Payment Terms | T/T, L/C, Western Union |
Supply Ability | 100 Sets Per Year |
Delivery Time | 15 Work Days |
Packaging Details | Plywood Case |
Display | LCD |
Power Source | 380V/220V110V at Cutomized |
Each Stage | 100kv 0.25UF or at Customized |
Control | Computer Control |
Nominal Voltage | 200kv or at Customized |
Impulse Capacitance | 0.5UF or at Customized |
Brand Name | Sansion Power |
Model Number | SXCF |
Certification | ISO, SGS, ilac-MRA, CNAS |
Place of Origin | Wuhan, China |
View Detail Information
Explore similar products
High Voltage Impulse Voltage Test System , 200 KV / 10 KJ Impulse Generator
Industry Grade AC Impulse Voltage Generator Dynamic Load SXCF SGS Certificated
High Voltage AC Impulse Current Generator Hipot Mechanical Load Computer
Computer Control High Current Pulse Generator 400 KV / 30 KJ For Impact Testing
Product Specification
Payment Terms | T/T, L/C, Western Union | Supply Ability | 100 Sets Per Year |
Delivery Time | 15 Work Days | Packaging Details | Plywood Case |
Display | LCD | Power Source | 380V/220V110V at Cutomized |
Each Stage | 100kv 0.25UF or at Customized | Control | Computer Control |
Nominal Voltage | 200kv or at Customized | Impulse Capacitance | 0.5UF or at Customized |
Brand Name | Sansion Power | Model Number | SXCF |
Certification | ISO, SGS, ilac-MRA, CNAS | Place of Origin | Wuhan, China |
High Light | impulse voltage test equipment ,high voltage impulse generator |
Automatic Impulse Voltage Test System Generator Power Testing System for Lighting Test
System instruction Main Parameters for System
Nominal voltage: ±200kV
Rated stage voltage: ±100kV
Rated energy: 10kJ
Impulse capacitance: 0.5µF
Number of stages: 2
Rated stage capacitance: 1µF(each impulse capacitor 1µF at 100kV, total 2pcs)
Impulse voltage waveform: generated when load capacitance is 300-3000pF.
T1=1.2µs±30%, T2=50µs±20%, standard lightning impulse voltage full waveform of peak voltage deviation≤3%;
Standard operation waveform 250±20%/2500±60%. These 2 Impulse voltage waveform parameters and error are accorded with national requirements of IEC standard.
Voltage utilization factor: Standard lightning impulse voltage waveform ≥90% when load capacitance is below 1000pF, standard operation impulse voltage waveform≥80% when load capacitance is below 2000pF. Standard operation impulse voltage waveform ≥70%.
Locking range: level voltage is within the range of 20%-100% rated voltage, positive and negative locking range no less than 25%.
Out-of-control rate of synchronous discharge: <5%
Min. output voltage: ≥±20% of rated voltage.
Instability of discharge voltage: <±1.0%
Continuous time: Above 2/3 of rated voltage, continuous working when charge and discharge once every 120s. Below 2/3 of rated voltage, continuous working when charge and discharge once every 60s.
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2005
Total Annual:
1000000-1000000
Employee Number:
100~200
Ecer Certification:
Active Member
Sansion Power Electric was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment protection, w... Sansion Power Electric was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment protection, w...
Get in touch with us
Leave a Message, we will call you back quickly!