| Boosting Method | Single Stage |
| Delivery Time | 30 Working Days |
| Voltage Level | 100–1000 kV |
| Capacity | 50–2000 kVA |
| HV Generation | High Voltage Transformer / Series Resonance |
| Partial Discharge | 1–3 pC at Rated Voltage |
| Resonance Mode | Power Frequency / Variable Frequency |
| Payment Terms | L/C,T/T |
| Temperature Rise | ≤65 K |
| Packaging Details | Plywood Case |
| Input Voltage | 0.35–10 kV |
| Brand Name | Sansion Power |
| Model Number | SXGTU |
| Place of Origin | China |
| Certification | CE/SGS/EMS/ISO 9001 |
View Detail Information
Explore similar products
GIS Partial Discharge Free AC Withstand Voltage Test System, Gas Insulated High
Portable and On-Site GIS High Voltage Testing System with Partial Discharge
GIS High Voltage AC Withstand Voltage and Partial Discharge Test Equipment,
GIS Partial Discharge and AC Withstand Voltage Test System, High Voltage GIS
Product Specification
| Boosting Method | Single Stage | Delivery Time | 30 Working Days |
| Voltage Level | 100–1000 kV | Capacity | 50–2000 kVA |
| HV Generation | High Voltage Transformer / Series Resonance | Partial Discharge | 1–3 pC at Rated Voltage |
| Resonance Mode | Power Frequency / Variable Frequency | Payment Terms | L/C,T/T |
| Temperature Rise | ≤65 K | Packaging Details | Plywood Case |
| Input Voltage | 0.35–10 kV | Brand Name | Sansion Power |
| Model Number | SXGTU | Place of Origin | China |
| Certification | CE/SGS/EMS/ISO 9001 | ||
| High Light | GIS gas-insulated switchgear test system ,AC high voltage withstand test equipment ,electrical insulation test system | ||
SXGTU GIS Partial Discharge Withstand Voltage Test Device
The SXGTU GIS High Voltage Test System features a sealed and shielded high voltage structure for high voltage testing applications. By enclosing the high voltage section in one shielded space, the system provides a reliable test arrangement while keeping the overall partial discharge within 1–3 pC at rated voltage under normal environmental conditions.
The equipment has a compact structure with lightweight components, allowing it to occupy a smaller installation area. It can generate high voltage through a high voltage transformer or series resonance, including power-frequency and variable-frequency operation. The system uses single-stage voltage boosting and does not require cascade voltage boosting. The test object can be connected directly to the system for convenient testing.
| Parameter | Specification |
|---|---|
| Model | SXGTU |
| Product Type | GIS High Voltage Test System |
| Voltage Level | 100–1000 kV |
| Capacity | 50–2000 kVA |
| Input Voltage | 0.35–10 kV |
| Partial Discharge | 1–3 pC at Rated Voltage |
| HV Generation | High Voltage Transformer / Series Resonance |
| Resonance Mode | Power Frequency / Variable Frequency |
| Boosting Method | Single Stage |
| Temperature Rise | ≤65 K |
Q1: What is the specified partial discharge level?
A1: It is controlled within 1–3 pC at rated voltage under normal environmental conditions.
Q2: What is the input voltage range?
A2: The primary input voltage range is 0.35–10 kV.
Q3: What is the standard capacity range?
A3: The capacity range is 50–2000 kVA.
Q4: Can the equipment be customized?
A4: Yes. Higher voltage and capacity levels can be customized.
Company Details
Business Type:
Manufacturer
Year Established:
2005
Ecer Certification:
Verified Supplier
Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...