China 10 kV/12 kV Dielectric Loss Tester for Transformer, CT PT, and Electrical
China 10 kV/12 kV Dielectric Loss Tester for Transformer, CT PT, and Electrical

  1. China 10 kV/12 kV Dielectric Loss Tester for Transformer, CT PT, and Electrical
  2. China 10 kV/12 kV Dielectric Loss Tester for Transformer, CT PT, and Electrical
  3. China 10 kV/12 kV Dielectric Loss Tester for Transformer, CT PT, and Electrical

10 kV/12 kV Dielectric Loss Tester for Transformer, CT PT, and Electrical

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Output Frequency 45 Hz / 55 Hz
Tan Delta Accuracy ±(Reading * 1% + 0.00040)
Delivery Time 30 Working Days
Voltage Setting Range 0.5–10 kV
Cx Accuracy ±(Reading * 1% + 1 pF)
Payment Terms L/C,T/T
Power Supply Type Variable-Frequency Power Supply
Packaging Details Plywood Case
Capacitance Range 3 pF–60000 pF
Model Number SXJS-III
Brand Name Sansion Power
Place of Origin China
Certification CE/SGS/EMS/ISO 9001

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Output Frequency 45 Hz / 55 Hz Tan Delta Accuracy ±(Reading * 1% + 0.00040)
Delivery Time 30 Working Days Voltage Setting Range 0.5–10 kV
Cx Accuracy ±(Reading * 1% + 1 pF) Payment Terms L/C,T/T
Power Supply Type Variable-Frequency Power Supply Packaging Details Plywood Case
Capacitance Range 3 pF–60000 pF Model Number SXJS-III
Brand Name Sansion Power Place of Origin China
Certification CE/SGS/EMS/ISO 9001
High Light 10 kV dielectric loss tester for transformers ,12 kV insulation testing equipment ,CT PT preventive maintenance tester

Product Description

SXJS-III Tan Delta Tester

This Tan Delta Tester provides capacitance and tan delta measurement for insulation condition testing of electrical equipment. It can be applied to transformers, CT and PT equipment, bushings, capacitors and surge arresters, making it suitable for power utilities, transformer manufacturers and electrical maintenance teams performing installation, commissioning, handover and preventive tests.

A variable-frequency power supply is used to improve measurement performance under practical power-system conditions. The tester automatically changes frequency and processes measurement data through its electronic control system, while 45 Hz and 55 Hz pure sine-wave outputs are available. With a 0.5–10 kV test voltage range and automatic voltage application, the instrument supports efficient dielectric loss testing without relying on a fixed-frequency power source.

Product Parameters

Parameter

Specification

Product Type

Tan Delta Tester

Voltage Setting Range

0.5–10 kV

Output Frequency

45 Hz / 55 Hz

Capacitance Range

3 pF–60000 pF

Cx Accuracy

±(Reading * 1% + 1 pF)

Tan Delta Accuracy

±(Reading * 1% + 0.00040)

Voltage Control

Automatic Voltage Application

Power Supply Type

Variable-Frequency Power Supply

Product Advantages

  • Wide Equipment Coverage — Supports dielectric loss testing for several types of high-voltage insulation equipment.
  • Pure Sine-Wave Output — Provides 45 Hz and 55 Hz pure sine-wave test signals for measurement.
  • Digital Measurement Technology — Uses microcontroller-based frequency conversion, A/D conversion and data calculation.
  • Practical Field Application — The design addresses dielectric loss measurement requirements where power-system interference can affect testing.

Application Scenarios

  1. Transformer manufacturing and maintenance testing
  2. CT and PT insulation condition testing
  3. Power substation preventive maintenance
  4. Electrical equipment installation and handover testing
  5. Power plant insulation diagnostics
  6. Electrical maintenance department testing

FAQ

Q1. What does a tan delta test measure?
A: The tester measures dielectric loss and capacitance parameters to evaluate the insulation condition of applicable electrical equipment.

Q2. Can this tester be used for CT and PT testing?
A: Yes. It is suitable for dielectric loss testing of instrument transformers.

Q3. What voltage can be applied during testing?
A: The voltage setting range is 0.5–10 kV, with automatic voltage application.

Q4. Why does the tester use variable-frequency technology?
A: Variable-frequency technology helps improve resistance to power-system interference and supports practical field dielectric loss measurements.

Q5. What accuracy is available for tan delta measurement?
A: The specified tan delta accuracy is ±(Reading * 1% + 0.00040).

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2005

  • Total Annual:

    50000000-80000000

  • Employee Number:

    120~150

  • Ecer Certification:

    Verified Supplier

Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...

+ Read More

Get in touch with us

  • Reach Us
  • Sansion Power Electric Co., Ltd.
  • Building 8, Yuanyuanxin Industrial Park, No. 8 Huanhu Middle Road, Dongxihu District, Wuhan, Hubei, China 43004
  • https://www.sansionpower.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement