China High Voltage Series Resonance Test System Built for Power Plant GIS Substation
China High Voltage Series Resonance Test System Built for Power Plant GIS Substation

  1. China High Voltage Series Resonance Test System Built for Power Plant GIS Substation
  2. China High Voltage Series Resonance Test System Built for Power Plant GIS Substation
  3. China High Voltage Series Resonance Test System Built for Power Plant GIS Substation

High Voltage Series Resonance Test System Built for Power Plant GIS Substation

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
System Components 5 (Control, Power Supply, Transformer, Reactor, Divider)
Delivery Time 30 Working Days
Rated Voltage 500 kV
Frequency Type Variable Frequency
Test Type AC Withstand Voltage
Rated Capacity 2000 kVA
Input Supply Reduced Reactive Power
Payment Terms L/C,T/T
Operating Frequency Adjustable
Packaging Details Plywood Case
Resonance Mode Series Resonance
Model Number SXBP
Certification CE/SGS/EMS/ISO 9001
Brand Name Sansion Power
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

System Components 5 (Control, Power Supply, Transformer, Reactor, Divider) Delivery Time 30 Working Days
Rated Voltage 500 kV Frequency Type Variable Frequency
Test Type AC Withstand Voltage Rated Capacity 2000 kVA
Input Supply Reduced Reactive Power Payment Terms L/C,T/T
Operating Frequency Adjustable Packaging Details Plywood Case
Resonance Mode Series Resonance Model Number SXBP
Certification CE/SGS/EMS/ISO 9001 Brand Name Sansion Power
Place of Origin China
High Light High Voltage Series Resonance Test System ,GIS Substation On-site Testing Solution ,Power Cable Maintenance Test System

SXBP 2000KVA/500kV Variable Frequency AC Resonant Test System

Product Description

A Variable Frequency AC Resonant Test System applies the principle of series resonance to high-voltage AC withstand testing. By adjusting the operating frequency to suit the test circuit, it provides a method for testing the insulation of compatible high-voltage electrical equipment.

GIS manufacturers, switchgear factories, substation contractors, and electrical testing departments may consider this type of equipment for suitable insulation withstand tests. Before selecting a system, users should identify the equipment under test, the required testing procedure, and the electrical characteristics of the test object.

Product Components

  • Control System
  • Variable Frequency Power Supply
  • Excitation Transformer
  • Resonant Reactor
  • Voltage Divider

Product Features and Applications

  • GIS AC withstand voltage testing
  • High-voltage switchgear insulation testing
  • Substation electrical equipment AC testing
  • High-voltage AC resonant test equipment
  • Variable frequency series resonance testing
  • Insulation withstand testing for compatible GIS equipment
  • Switchgear factory testing and electrical commissioning test applications
  • High-voltage testing solutions for transmission and distribution equipment
  • AC withstand test equipment for electrical manufacturers and service contractors
  • System suitability assessed according to the test object and testing procedure

FAQ

Q1: What is GIS AC withstand testing?

GIS AC withstand testing is used to evaluate the insulation performance of gas-insulated switchgear under specified test conditions. The required test method depends on the equipment design and applicable testing procedure.

Q2: Why consider a series resonance test system for GIS?

The resonance method can reduce the reactive power required from the input supply when the test circuit and system are suitably matched. This makes it a method worth evaluating for compatible high-voltage AC tests.

Q3: Can the system be used for switchgear insulation testing?

It may be suitable for certain switchgear AC withstand tests. The switchgear type, test connections, required test voltage, and applicable procedure must be reviewed before confirming compatibility.

Q4: Is resonant testing relevant to substation projects?

It can be considered for compatible high-voltage testing tasks at substations. The application depends on the equipment being tested, site conditions, and project requirements.

Q5: What should be confirmed before purchasing GIS test equipment?

Confirm the equipment type, insulation test procedure, test object characteristics, site arrangement, and project requirements. These details help determine whether the proposed AC resonant test system is suitable.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2005

  • Ecer Certification:

    Verified Supplier

Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...

+ Read More

Get in touch with us

  • Reach Us
  • Sansion Power Electric Co., Ltd.
  • Building 8, Yuanyuanxin Industrial Park, No. 8 Huanhu Middle Road, Dongxihu District, Wuhan, Hubei, China 43004
  • https://www.transformertestsystem.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement