{"title":"0.1mW Oxidation Induction Time Test Machine For Plastic Analysis","imgUrl":"https:\/\/img.chinax.com\/nimg\/3e\/c2\/1843af8e2e742c0598639b6bf757-200x200-1\/0_1mw_oxidation_induction_time_test_machine_for_plastic_analysis.jpg","attrs":{"Brand Name":"JINHAIHU","Model Number":"DSC-500A","Certification":"ISO9001","Place of Origin":"BEIJING, CHINA"}}
{"title":"Plastic DSC Differential Scanning Calorimetry 500mw For Glass Transition","imgUrl":"https:\/\/img.chinax.com\/nimg\/fd\/8f\/93aa3718ff74ecb356bf34e35666-200x200-1\/plastic_dsc_differential_scanning_calorimetry_500mw_for_glass_transition_temperature.jpg","attrs":{"Brand Name":"JINHAIHU","Model Number":"DSC-1150B","Certification":"ISO","Place of Origin":"BEIJING, CHINA"}}
{"title":"Determination Glass Transition Temperature Differential Scanning Calorimetry","imgUrl":"https:\/\/img.chinax.com\/nimg\/b0\/fa\/ab3199bdcc30f56a9a33c8042c73-200x200-1\/determination_glass_transition_temperature_differential_scanning_calorimetry_machine_dsc.jpg","attrs":{"Brand Name":"JINHAIHU","Model Number":"DSC-500A","Certification":"ISO9001","Place of Origin":"BEIJING, CHINA"}}
Industrial Differential Scanning Calorimeter Featuring Widescreen Touch Interface for Accurate Polymer Oxidation Induction Period Measurement
Summary:
This DSC (Differential Scanning Calorimeter) features a touchscreen interface, specifically engineered for the oxidation induction period (OIT) testing of polymeric materials. It supports one-key operation for users and full software automation—streamlining testing workflows and ensuring consistent, error-free operation.
The instrument fully complies with the following international and national standards:
GB/T 19466.2-2009 / ISO 11357-2:1999
GB/T 19466.3-2009 / ISO 11357-3:1999
GB/T 19466.6-2009 / ISO 11357-6:1999
Features:
Industrial-Grade Widescreen Touch Interface
Boasts an information-rich display presenting comprehensive real-time data, including set temperature, sample temperature, oxygen flow rate, nitrogen flow rate, differential thermal signal, and various switch statuses—facilitating intuitive monitoring and operation.
Universal USB Communication Interface
Features high universality and reliable data transmission, with built-in self-recovering connection functionality. This ensures stable communication with external devices and minimizes interruptions during testing.
Compact Furnace with Adjustable Thermal Rates
Adopts a compact furnace structure, supporting stepless adjustment of heating and cooling rates to meet the thermal cycle requirements of different polymeric material OIT tests.
Equipped with an improved installation process and adopts a mechanical fastening method. This completely eliminates contamination of the differential thermal signal caused by internal furnace colloid, ensuring the accuracy of test data.
Efficient Heating & Cooling System
The furnace utilizes electric heating wires for heating and circulating cooling water (compressor-refrigerated) for cooling. It features a compact structure and small footprint, saving laboratory space while ensuring efficient thermal regulation.
High-Precision Temperature Control
Dual temperature probes guarantee excellent repeatability of sample temperature measurement. Specialized temperature control technology is employed to regulate the furnace wall temperature, thereby achieving precise control of the sample’s set temperature.
Automatic Gas Channel Switching
The gas flow meter enables automatic switching between two gas channels, with fast switching speed and short stabilization time—ensuring consistent gas atmosphere conditions during testing.
Standard Reference Samples for Calibration
Comes with standard reference samples, facilitating convenient calibration of temperature coefficients and enthalpy coefficients to maintain long-term testing accuracy.
Versatile Software Compatibility
The software supports screens of all resolutions, automatically adjusting the computer screen size and curve display mode. It is fully compatible with laptops and desktops, and supports multiple operating systems including Windows 2000, XP, Vista, Windows 7, Windows 8, and Windows 10.
Customizable Automated Operation
Supports users in editing device operation modes based on actual testing requirements, realizing full automation of measurement steps. The software provides dozens of configurable instructions, allowing users to flexibly combine and save instructions according to specific test procedures—simplifying complex operations into one-click execution.
Fully Enclosed Protective Structure
Adopts a fully enclosed support structure design, which prevents foreign objects from falling into the furnace body, avoids furnace contamination, and reduces maintenance frequency.
Parameters:
Temperature range
0℃~500℃
Temperature resolution
0.01℃
Heating rate
0.1~40℃/min
Cooling rate
0.1~20℃/min
Calorimetric resolution
100%.
Constant temperature
5℃~500℃
Duration of constant temperature
The duration is recommended to be less than 24 hours.
Temperature control mode
Heating, cooling, constant temperature
DSC range
0~±500mW
DSC resolution
0.01mW
DSC sensitivity
0.01mW
Working power
AC 220V 50Hz 300W or other
Atmosphere control gas
Two-channel gas control by automatic controlled (e.g. nitrogen and oxygen)
Gas flow
0-200mL/min
Gas pressure
0.2MPa
Gas flow accuracy
0.2mL/min
Crucible
Aluminium crucible Φ6.6*3mm (Diameter * High)
Calibration standard
with standard material (indium, tin, zinc)
Data interface
Standard USB interface
Display mode
7-inch touch screen
Output mode
computer and printer
Configuration list:
DSC machine
1 set
Aluminium crucibles
300 pieces
Power cords and USB cable
Each one
CD (contains software and operations video)
One
Soft-key
One
Oxygen airway and nitrogen airway
Each 5m
Operation manual
One
Standard sample(contains Indium, tin, zinc)
Each one
Tweezer and medicine spoon
Each one
Custom pressure reducing valve joint and quick joint
Two
Fused glass fuses
Four
External circulation thermostat sink
One
Water pipe
One
Furnace bracket:
Software screenshots:
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter
Employee Number:
50~60
Ecer Certification:
Verified Supplier
Beijing Tonghe Testing Instruments Co., Ltd. Profile
1. Company Foundation and Positioning:
Beijing Tonghe Testing Instrument Co., Ltd. was founded by a core team with over 20 years of experience in material testing and testing machine R&D. With mature technical solutions and a global... Beijing Tonghe Testing Instruments Co., Ltd. Profile
1. Company Foundation and Positioning:
Beijing Tonghe Testing Instrument Co., Ltd. was founded by a core team with over 20 years of experience in material testing and testing machine R&D. With mature technical solutions and a global...