China GIS Partial Discharge Test System for SF6 Gas-Insulated Switchgear AC Withstand
China GIS Partial Discharge Test System for SF6 Gas-Insulated Switchgear AC Withstand

  1. China GIS Partial Discharge Test System for SF6 Gas-Insulated Switchgear AC Withstand
  2. China GIS Partial Discharge Test System for SF6 Gas-Insulated Switchgear AC Withstand
  3. China GIS Partial Discharge Test System for SF6 Gas-Insulated Switchgear AC Withstand

GIS Partial Discharge Test System for SF6 Gas-Insulated Switchgear AC Withstand

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Delivery Time 30 Working Days
HV Generation Transformer / Series Resonance
Model SXGTU
Main Test Partial Discharge / AC Withstand
Primary Voltage 0.35–10 kV
Capacity 50–2000 kVA
Payment Terms L/C,T/T
PD Level 1–3 pC
Packaging Details Plywood Case
Resonance Type Power Frequency / Variable Frequency
Rated Voltage 100, 200, 250, 300, 500, 800, 1000 kV
Brand Name Sansion Power
Model Number SXGTU
Place of Origin China
Certification CE/SGS/EMS/ISO 9001

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Delivery Time 30 Working Days HV Generation Transformer / Series Resonance
Model SXGTU Main Test Partial Discharge / AC Withstand
Primary Voltage 0.35–10 kV Capacity 50–2000 kVA
Payment Terms L/C,T/T PD Level 1–3 pC
Packaging Details Plywood Case Resonance Type Power Frequency / Variable Frequency
Rated Voltage 100, 200, 250, 300, 500, 800, 1000 kV Brand Name Sansion Power
Model Number SXGTU Place of Origin China
Certification CE/SGS/EMS/ISO 9001
High Light GIS partial discharge test system ,SF6 gas-insulated switchgear testing ,AC withstand voltage test equipment

Product Description

SXGTU GIS Partial Discharge Withstand Voltage Test Device

The SXGTU is a high voltage test system designed to evaluate the insulation condition of Gas Insulated Switchgear through partial discharge and AC withstand tests. It is suitable for GIS manufacturers, power equipment testing centers and high voltage laboratories where controlled electrical stress and low background discharge are required.

The high voltage components are enclosed in a sealed and shielded structure to improve operational safety and reduce the influence of external interference. At rated voltage, the overall partial discharge can be controlled within 1–3 pC under normal conditions. Depending on the required test configuration, the system can generate high voltage through a test transformer or series resonance circuit.

Product Parameters

Parameter Specification
Model SXGTU
Main Test Partial Discharge / AC Withstand
Test Object GIS / High Voltage Electrical Equipment
Rated Voltage Options 100, 200, 250, 300, 500, 800, 1000 kV
Capacity 50–2000 kVA
Primary Voltage 0.35–10 kV
PD Level 1–3 pC
HV Generation Transformer / Series Resonance
Resonance Power Frequency / Variable Frequency
Boosting Single Stage

Product Advantages

  1. The system is optimized for high voltage tests where partial discharge control is important.
  2. A sealed high voltage structure helps isolate the energized section from the external environment.
  3. Different high voltage generation methods allow the system to match various GIS test arrangements.
  4. The equipment can be configured for different voltage and capacity levels.

Application Scenarios

  • GIS partial discharge measurement
  • GIS dielectric testing
  • SF6 insulated switchgear testing
  • High voltage insulation verification
  • GIS quality control laboratory
  • Electrical equipment acceptance testing

FAQ

Q1: Why is low partial discharge important for GIS testing?
A1: Low background partial discharge helps reduce interference during insulation evaluation and supports reliable test measurements.

Q2: What is the standard partial discharge performance?
A2: The system can achieve 1–3 pC at rated voltage under normal environmental conditions.

Q3: Does the system only test GIS?
A3: GIS is the primary application, while the system can also be configured for other high voltage electrical equipment.

Q4: What series resonance options are available?
A4: Both power-frequency and variable-frequency series resonance configurations can be provided.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2005

  • Ecer Certification:

    Verified Supplier

Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...

+ Read More

Get in touch with us

  • Reach Us
  • Sansion Power Electric Co., Ltd.
  • Building 8, Yuanyuanxin Industrial Park, No. 8 Huanhu Middle Road, Dongxihu District, Wuhan, Hubei, China 43004
  • https://www.transformertestsystem.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement