China factories

Chat Now Send Email
China factory - Sansion Power Electric Co., Ltd.

Sansion Power Electric Co., Ltd.

  • China,Wuhan ,Hubei
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Portable 6 Phase Protective Relay Tester for Power Utilities and Electrical
China Portable 6 Phase Protective Relay Tester for Power Utilities and Electrical

  1. China Portable 6 Phase Protective Relay Tester for Power Utilities and Electrical
  2. China Portable 6 Phase Protective Relay Tester for Power Utilities and Electrical
  3. China Portable 6 Phase Protective Relay Tester for Power Utilities and Electrical

Portable 6 Phase Protective Relay Tester for Power Utilities and Electrical

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
AC Current Power 400 VA
AC Current Output 0-30 / 40 A per phase
AC Voltage Output 0-125 V
Delivery Time 30 Working Days
Time Measurement 0.1 ms-9999 s
Payment Terms L/C,T/T
Packaging Details Plywood Case
AC Current Frequency 20-500 Hz
DC Current Output 0-±10 A per phase
Model Number SXZB-6600
Brand Name Sansion Power
Certification CE/SGS/EMS/ISO 9001
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

AC Current Power 400 VA AC Current Output 0-30 / 40 A per phase
AC Voltage Output 0-125 V Delivery Time 30 Working Days
Time Measurement 0.1 ms-9999 s Payment Terms L/C,T/T
Packaging Details Plywood Case AC Current Frequency 20-500 Hz
DC Current Output 0-±10 A per phase Model Number SXZB-6600
Brand Name Sansion Power Certification CE/SGS/EMS/ISO 9001
Place of Origin China
High Light Portable 6 phase relay tester ,Protective relay tester for power utilities ,Relay tester with current voltage testing

Product Description

SXZB Series Relay Protection Test System

The SXZB Series Relay Protection Test System is developed for testing and commissioning protective relays and relay protection devices in power systems. It provides controllable AC and DC current and voltage signals, enabling engineers to simulate different electrical conditions during relay performance verification, commissioning and maintenance.

Built around a high-speed DSP processor, 16-bit DAC and high-power amplifier, the test system combines digital signal generation with computer-based control and timing measurement. Its industrial computer interface and rotary operation design allow users to configure test outputs, perform signal injection and monitor relay operating time for laboratory and field testing applications.

Product Parameters

Parameter

Value

Model

SXZB Series

AC Current Output

0–30 / 40 A per phase

AC Current Output Power

400 VA

AC Current Frequency Range

20–500 Hz

AC Current Harmonics

1–9th

DC Current Output

0–±10 A per phase

AC Voltage Output

0–125 V

AC Voltage Output Power

80 VA

DC Voltage Output Power

100 VA

AC Voltage Frequency Range

20–500 Hz

AC Voltage Harmonics

1–9th

DC Voltage Output Amplitude

0–±140 V

Switch Input

Dry Contact: 1–20 mA, 24 V

Potential Input

“0”: 0–6 V; “1”: +11–250 V

Switch Output

DC: 220 V / 0.2 A; AC: 220 V / 0.5 A

Time Measurement

0.1 ms–9999 s

Power Supply

AC 220 V ±10%, 50/60 Hz



Product Advantages

  • Flexible Test Outputs — AC and DC current and voltage outputs support various relay protection test requirements.
  • High-Speed Digital Processing — DSP-based architecture enables precise generation and control of test signals.
  • Integrated Time Measurement — Measures relay operating response from 0.1 ms to 9999 s.
  • Computer-Assisted Testing — Supports laptop connection for convenient testing and data control.
  • Compact Testing Platform — Combines signal output, control and measurement functions in one relay testing system.

Application Scenarios

  • Protective relay performance testing
  • Substation commissioning and maintenance
  • Power plant relay testing
  • Relay protection device inspection
  • Electrical testing laboratories
  • Power system maintenance projects

FAQ

1. What equipment can be tested with the SXZB system?
It is designed for protective relays, relay protection devices and related power system protection equipment.

2. Does the system support both AC and DC testing?
Yes. It provides AC and DC current and voltage outputs for different relay test conditions.

3. What is the timing measurement range?
The timing measurement range is 0.1 ms to 9999 s.

4. Can it be operated through a computer?
Yes. The system can be connected to a laptop for computer-assisted testing and operation.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2005

  • Total Annual:

    50000000-80000000

  • Employee Number:

    120~150

  • Ecer Certification:

    Verified Supplier

Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...

+ Read More

Get in touch with us

  • Reach Us
  • Sansion Power Electric Co., Ltd.
  • Building 8, Yuanyuanxin Industrial Park, No. 8 Huanhu Middle Road, Dongxihu District, Wuhan, Hubei, China 43004
  • https://www.sansionpower.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement