Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
| Payment Terms | T/T |
| Supply Ability | 99pcs 4-6 weeks |
| Delivery Time | 5-7 work days |
| Operatingtemperaturerange | -40°C to +85°C |
| Weight | Approx. 150g |
| Inputvoltagerange | 12V to 250V AC/DC |
| Isolationvoltage | 2500V RMS |
| Protectiontype | Intrinsic Safety (Ex i) |
| Numberofchannels | 1 or 2 channels |
| Mountingtype | DIN Rail Mount |
| Responsetime | Less than 1ms |
| Housingmaterial | Flame-retardant polycarbonate |
| Productname | Intrinsic Safety Barriers |
| Application | Hazardous area signal isolation and protection |
| Powerdissipation | Max 1.5W |
| Dimensions | 115mm x 22.5mm x 110mm |
| Outputcurrent | Up to 250mA |
| Brand Name | PR |
| Model Number | PR 9106B |
| Certification | CO |
| Place of Origin | Denmark |
View Detail Information
Explore similar products
PR 9107B HART Transparent Driver 24 VDC Supply Fast Response Time For Pressure
Temperature / MA Converter PR 9113B With RTD TC Input Active Passive MA Output
DIN Rail Mount Intrinsic Safety Barrier PR 9116B Universal Converter With
PR 9202B Digital Pulse Isolator Interface For NAMUR Sensors Switches
Product Specification
| Payment Terms | T/T | Supply Ability | 99pcs 4-6 weeks |
| Delivery Time | 5-7 work days | Operatingtemperaturerange | -40°C to +85°C |
| Weight | Approx. 150g | Inputvoltagerange | 12V to 250V AC/DC |
| Isolationvoltage | 2500V RMS | Protectiontype | Intrinsic Safety (Ex i) |
| Numberofchannels | 1 or 2 channels | Mountingtype | DIN Rail Mount |
| Responsetime | Less than 1ms | Housingmaterial | Flame-retardant polycarbonate |
| Productname | Intrinsic Safety Barriers | Application | Hazardous area signal isolation and protection |
| Powerdissipation | Max 1.5W | Dimensions | 115mm x 22.5mm x 110mm |
| Outputcurrent | Up to 250mA | Brand Name | PR |
| Model Number | PR 9106B | Certification | CO |
| Place of Origin | Denmark | ||
| High Light | HART Transparent Repeater 24 VDC ,Splitter function Intrinsic Safety Barrier ,PR 9106B | ||
| Operating temperature | -20°C to +60°C |
| Storage temperature | -20°C to +85°C |
| Calibration temperature | 20...28°C |
| Relative humidity | < 95% RH (non-condensing) |
| Protection degree | IP20 |
| Installation environment | Pollution degree 2 & measurement/overvoltage category II |
| Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
| Dimensions with PR 4500 | 109 x 23.5 x 131 mm |
| Weight approx. | 250 g |
| DIN rail type | DIN EN 60715/35 mm |
| Wire size | 0.13...2.08 mm² AWG 26...14 stranded wire |
| Screw terminal torque | 0.5 Nm |
| Supply voltage | 19.2...31.2 VDC |
| Fuse | 1.25 A SB / 250 VAC |
| Max. required power | ≤ 1.1 W / ≤ 1.9 W (1 ch. / 2 ch.) |
| Max. power dissipation | ≤ 0.8 W / ≤ 1.2 W (1 ch. / 2 ch.) |
| Input to any (Test/Working) | 2.6 kVAC / 300 VAC reinforced isolation |
| Analog output to supply | 2.6 kVAC / 300 VAC reinforced isolation |
| Status relay to supply | 1.5 kVAC / 150 VAC reinforced isolation |
| Response time (0...90%, 100...10%) | < 5 ms |
| Signal dynamics, input/output | Analog signal chain |
| SMART bi-directional communication | 0.5...7.5 kHz |
| Signal / noise ratio | > 60 dB |
| Accuracy | Better than 0.1% of selected range |
| mA, absolute accuracy | ≤ ±16 μA |
| mA, temperature coefficient | ≤ ±1.6 μA / °C |
| Measurement range | 3.5...23 mA |
| 2-wire transmitter supply 9106B1x (Uo = 27.5 VDC) | >16 V / 20 mA |
| 2-wire transmitter supply 9106B2x (Uo = 25.3 VDC) | >15 V / 20 mA |
| Sensor error detection: Loop break 4...20 mA | < 1 mA |
| Input voltage drop, supplied unit | < 4 V @ 23 mA |
| Input voltage drop, non-supplied unit | < 6 V @ 23 mA |
| Signal range | 3.5...23 mA |
| Load (@ current output) | ≤ 600 Ω |
| Load stability | ≤ 0.01% of span / 100 Ω |
| Current limit | ≤ 28 mA |
| Relay function | N.C. (Normally Closed) |
| Programmable low setpoint | 0...29.9 mA |
| Programmable high setpoint | 0...29.9 mA |
| Hysteresis for setpoints | 0.1 mA |
| ATEX | DEKRA 11ATEX0244 X |
| IECEx | DEK 11.0084X |
| UKEX | DEKRA 21UKEX0171X DEKRA 23UKEX0107X |
| FM US | FM16US0465X / FM16CA0213X |
| INMETRO | DEKRA 23.0003X |
| UL 61010-1 | E314307 |
| UL 913 | E233311 (only 9106xxx-U9) |
| CCC | 2020322309003231 |
| KCs | 21_AV4BO_0167X / 21_AV4BO_0168X (only 9106Bxx-KCs) |
| EAC Ex | EAEU KZ 7500361.01.01.08756 |
| DNV Marine | TAA00000JD |
| ClassNK | TA24034M |
| SIL Certification | SIL 2 / SIL 3 certified & fully assessed according to IEC 61508 |
| EMC | 2014/30/EU & UK SI 2016/1091 |
| LVD | 2014/35/EU & UK SI 2016/1101 |
| ATEX | 2014/34/EU & UK SI 2016/1107 |
| RoHS | 2011/65/EU & UK SI 2012/3032 |
| EAC | TR-CU 020/2011 |
| EAC Ex | TR-CU 012/2011 |
| EAC LVD | TR-CU 004/2011 |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Exporter,Trading Company,Seller
Year Established:
2018
Total Annual:
5000000-10000000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
.gtr-container-def789 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #1a1a19; line-height: 1.6; padding: 16px; max-width: 100%; box-sizing: border-box; overflow-wrap: break-word; } .gtr-container-def789 p { font-size: 14px;... .gtr-container-def789 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #1a1a19; line-height: 1.6; padding: 16px; max-width: 100%; box-sizing: border-box; overflow-wrap: break-word; } .gtr-container-def789 p { font-size: 14px;...
Get in touch with us
Leave a Message, we will call you back quickly!