| Maximum TDH | 442 m (1,450 ft) |
| Motor Power | 56 kW (75 HP) |
| Impeller Type | Open, Single-Stage, CFD-Optimized |
| Casing Material | Carbon Steel / 316 SS |
| Packaging Details | Export Plywood Case, VCI Anti-Rust, Desiccant Packs |
| Seal System | API 682 Single Cartridge |
| Temperature Range | -130°C to +260°C |
| Application | Boiler Feed, Utility, Power Generation |
| Delivery Time | 60 Days |
| Supply Ability | 12 Sets per Month |
| Maximum Flow | 57 m³/h (250 GPM) |
| Payment Terms | T/T,L/C |
| Design Code | API 610 OH6 |
| Place of Origin | China |
| Model Number | HHLF-BF442 |
| Certification | ISO 9001:2015, API 610, CE |
| Brand Name | Sunstrand |
View Detail Information
Explore similar products
LMV331 Replacement High Speed Centrifugal Pump 315 kW API 610 OH6 Vertical
Amine Gas Sweetening H2S Removal High Speed Centrifugal Pump for Refinery
API 610 OH6 Integrally Geared Vertical High Speed Centrifugal Pump 316 SS
High Temperature Thermal Oil High Speed Centrifugal Pump 350°C Heat Transfer
Product Specification
| Maximum TDH | 442 m (1,450 ft) | Motor Power | 56 kW (75 HP) |
| Impeller Type | Open, Single-Stage, CFD-Optimized | Casing Material | Carbon Steel / 316 SS |
| Packaging Details | Export Plywood Case, VCI Anti-Rust, Desiccant Packs | Seal System | API 682 Single Cartridge |
| Temperature Range | -130°C to +260°C | Application | Boiler Feed, Utility, Power Generation |
| Delivery Time | 60 Days | Supply Ability | 12 Sets per Month |
| Maximum Flow | 57 m³/h (250 GPM) | Payment Terms | T/T,L/C |
| Design Code | API 610 OH6 | Place of Origin | China |
| Model Number | HHLF-BF442 | Certification | ISO 9001:2015, API 610, CE |
| Brand Name | Sunstrand | ||
| High Light | High Head Low Flow Pump ,Boiler Feed Centrifugal Pump ,Vertical Process Feed Pump | ||
Having supplied boiler feed pump packages to independent power producers and industrial cogeneration facilities since 2012, our engineering team has accumulated direct operational feedback from over 80 boiler feed water installations that informs every aspect of this high head low flow vertical centrifugal pump design.
The OH6 integrally geared architecture was specifically selected for boiler feed applications after our reliability analysis of field maintenance records demonstrated that the single-stage geared configuration achieves a mean time between overhaul of 25,000+ hours compared to 12,000-16,000 hours for conventional ring-section multi-stage pumps operating under equivalent service conditions.
This reliability data, collected through our structured aftermarket service reporting system, validates the fundamental advantage of eliminating inter-stage bushings, multiple wear ring sets, and balance drum leakage paths—the dominant failure modes identified in our root cause analysis database of multi-stage boiler feed pump incidents.
At our manufacturing facility, each boiler feed pump casing undergoes hydrostatic pressure testing to 1.5 times the maximum allowable working pressure with the pressure decay rate monitored and recorded over a 30-minute stabilization period, exceeding the API 610 minimum requirement.
The precision-ground helical gear set is manufactured from case-hardened 18CrNiMo7-6 alloy steel with tooth flank surface finish below 0.4 µm Ra, verified by profilometer measurement after finish grinding. Following gearbox assembly, tooth contact patterns are checked under light load using marking compound and documented photographically in the assembly record.
The complete pump-motor assembly is then subjected to a mechanical running test for a minimum of 4 continuous hours with vibration measurements taken at the bearing housings using calibrated accelerometers per API 610 acceptance criteria.
| Parameter | Specification | Verification |
|---|---|---|
| Maximum Flow Rate | 57 m³/h (250 GPM) at 60 Hz | Magnetic flow meter, calibration certificate provided |
| Maximum Total Dynamic Head | 442 m (1,450 ft) | Deadweight-tested pressure transmitters |
| Motor Power Rating | 56 kW (75 HP), 2-pole IEC frame | Torque meter measurement during string test |
| Design Standard | API 610 12th Ed., OH6 Category | Design review checklist documented |
| Max Working Pressure | 10.0 MPa (1,440 psi) at 38°C | Hydrostatic test report with pressure-time data |
| Fluid Temperature Limits | -130°C to +260°C (-200°F to +500°F) | Material selection per API 610 Table 2 |
| Materials Available | Carbon Steel (S-5), 316 SS (A-8), Duplex | PMI verified, EN 10204 3.1 certificates |
| Seal Configuration | API 682 4th Ed. Cartridge Single (Plan 11/13) | Air test at 1.0 bar(g), seal chamber dimensions |
| NPSHr at BEP | Optimized inducer for low NPSHa conditions | 3% head drop method, witnessed test data |
| Bearing Design Life | L10h ≥ 25,000 hours at rated conditions | Calculated per ISO 281, verified by teardown inspection |
Company Details
Business Type:
Manufacturer
Year Established:
2009
Total Annual:
10000000-20000000
Employee Number:
200~300
Ecer Certification:
Verified Supplier
1. 18 Years of Engineering Heritage (Experience) With 18 years of specialized experience in the flow control industry, Sunstrand Fluid Handling has evolved into a cornerstone of high-performance pumping solutions. We specialize in addressing the most demanding "High-Head, Low-Flow" challenges, provi... 1. 18 Years of Engineering Heritage (Experience) With 18 years of specialized experience in the flow control industry, Sunstrand Fluid Handling has evolved into a cornerstone of high-performance pumping solutions. We specialize in addressing the most demanding "High-Head, Low-Flow" challenges, provi...
Get in touch with us
Leave a Message, we will call you back quickly!