SF6 GIS Partial Discharge and AC Withstand Test System for High Voltage

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Partial Discharge 1–3 pC at Rated Voltage
Delivery Time 30 Working Days
Voltage Level 100 kV, 200 kV, 250 kV, 300 kV, 500 kV, 800 kV, 1000 kV
Capacity 50–2000 kVA
Voltage Boosting Single Stage
Resonance Power Frequency / Variable Frequency
Primary Voltage 0.35–10 kV
Payment Terms L/C,T/T
Temperature Rise ≤65 K at Rated Current for 60 Minutes at 50 Hz
Packaging Details Plywood Case
High Voltage Generation High Voltage Transformer / Series Resonance
Brand Name Sansion Power
Model Number SXGTU
Place of Origin China
Certification CE/SGS/EMS/ISO 9001

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Partial Discharge 1–3 pC at Rated Voltage Delivery Time 30 Working Days
Voltage Level 100 kV, 200 kV, 250 kV, 300 kV, 500 kV, 800 kV, 1000 kV Capacity 50–2000 kVA
Voltage Boosting Single Stage Resonance Power Frequency / Variable Frequency
Primary Voltage 0.35–10 kV Payment Terms L/C,T/T
Temperature Rise ≤65 K at Rated Current for 60 Minutes at 50 Hz Packaging Details Plywood Case
High Voltage Generation High Voltage Transformer / Series Resonance Brand Name Sansion Power
Model Number SXGTU Place of Origin China
Certification CE/SGS/EMS/ISO 9001
High Light SF6 GIS partial discharge test system ,AC withstand test system for high voltage equipment ,gas insulated switchgear insulation testing

Product Description

SXGTU GIS Partial Discharge Withstand Voltage Test Device

The SXGTU GIS Partial Discharge and AC Withstand Test System is designed for high voltage insulation testing. The high voltage section is fully sealed inside a shielded space, providing a safer and more reliable test structure. The overall partial discharge can be controlled within 1–3 pC at rated voltage under normal environmental conditions.

The system is available in voltage levels from 100 kV to 1000 kV and capacities from 50 kVA to 2000 kVA. High voltage can be generated through a high voltage transformer or series resonance at power frequency or variable frequency. All voltage boosting methods use single-stage boosting without cascade connection. The compact structure requires less installation space and offers convenient connection with the test object.

Product Parameters

Parameter

Specification

Model

SXGTU

Voltage Level

100 kV, 200 kV, 250 kV, 300 kV, 500 kV, 800 kV, 1000 kV

Capacity

50–2000 kVA

High Voltage Generation

High Voltage Transformer / Series Resonance

Resonance

Power Frequency / Variable Frequency

Voltage Boosting

Single Stage

Primary Voltage

0.35–10 kV

Partial Discharge

1–3 pC at Rated Voltage

Temperature Rise

≤65 K at Rated Current for 60 Minutes at 50 Hz

Product Advantages

  1. The high voltage section is fully sealed within a shielded space for safer testing.
  2. The overall partial discharge can be controlled within 1–3 pC at rated voltage under normal conditions.
  3. The compact structure occupies less space and uses lightweight components.
  4. The internal high voltage isolation switch enables one system to support multiple testing arrangements.

Application Scenarios

  • GIS high voltage testing
  • Partial discharge testing
  • AC withstand testing
  • High voltage insulation testing
  • Electrical equipment testing

FAQ

Q1: What voltage levels are available?
A1: The available voltage levels are 100 kV, 200 kV, 250 kV, 300 kV, 500 kV, 800 kV and 1000 kV.

Q2: What is the partial discharge level?
A2: The overall partial discharge can be controlled within 1–3 pC at rated voltage under normal environmental conditions.

Q3: What voltage boosting methods are available?
A3: The system supports high voltage transformer boosting and series resonance.

Q4: Does the system require cascade boosting?
A4: No. All voltage boosting methods use single-stage voltage boosting without cascade connection.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2005

  • Ecer Certification:

    Verified Supplier

Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...

+ Read More

Get in touch with us

  • Reach Us
  • Sansion Power Electric Co., Ltd.
  • Building 8, Yuanyuanxin Industrial Park, No. 8 Huanhu Middle Road, Dongxihu District, Wuhan, Hubei, China 43004
  • https://www.transformertestsystem.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement