Payment Terms | T/T, L/C, Western Union |
Supply Ability | 100 sets per year |
Delivery Time | 15-35 working days |
Packaging Details | Plywood Cases |
Nominal Voltage | 200kV or at Customized |
Rated Energy | 10kJ or at Customized |
Impulse Capacitance | 0.5UF or at Customized |
Each Stage | 100kv 0.25UF or at Customized |
Standard | IEC |
Display | LCD |
Brand Name | Sansion |
Model Number | SXCF |
Certification | ISO, SGS, CE, ilac-MRA, CNAS |
Place of Origin | Wuhan, China |
View Detail Information
Explore similar products
Industry Grade AC Impulse Voltage Generator Dynamic Load SXCF SGS Certificated
Customized Capacitance impulse current generator Power Testing System Long Life
High Voltage AC Impulse Current Generator Hipot Mechanical Load Computer
Computer Control High Current Pulse Generator 400 KV / 30 KJ For Impact Testing
Product Specification
Payment Terms | T/T, L/C, Western Union | Supply Ability | 100 sets per year |
Delivery Time | 15-35 working days | Packaging Details | Plywood Cases |
Nominal Voltage | 200kV or at Customized | Rated Energy | 10kJ or at Customized |
Impulse Capacitance | 0.5UF or at Customized | Each Stage | 100kv 0.25UF or at Customized |
Standard | IEC | Display | LCD |
Brand Name | Sansion | Model Number | SXCF |
Certification | ISO, SGS, CE, ilac-MRA, CNAS | Place of Origin | Wuhan, China |
High Light | high voltage impulse generator ,impulse voltage generator |
200kV / 10kJ High Voltage Impulse Voltage Test System For Lighting Test
System instruction Main Parameters for System
1. Nominal voltage: ±200kV
2. Rated stage voltage: ±100kV
3. Rated energy: 10kJ
4. Impulse capacitance: 0.5µF
5. Number of stages: 2
Rated stage capacitance: 1µF(each impulse capacitor 1µF at 100kV, total 2pcs)
Impulse voltage waveform: generated when load capacitance is 300-3000pF.
T1=1.2µs±30%, T2=50µs±20%, standard lightning impulse voltage full waveform of peak voltage deviation≤3%;
Standard operation waveform 250±20%/2500±60%. These 2 Impulse voltage waveform parameters and error are accorded with national requirements of IEC standard.
1. Voltage utilization factor: Standard lightning impulse voltage waveform ≥90% when load capacitance is below 1000pF, standard operation impulse voltage waveform≥80% when load capacitance is below 2000pF.
2. Standard operation impulse voltage waveform ≥70%.
3. Locking range: level voltage is within the range of 20%-100% rated voltage, positive and negative locking range no less than 25%.
4. Out-of-control rate of synchronous discharge: <5%
5. Min. output voltage: ≥±20% of rated voltage.
6. Instability of discharge voltage: <±1.0%
7. Continuous time: Above 2/3 of rated voltage, continuous working when charge and discharge once every 120s. Below 2/3 of rated voltage, continuous working when charge and discharge once every 60s.
More details please contact Sansion Power by email for further information.
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2005
Total Annual:
1000000-1000000
Employee Number:
100~200
Ecer Certification:
Active Member
Sansion Power Electric was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment protection, w... Sansion Power Electric was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment protection, w...
Get in touch with us
Leave a Message, we will call you back quickly!