Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
| Payment Terms | T/T |
| Supply Ability | 99pcs 4-6 weeks |
| Delivery Time | 5-7 work days |
| Numberofchannels | 1 or 2 channels |
| Isolation | Galvanic isolation between input and output |
| Mountingtype | DIN Rail |
| Outputcurrent | Maximum 100 mA |
| Outputvoltage | Maximum 30 V DC |
| Powerdissipation | Less than 1.5 W |
| Inputvoltagerange | 12-30 V DC |
| Dimensions | Approx. 100 x 22.5 x 110 mm |
| Responsetime | Less than 1 ms |
| Housingmaterial | Polycarbonate or Aluminum |
| Application | Use in hazardous areas to prevent ignition of explosive atmospheres |
| Operatingtemperaturerange | -40°C to +70°C |
| Protectionlevel | IP20 |
| Productname | Intrinsic Safety Barriers |
| Brand Name | PR |
| Model Number | PR 9116B |
| Certification | CO |
| Place of Origin | Denmark |
View Detail Information
Explore similar products
DIN Rail Mount HART Transparent Repeater PR 9106B 24 VDC Supply With Splitter
PR 9107B HART Transparent Driver 24 VDC Supply Fast Response Time For Pressure
Temperature / MA Converter PR 9113B With RTD TC Input Active Passive MA Output
PR 9202B Digital Pulse Isolator Interface For NAMUR Sensors Switches
Product Specification
| Payment Terms | T/T | Supply Ability | 99pcs 4-6 weeks |
| Delivery Time | 5-7 work days | Numberofchannels | 1 or 2 channels |
| Isolation | Galvanic isolation between input and output | Mountingtype | DIN Rail |
| Outputcurrent | Maximum 100 mA | Outputvoltage | Maximum 30 V DC |
| Powerdissipation | Less than 1.5 W | Inputvoltagerange | 12-30 V DC |
| Dimensions | Approx. 100 x 22.5 x 110 mm | Responsetime | Less than 1 ms |
| Housingmaterial | Polycarbonate or Aluminum | Application | Use in hazardous areas to prevent ignition of explosive atmospheres |
| Operatingtemperaturerange | -40°C to +70°C | Protectionlevel | IP20 |
| Productname | Intrinsic Safety Barriers | Brand Name | PR |
| Model Number | PR 9116B | Certification | CO |
| Place of Origin | Denmark | ||
| High Light | PR 9116B Universal Converter ,DIN Rail Intrinsic Safety Barrier ,Intrinsic Safety Barrier SIL 2 | ||
| Operating temperature | -20°C to +60°C |
| Storage temperature | -20°C to +85°C |
| Calibration temperature | 20...28°C |
| Relative humidity | < 95% RH (non-cond.) |
| Protection degree | IP20 |
| Installation in | Pollution degree 2 & meas. / overvoltage cat. II |
| Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
| Dimensions (HxWxD) w/ PR 4500 | 109 x 23.5 x 131 mm |
| Weight approx. | 185 g |
| DIN rail type | DIN EN 60715/35 mm |
| Wire size | 0.13...2.08 mm² AWG 26...14 stranded wire |
| Stripping length | 5 mm |
| Screw terminal torque | 0.5 Nm |
| Vibration | IEC 60068-2-6 |
| 2...13.2 Hz | ±1 mm |
| 13.2...100 Hz | ±0.7 g |
| Supply voltage | 19.2...31.2 VDC |
| Fuse | 1.25 A SB / 250 VAC |
| Max. required power | ≤ 2.1 W |
| Max. power dissipation | ≤ 1.7 W |
| Test/working: Input to any | 2.6 kVAC / 300 VAC reinforced isolation |
| Analog output to supply | 2.6 kVAC / 300 VAC reinforced isolation |
| Status relay to supply | 1.5 kVAC / 150 VAC reinforced isolation |
| Temperature input, programmable (0...90%, 100...10%) | 1...60 s |
| mA / V input (programmable) | 0.4...60 s |
| 9116x1x: 2-w. sup. (term. 54...52) | 28...16.5 VDC / 0...20 mA |
| 9116x2x: 2-w. sup. (term. 54...52) | 21.4...16.5 VDC / 0...20 mA |
