China factories

Chat Now Send Email
China factory - Sansion Power Electric Co., Ltd.

Sansion Power Electric Co., Ltd.

  • China,Wuhan ,Hubei
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Custom GIS High Voltage Testing System Manufacturer, AC Withstand Voltage and
China Custom GIS High Voltage Testing System Manufacturer, AC Withstand Voltage and

  1. China Custom GIS High Voltage Testing System Manufacturer, AC Withstand Voltage and
  2. China Custom GIS High Voltage Testing System Manufacturer, AC Withstand Voltage and
  3. China Custom GIS High Voltage Testing System Manufacturer, AC Withstand Voltage and

Custom GIS High Voltage Testing System Manufacturer, AC Withstand Voltage and

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Frequency 50Hz/60Hz
Cooling method Air cooling
Capacity Range 50–2000kVA
Delivery Time 30 working days
Payment Terms L/C,T/T
Power consumption 500W
Packaging Details Plywood Case
System Type Resonance voltage generation
Input Voltage 0.35–10kV
Model Number SXGTU
Brand Name Sansion Power
Certification CE/SGS/EMS/ISO 9001
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Frequency 50Hz/60Hz Cooling method Air cooling
Capacity Range 50–2000kVA Delivery Time 30 working days
Payment Terms L/C,T/T Power consumption 500W
Packaging Details Plywood Case System Type Resonance voltage generation
Input Voltage 0.35–10kV Model Number SXGTU
Brand Name Sansion Power Certification CE/SGS/EMS/ISO 9001
Place of Origin China
High Light GIS high voltage testing system ,AC withstand voltage test equipment ,partial discharge test equipment for GIS
Product Description

The Custom GIS High Voltage Testing System is a project-based solution for customers who need a complete GIS insulation testing system.

Instead of using a standard product configuration, the equipment can be engineered according to:

  • GIS rated voltage
  • Required AC test voltage
  • GIS capacitance
  • Test duration
  • Frequency range
  • PD measurement requirement
  • Factory or site application
  • Laboratory dimensions
  • Available power supply
  • Applicable standards
Complete System Configuration

A typical system may include:

Variable Frequency Power Supply

↓

Excitation Transformer

↓

High Voltage Reactor

↓

GIS Test Object

↓

Voltage Divider

↓

Partial Discharge Coupling & Measuring System

↓

Digital Control & Data Acquisition

The exact configuration depends on the test object and project specification.

Main Testing Functions
  • GIS AC withstand test
  • GIL AC withstand test
  • Partial discharge test
  • PD inception voltage
  • PD extinction voltage
  • High-voltage measurement
  • Variable-frequency resonance
  • Automatic voltage regulation
  • Test duration control
  • Digital data acquisition
  • Test report generation
Ideal Customers
  • GIS manufacturers
  • GIL manufacturers
  • Power utilities
  • EPC contractors
  • Substation contractors
  • High-voltage testing companies
  • Research institutes
  • Certification laboratories
What Customers Usually Want to Know

1. Can you design the system according to our GIS?

Yes. The technical proposal should be based on the actual GIS electrical parameters.

2. Can you provide a complete solution rather than individual equipment?

Yes. The solution can include the AC resonant system, PD measurement, voltage divider, control system, safety protection and related accessories.

3. Can you provide technical documents?

A project package can include technical specifications, system configuration, drawings, operation manuals, test procedures and relevant documentation according to the contract.

4. Can you support FAT and commissioning?

Factory acceptance testing and installation/commissioning support can be included according to the project scope.

FAQ

Q: What information should I send for a quotation?

A: Please provide:

  1. GIS rated voltage
  2. Required AC test voltage
  3. GIS capacitance
  4. Number of GIS bays
  5. Test duration
  6. Required frequency range
  7. Partial discharge test requirement
  8. Applicable IEC/IEEE/GB standard
  9. Factory or on-site application
  10. Available power supply
  11. Laboratory/site dimensions
  12. Required test report format

Q: Can you provide a complete GIS testing laboratory solution?

A: Yes. A complete project can combine AC withstand, PD, circuit breaker, contact resistance and SF6-related testing equipment.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2005

  • Ecer Certification:

    Verified Supplier

Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...

+ Read More

Get in touch with us

  • Reach Us
  • Sansion Power Electric Co., Ltd.
  • Building 8, Yuanyuanxin Industrial Park, No. 8 Huanhu Middle Road, Dongxihu District, Wuhan, Hubei, China 43004
  • https://www.transformertestsystem.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement