China factories

Chat Now Send Email
China factory - Hunan Yintu New Materials Co., Ltd.

Hunan Yintu New Materials Co., Ltd.

  • China,Changsha ,Hunan
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Air Cooled Commercial Energy Storage Cabinets 50 KW 115.2 KWh IP54 Level
China Air Cooled Commercial Energy Storage Cabinets 50 KW 115.2 KWh IP54 Level

  1. China Air Cooled Commercial Energy Storage Cabinets 50 KW 115.2 KWh IP54 Level
  2. China Air Cooled Commercial Energy Storage Cabinets 50 KW 115.2 KWh IP54 Level
  3. China Air Cooled Commercial Energy Storage Cabinets 50 KW 115.2 KWh IP54 Level

Air Cooled Commercial Energy Storage Cabinets 50 KW 115.2 KWh IP54 Level

  1. MOQ: 1 unit
  2. Price: Quotation on request
  3. Get Latest Price
Rated DC Current 65 A
Cooling Smart air conditioner and fan
Weight 1450 kg
Solution Provider YINTU
Payment Terms T/T
Rated Battery Energy 115.2 kWh
Operating Temperature −20°C to +50°C; >45°C derating
Rated AC Current 73 A
Nominal DC Voltage 768 Vdc
Rated AC Voltage 380 V, 3L/N/PE
Communication RS485 / Ethernet / 4G
Dimensions W × D × H 1150 × 1100 × 2050 mm
Supply Ability 5 units
Battery Chemistry LFP
DC Voltage Range 672–864 Vdc
Protection Level IP54
Maximum DC Current 75 A
Frequency 50 / 60 Hz
Rated AC Power 50 kW
Integrated Systems Battery / converter / BMS / EMS / STS
Delivery Time Confirmed in the project quotation
Packaging Details Wooden Box
Cell Capacity 150 Ah
Equipment Series YOTAI Ener Hexon Solution115
Model Number YT-DS5T0115-P0050A
Brand Name YOTAI
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Rated DC Current 65 A Cooling Smart air conditioner and fan
Weight 1450 kg Solution Provider YINTU
Payment Terms T/T Rated Battery Energy 115.2 kWh
Operating Temperature −20°C to +50°C; >45°C derating Rated AC Current 73 A
Nominal DC Voltage 768 Vdc Rated AC Voltage 380 V, 3L/N/PE
Communication RS485 / Ethernet / 4G Dimensions W × D × H 1150 × 1100 × 2050 mm
Supply Ability 5 units Battery Chemistry LFP
DC Voltage Range 672–864 Vdc Protection Level IP54
Maximum DC Current 75 A Frequency 50 / 60 Hz
Rated AC Power 50 kW Integrated Systems Battery / converter / BMS / EMS / STS
Delivery Time Confirmed in the project quotation Packaging Details Wooden Box
Cell Capacity 150 Ah Equipment Series YOTAI Ener Hexon Solution115
Model Number YT-DS5T0115-P0050A Brand Name YOTAI
Place of Origin China
High Light 115.2 KWh Commercial Energy Storage Cabinets ,Air Cooled Commercial Energy Storage Cabinets ,IP54 Intelligent Commercial ESS

COMMERCIAL & INDUSTRIAL ENERGY STORAGE SOLUTIONS

50 kW / 115.2 kWh Air-Cooled Commercial Energy Storage Cabinet

Ener Hexon Solution115 is a 50 kW / 115.2 kWh integrated air-cooled energy storage cabinet for commercial and smaller industrial sites. It combines the battery and conversion equipment needed to manage selected site loads, shift solar energy and develop a project-specific backup arrangement.

Equipment Overview

The manufacturer describes ten air-cooled battery packs, a 50 kW ESS converter, on/off-grid switching (STS), BMS, EMS, temperature control and fire protection. The LFP battery operates at 768 V nominal. The cabinet measures 1150 × 1100 × 2050 mm (W × D × H) and weighs 1450 kg.

YINTU is an energy storage solution provider. We match project requirements with products from capable manufacturing partners, including YOTAI, and coordinate equipment selection, technical clarification and supply. The equipment described here is YOTAI's Ener Hexon series; YINTU's project scope is agreed in the quotation.

YT-DS5T0115-P0050A application concept
Illustrative application concept. Equipment and site layout depend on the project.

Commercial & Industrial Application Scenarios

Small factories and workshops

Schedule charge and discharge around production shifts and demand peaks. A 50 kW converter can serve a selected portion of the site demand; motors, compressors and welding equipment need starting-current and load-quality checks before sizing.

Retail, offices and commercial premises

Shift energy between selected tariff periods and maintain a reserve for essential circuits such as lighting, communications and access systems. Use the actual demand profile to balance daily energy management against backup readiness.

Warehouses and cold-chain support

Assess storage for selected refrigeration, controls and logistics loads where brief interruptions or demand peaks create operational concerns. Compressor starting currents, required ride-through and temperature-control procedures must be evaluated; do not assume the whole facility can be backed up by one cabinet.

Rooftop solar self-consumption

Connect through the site's AC network with a compatible external PV inverter. Store selected surplus generation for evening activity or later production shifts, with EMS settings designed around export limits and the site's load pattern.

Remote branches and small microgrids

The datasheet specifies both grid-connected and off-grid AC operation. Evaluate essential-load supply at smaller remote facilities, mines or village service buildings with an agreed switching and protection design. Generator coordination, where needed, must be verified separately.

System Features and Project Value

Integrated cabinet

Battery packs, converter, BMS, EMS and STS reduce the number of separately selected storage subsystems while leaving site installation and protection to the project design.

Air-based temperature control

Smart air conditioning and fans manage cabinet temperature. Provide service access and suitable airflow; output derating applies above 45°C.

