Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"AC High Voltage Variable Frequency Series Resonant Test System for Power","imgUrl":"https:\/\/img.chinax.com\/nimg\/79\/8a\/9c12cb017cf7b32bad9747c49d59-200x200-1\/ac_high_voltage_variable_frequency_series_resonant_test_system_for_power.jpg","attrs":{"Frequency Resolution":"0.01Hz","Model Number":"SXBP","Quality Factor":"\u226520 at Full Load","Minimum Order Quantity":"1 Set"}}
{"title":"Portable Modular Variable Frequency Series Resonance Test System with Automatic","imgUrl":"https:\/\/img.chinax.com\/nimg\/06\/f7\/df1bbef17b3eab15560593e5edfe-200x200-1\/portable_modular_variable_frequency_series_resonance_test_system_with_automatic_test_function_and_multi_layer_safety_protection_se.jpg","attrs":{"Delivery Time":"30 Working Days","Model Number":"SXBP","Output Frequency Range":"20\uff5e300Hz","Minimum Order Quantity":"1 Set"}}
{"title":"Variable Frequency Series Resonance AC Withstand Voltage Testing System for High","imgUrl":"https:\/\/img.chinax.com\/nimg\/d5\/59\/51c02a72292d004b324ea1423f9c-200x200-1\/variable_frequency_series_resonance_ac_withstand_voltage_testing_system_for_high_voltage_electrical_insulation_assessment.jpg","attrs":{"Model Number":"SXBP","Frequency Regulation Resolution":"0.01Hz adjustment step, stability \u22640.01%","Minimum Order Quantity":"1 Set","Working Power Supply":"Input: AC 220V 1-phase or AC 380V 3-phase"}}
{"title":"High Voltage Variable Frequency Series Resonance Test System for GIS, Transforme","imgUrl":"https:\/\/img.chinax.com\/nimg\/9e\/35\/1161d0d539481720deb4c6c786af-200x200-1\/high_voltage_variable_frequency_series_resonance_test_system_for_gis_2c_transformer_2c_busbar_and_substation_equipment_insulation_.jpg","attrs":{"Rated Test Voltage":"200 kV - 2,000 kV","Model Number":"SXBP","Waveform Distortion Rate":"\u2264 1%","Minimum Order Quantity":"1 Set"}}
{"title":"High Voltage Variable Frequency Series Resonance Test System High Voltage AC","imgUrl":"https:\/\/img.chinax.com\/nimg\/23\/89\/325af8ef12c0ded14ae7e844df57-200x200-1\/high_voltage_variable_frequency_series_resonance_test_system_high_voltage_ac_resonant_test_set.jpg","attrs":{"Rated Test Voltage":"200 kV - 2,000 kV","Model Number":"SXBP","Frequency Resolution":"0.1 Hz","Minimum Order Quantity":"1 Set"}}
{"title":"20\u2013300 Hz 108kV Modular Structure Series Resonant Test System for AC Resonant","imgUrl":"https:\/\/img.chinax.com\/nimg\/81\/5c\/0c55ff8c402b3f40241e316d455f-200x200-1\/20_e2_80_93300_hz_108kv_modular_structure_series_resonant_test_system_for_ac_resonant_test_system_stator_insulation_testing.jpg","attrs":{"Model Number":"SXBP","Frequency Range":"20\u2013300 Hz","Minimum Order Quantity":"1","Test Type":"AC withstand voltage"}}
{"title":"Variable Frequency High Voltage Test System , On Site AC Withstand Hipot Test","imgUrl":"https:\/\/img.chinax.com\/nimg\/d8\/72\/2b33b9f31c427d4db2bdaa4e0bcd-200x200-1\/variable_frequency_high_voltage_test_system_2c_on_site_ac_withstand_hipot_test_equipment.jpg","attrs":{"Model Number":"SXBP","Rated Capacity Range":"300 kVA up to 20000 kVA for diversified on-site test loads","Minimum Order Quantity":"1 Set","Input Power Condition":"380V, dual-frequency 50Hz\/60Hz"}}
The SXBP Series Variable Frequency Resonant Test System is developed for high-voltage AC insulation testing where reliable test voltage generation, load adaptability and flexible equipment configuration are essential. Designed around variable-frequency resonance technology, the system combines a frequency conversion power supply, excitation transformer, resonant reactors and a control and measurement unit. The configuration can be selected according to the electrical characteristics of the test object and the required test conditions.
Typical system components
Variable Frequency Power Supply
Excitation Transformer
Resonant Reactors
Control and Measurement Unit
Key Advantages
Configuration Based on Actual LoadThe system selection process considers the electrical characteristics of the test object rather than the voltage rating alone. This supports more appropriate equipment matching for different applications.
Modular System ArrangementThe use of separate functional components provides flexibility when configuring the equipment for different test voltage and load requirements.
Adjustable-Frequency TestingVariable-frequency operation supports resonance matching within the specified operating range, helping accommodate different capacitive loads.
Practical Equipment HandlingThe catalogue describes a lightweight component design, with certain components weighing approximately 50 kg or less. Actual weight and handling requirements vary by model and component rating.
Application-Specific Technical EvaluationThe final configuration can be assessed against project requirements, including the required test voltage, capacitance, test duration and applicable standards.
Applications
Power Cable Insulation Testing
GIS and Switchgear Testing
Transformer Testing
Other Electrical Apparatus
FAQ
1. How is the resonant reactor configuration determined?
The resonant reactor configuration depends on the required test voltage, test-object capacitance, operating frequency and system rating. The manufacturer evaluates these parameters to determine a suitable reactor arrangement for the intended application.
2. Does the maximum output voltage determine the system's testing capacity?
No. Maximum output voltage is only one factor in system selection. Rated capacity, output current, test-object capacitance, operating frequency and test duration must also be considered. The complete configuration should be evaluated against the actual test requirements.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer
Year Established:
2005
Ecer Certification:
Verified Supplier
Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot... Sansion Power Electric Co., Ltd was established in 2005, a technocrat who have rich experience of more than 10 years in R&D, manufacturing and marketing of power electrical testing products, which are widely used in the fields of power electric, railroad, energy conservation and environment prot...