| Programming | PR 4500 communication interfaces |
| Signal dynamics, input | 24 bit |
| Signal dynamics, output | 16 bit |
| Signal / noise ratio | Min. 60 dB (0...100 kHz) |
| Accuracy | Better than 0.1% of sel. range |
| RTD type | Pt10/20/50/100/200/250; Pt300/Pt400/500/1000; Ni50/100/120/1000 |
| Cable resistance per wire | 50 Ω (max.) |
| Sensor current | Nom. 0.2 mA |
| Effect of sensor cable resistance (3-/4-wire) | < 0.002 Ω / Ω |
| Sensor error detection | Programmable ON / OFF |
| Short circuit detection | Yes |
| Potentiometer min....max. | 10 Ω...10 kΩ |
| Thermocouple type | B, E, J, K, L, N, R, S, T, U, W3, W5, LR |
| Cold junction compensation (CJC) via ext. sensor in 5910 | 20...28°C ≤ ±1°C, -20...20°C / 28...70°C ≤ 2°C |
| CJC via int. mounted sensor | ±(2.0°C + 0.4°C * Δt) |
| Measurement range | 0...23 mA |
| Programmable measurement ranges | 0...20 and 4...20 mA |
| Input resistance | Nom. 20 Ω + PTC 50 Ω |
| Sensor error detection | Loop break 4...20 mA |
| Measurement range | 0...12 VDC |
| Programmable measurement ranges | 0/0.2...1, 0/1...5, 0/2...10 VDC |
| Input resistance | Nom. >10 MΩ |
| Signal range | 0...23 mA |
| Programmable signal ranges | 0...20/4...20/20...0/20...4 mA |
| Load (@ current output) | ≤ 600 Ω |
| Load stability | ≤ 0.01% of span / 100 Ω |
| Sensor error indication | 0 / 3.5 / 23 mA / none |
| NAMUR NE43 Upscale/Downscale | 23 mA / 3.5 mA |
| Current limit | ≤ 28 mA |
| Max. external 2-wire supply | 26 VDC |
| Effect of external 2-wire supply voltage variation | < 0.005% of span / V |
| Relay functions | Setpoint, Window, Sensor error, Power and Off |
| Max. voltage | 250 VAC / VDC |
| Max. current | 2 A |
| Max. AC power | 500 VA |
| Max. DC current, resistive load > 30 VDC | See manual for details |
| Max. voltage | 125 VAC / 110 VDC |
| Max. current | 0.5 AAC / 0.3 ADC |
| Max. AC power | 62.5 VA / 32 W |
| EMC | 2014/30/EU & UK SI 2016/1091 |
| LVD | 2014/35/EU & UK SI 2016/1101 |
| RoHS | 2011/65/EU & UK SI 2012/3032 |
| ATEX | 2014/34/EU & UK SI 2016/1107 |
| EAC | TR-CU 020/2011 |
| EAC Ex | TR-CU 012/2011 |
| EAC LVD | TR-CU 004/2011 |
| ATEX | KEMA 10ATEX0053 X |
| IECEx | KEM 10.0022X |
| UKEX | DEKRA 21UKEX0177X DEKRA 23UKEX0104X |
| FM us | FM19US0058X / FM19CA0031X |
| INMETRO | DEKRA 23.0006X |
| UL us, UL 61010-1 | E314307 |
| UL us, UL 913 | E233311 (only 9116xx-U9) |
| CCC | 2024322316005917 |
| KCs | 21_AV4BO_0176X / 21_AV4BO_0177X (only 9116Bx-KCs) |
| EAC Ex | EAEU KZ 7500361.01.01.08756 |
| DNV Marine | TAA00000JD |
| ClassNK | TA24034M |
| SIL | SIL 2 certified & fully assessed acc. to IEC 61508 |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Exporter,Trading Company,Seller
Year Established:
2018
Total Annual:
5000000-10000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
.gtr-container-def789 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #1a1a19; line-height: 1.6; padding: 16px; max-width: 100%; box-sizing: border-box; overflow-wrap: break-word; } .gtr-container-def789 p { font-size: 14px;... .gtr-container-def789 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #1a1a19; line-height: 1.6; padding: 16px; max-width: 100%; box-sizing: border-box; overflow-wrap: break-word; } .gtr-container-def789 p { font-size: 14px;...
Get in touch with us
Leave a Message, we will call you back quickly!