Expansion planning

The manufacturer describes a 50–300 kW expansion range. Parallel operation, cabinet count and site distribution must follow the supplier-approved architecture.

Monitoring and maintenance

RS485, Ethernet and 4G communication options support project monitoring. Confirm network access, remote service availability and operator permissions in the final scope.

How the System Fits Your Site

This is an AC-coupled solar-storage concept. An external PV inverter supplies the site AC bus, while the cabinet's integrated converter charges or discharges the battery. STS is identified in the manufacturer description, but transfer time is not specified. Backup design must define grid isolation, essential-load circuits, protection and the intended operating sequence.

YT-DS5T0115-P0050A conceptual system topology
Concept diagram only. Follow the approved single-line diagram and installation documents.

Technical Specifications

Battery / DC

Parameter Specification
Manufacturer model YT-DS5T0115-P0050A
Rated energy / capacity 115.2 kWh / 150 Ah
Cell specification LFP, 3.2 V / 150 Ah
Nominal DC voltage 768 Vdc
DC voltage range 672–864 Vdc
Charge/discharge rate ≤0.5 CP, as stated
Rated / maximum DC current 65 A / 75 A

AC performance

Parameter Specification
Grid-connected rated power / current 50 kW / 73 A
Grid voltage 3L/N/PE, 380 V ±10%
Grid frequency 50 / 60 Hz
THDi <3% at rated power
Power factor >0.99 at rated power; adjustable −1 (leading) to 1 (lagging)
Maximum conversion efficiency 98.8% listed under AC converter parameters; not system round-trip efficiency
Off-grid rated power 50 kW
Off-grid voltage / frequency 3L/N/PE, 380 V ±5%; 50 / 60 Hz
Off-grid THDv <3% with linear load

Cabinet and site conditions

Parameter Specification
Dimensions (W × D × H) 1150 × 1100 × 2050 mm
Weight 1450 kg
Cooling Smart air conditioner and smart fan
Protection level IP54
Operating temperature −20°C to +50°C; derating above 45°C
Storage temperature −20°C to +45°C; SOC 30–50%; less than 6 months
Humidity 5–95% RH, non-condensing
Altitude Up to 3000 m; derating above 2000 m
Communication RS485 / Ethernet / 4G

Documentation

Parameter Specification
Battery standards listed IEC 62619; IEC 61000; UN 38.3
Inverter standards listed GB/T 34133-2017; GB/T 34120-2017; IEC 61000; IEC 62477
Source version Ener Hexon Solution115, V1.12
Compliance scope Confirm model-specific reports and destination requirements before ordering

From Site Requirements to a Storage Solution

1. Define the operating objective

Identify whether the priority is peak management, solar self-consumption, backup or microgrid operation. Use the actual load profile and generation resources to set the power, energy and operating reserve.

2. Match equipment and interfaces

YINTU coordinates equipment selection and technical clarification with the manufacturing partner, including voltage, controls, environment, expansion and optional functions.

3. Confirm delivery and service scope

Agree the final equipment list, metering, protection, switchgear, transformer (if required), cables, foundations, installation, commissioning and service responsibilities before ordering. PV modules, generators, wind turbines, EV chargers and site works are included only when listed in the quotation. Warranty, lead time, MOQ and price are confirmed for the selected configuration.

Frequently Asked Questions

Does Solution115 include an inverter or PCS?

The manufacturer describes an integrated 50 kW ESS converter together with BMS, EMS and STS. The project quotation should confirm the complete offered configuration and site-side equipment.

Can it connect directly to PV strings?

The supplied datasheet does not specify a direct PV MPPT interface. The illustrated solar application uses an external PV inverter on the AC side.

Does STS mean zero interruption?

No transfer-time value is supplied in this datasheet. Confirm the actual switching performance against the needs of each essential load; equipment requiring uninterrupted supply may need a dedicated UPS.

How is backup duration selected?

The nominal energy-to-power ratio is 115.2 / 50, or about 2.30 hours. This is not usable AC runtime. Confirm the usable SOC window, load variations, losses and temperature before setting a backup target.

Discuss Your C&I Energy Storage Project

Send the project country, AC voltage and frequency, interval load data, tariff schedule, existing PV and generator details, required backup loads and duration, site plan, ambient conditions and target delivery date. YINTU will coordinate a suitable configuration, equipment interfaces, documentation and quotation with the manufacturing partner.

Figures are taken from the supplied manufacturer datasheet and are subject to the final order specification. Rated battery energy is not guaranteed usable AC energy. Runtime depends on the usable SOC window, load, temperature, conversion losses and auxiliary consumption. Application images are illustrative concepts, not photographs of completed YINTU projects. Topology drawings show operating concepts and are not installation wiring diagrams.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Distributor/Wholesaler,Exporter,Trading Company

  • Year Established:

    2016

  • Total Annual:

    $ 10 million-$ 20,million

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

Your Partner for Energy Storage Product Sourcing YINTU Energy is the energy storage business of Hunan Yintu New Materials Co., Ltd. Established in 2016, our company has 10-50 employees and an export share of 100%. We connect overseas distributors, installers, EPC companies and project buyers with... Your Partner for Energy Storage Product Sourcing YINTU Energy is the energy storage business of Hunan Yintu New Materials Co., Ltd. Established in 2016, our company has 10-50 employees and an export share of 100%. We connect overseas distributors, installers, EPC companies and project buyers with...

+ Read More

Get in touch with us

  • Reach Us
  • Hunan Yintu New Materials Co., Ltd.
  • 201, Building B6, Xinggongchang Industrial Park, No.1 Lantian North Road, Economic Development Zone, Changsha, Hunan, China
  • https://www.yintuenergy.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement