM and condenser cleanliness in real time.
![]()
RCCS Condenser Heat Transfer Enhancement System
Proprietary ceramic bearing technology and fluorinated surface treatment technology.
Online monitoring of rotational speed and remote IoT module integration.
When RCCS is used independently for cold-end energy-saving retrofit, certain requirements must be met for circulating water quality and flow rate. Water quality must comply with national industrial circulating water standards, and the circulating water volume must exceed 60% of the minimum design value.
Over 2,500 units installed, including more than 300 cases in the steel industry.
![]()
![]()
RCCS Heat Transfer Enhancement System
![]()
RCCS Heat Transfer Enhancement Principle
![]()
RCCS Heat Transfer Enhancement
![]()
Comparison of K values for tube installed with RCCS and without RCCS In the comparison figure, the working medium of pipe side is water and the shell side is steam
RCCS Online Fouling Cleaning Principle
![]()
RCCS Online Fouling Cleaning
![]()
Heat Exchanger Tubes' status after 3 months' trial operation (After RCCS installation - Chongqing Tongxing Waste Incineration Power Plant)
![]()
The picture is the heat exchanger tubes after 18 months' operation after RCCS installation, they are just like the new tubes.(Chongqing Tongxing Waste Incineration Power Plant)
RCCS Principle of Energy-saving & Consumption Deducing
![]()
RCCS Energy-saving & Consumption Reducing
![]()
RCCS Low Hydraulic Resistance
![]()
![]()
The chart above shows the test results. The test data show that for a 12m inner polished stainless-steel pipe with an inner diameter of 18.8mm and a flow velocity of 2m/s (Re=38000), the head loss will increase by approx. 0.02-0.03Mpa with RCCS installed.
RCCS Prolongs Equipment’s Service Life
![]()
Long-term fouling in heat exchange tube easy to cause corrosion under the scale, equipment perforation, tube wear and other problems, using RCCS can not wear the pipe wall, and can not take any effects for the pipe wall, so it can prolong equipment's service life.
Performance Comparison Between Rubber Ball Cleaning with RCCS
![]()
Reduce Condenser's Terminal Temperature Difference
![]()
Using Effects Comparison after RCCS Installation
![]()
Company Details
Business Type:
Manufacturer
Year Established:
2017
Total Annual:
20000000usd-25000000usd
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Founded in 2017, Chongqing Huanxiang Industrial Co., Ltd. is located in Cuntan Bonded Port Area of Chongqing, an advantageous region in the upper reaches of the Yangtze River with convenient transportation. Since its establishment, the company has adhered to a development model of integrated R&... Founded in 2017, Chongqing Huanxiang Industrial Co., Ltd. is located in Cuntan Bonded Port Area of Chongqing, an advantageous region in the upper reaches of the Yangtze River with convenient transportation. Since its establishment, the company has adhered to a development model of integrated R&...
Get in touch with us
Leave a Message, we will call you back quickly!