| Maximum AC Current | 45 A (30 kW) / 75 A (50 kW) |
| MPPT Channels | 2 |
| Communication | RS485/WiFi |
| Dimensions (Source Order) | 665 × 950 × 2,100 mm |
| Rated Battery Energy | 65 kWh |
| Battery Cooling | Air conditioner |
| MPPT Voltage Range | 200-800 V DC |
| AC Connection | L1/L2/L3/N/PE |
| Maximum PV Voltage | 850 V DC |
| Cabinet Protection | IP54 |
| Generator Interface | Yes |
| Rated AC Power | 30 or 50 kW |
| Rated Frequency | 50/60 Hz |
| Switching Time | <10 ms |
| Maximum PV Power | 38 kW |
| Maximum PV Input Current | 30 A + 30 A |
| Battery Chemistry | LiFePO4 |
| Operating Temperature | -10 to +50 C |
| Delivery Time | Confirmed in the project quotation |
| Packaging Details | Transport packaging and handling requirements to be confirmed for the project. |
| AC Voltage | 400/230 V AC, three phase |
| Approximate Weight | Approx. 1,000 kg (30 kW) / 1,050 kg (50 kW) |
| Model Number | YT-Hybrid ESS-30/50kW-65kWh |
| Brand Name | YINTU |
View Detail Information
Explore similar products
Integrated Commercial & Industrial Energy Storage IP65 Protection 250 KW Hybrid
150.5 KWh Commercial And Industrial Energy Storage Smart Temp Control Fire
52 KWh / 25 KW Hybrid ESS Energy Storage Cabinets IP54 For Commercial Industrial
Customized Industrial Commercial Energy Storage Cabinets 125 KW 261 KWh Liquid
Product Specification
| Maximum AC Current | 45 A (30 kW) / 75 A (50 kW) | MPPT Channels | 2 |
| Communication | RS485/WiFi | Dimensions (Source Order) | 665 × 950 × 2,100 mm |
| Rated Battery Energy | 65 kWh | Battery Cooling | Air conditioner |
| MPPT Voltage Range | 200-800 V DC | AC Connection | L1/L2/L3/N/PE |
| Maximum PV Voltage | 850 V DC | Cabinet Protection | IP54 |
| Generator Interface | Yes | Rated AC Power | 30 or 50 kW |
| Rated Frequency | 50/60 Hz | Switching Time | <10 ms |
| Maximum PV Power | 38 kW | Maximum PV Input Current | 30 A + 30 A |
| Battery Chemistry | LiFePO4 | Operating Temperature | -10 to +50 C |
| Delivery Time | Confirmed in the project quotation | Packaging Details | Transport packaging and handling requirements to be confirmed for the project. |
| AC Voltage | 400/230 V AC, three phase | Approximate Weight | Approx. 1,000 kg (30 kW) / 1,050 kg (50 kW) |
| Model Number | YT-Hybrid ESS-30/50kW-65kWh | Brand Name | YINTU |
| High Light | 65 kWh Hybrid Commercial Battery ESS ,Remote Monitoring Commercial and Industrial ESS ,PCS Cooling Commercial Industrial Energy Storage | ||
COMMERCIAL & INDUSTRIAL ENERGY STORAGE SOLUTIONS
One 65 kWh battery capacity with two alternative power configurations for small commercial sites and large residential estates. The system combines a LiFePO4 battery, PCS, BMS, EMS, two MPPT channels and a diesel generator interface. It supports grid-connected and off-grid applications at 400/230 V AC, 50/60 Hz.
The cabinet integrates 65 kWh rated battery energy, 30 or 50 kW rated AC power, up to 38 kW PV input, battery air conditioning, intelligent PCS cooling and integrated fire protection. External PV modules, generator equipment, distribution, protection and installation works are defined separately in the project scope.
YINTU is an energy storage solution provider. We combine project requirements with products from capable manufacturing partners, coordinating equipment selection, system interfaces and technical documentation for the customer and local installation team.
Coordinate solar and storage for a main residence, guesthouse and selected estate services on a suitable three-phase network. Define essential circuits and backup reserve before adding discretionary loads such as pool heating or vehicle charging.
Shift available solar energy toward evening service and protect selected operational loads. Compare the 30 kW and 50 kW options against kitchen equipment, refrigeration and cooling demand; the battery energy remains 65 kWh in either case.
The 50 kW option offers a higher rated power than the 30 kW option at the same nominal battery capacity. Check motor starting and overload requirements separately; a larger power rating does not create additional stored energy.
Coordinate pumps and scheduled estate activities with solar availability. A site energy plan can reserve battery capacity for evening living areas while managing flexible daytime loads within the selected configuration.
Combine PV, storage and the generator interface in a project-specific microgrid. Confirm generator compatibility, isolation, minimum operating conditions and control logic before promising autonomous operation.
Two MPPT channels support a specified maximum PV input of 38 kW. PV string design must respect the 850 V DC maximum voltage, 200–800 V DC MPPT range and 30 A + 30 A maximum input current; PV nameplate power is not battery discharge power.
Both options use a 65 kWh battery and a 38 kW maximum PV input. The 30 kW option has a 45 A maximum AC current and weighs approximately 1,000 kg; the 50 kW option has a 75 A maximum AC current and weighs approximately 1,050 kg. They are alternative configurations, not a combined 80 kW system.
The 65 kWh rating describes nominal battery energy. Usable AC energy and runtime depend on discharge limits, conversion losses, auxiliary consumption, temperature and the reserve policy. Load measurements are required for a meaningful backup estimate.
The specified connection is L1/L2/L3/N/PE at 400/230 V AC. Grid-connected and off-grid rated powers are the same for each configuration. Confirm phase balance, starting loads, local connection rules and protection coordination.
A diesel generator port is specified, with a grid/off-grid switching time below 10 ms. Transfer performance depends on configuration and load requirements; this is not an unconditional no-break guarantee for every appliance or IT load. Generator ratings and control details require confirmation.
IP54 cabinet protection, battery air conditioning, intelligent PCS cooling and integrated fire protection support the equipment design. RS485/WiFi communication is specified. Installation location, drainage, foundation, clearance and access must follow the approved project documents.
PV connects to the integrated MPPT inputs. The 65 kWh battery and PCS manage energy within the cabinet, while the AC connection serves selected three-phase business or estate loads. Grid and diesel generator interfaces must use the approved isolation, protection and control arrangement. The diagram is a functional overview, not installation wiring or permission to parallel sources. Export, zero-export and generator operating modes must be confirmed for the project.
| Parameter | 30 kW option | 50 kW option |
| Battery chemistry | LiFePO4 | LiFePO4 |
| Rated battery energy | 65 kWh | 65 kWh |
| Rated AC power (grid/off-grid) | 30 kW | 50 kW |
| Maximum AC current (grid/off-grid) | 45 A | 75 A |
| Maximum PV power | 38 kW | 38 kW |
| Approximate weight | 1,000 kg | 1,050 kg |
| Source configuration reference | IYP-B65-30H3-38M2-HX1 | IYP-B65-50H3-38M2-HX1 |
| Parameter | Specification |
|---|---|
| Maximum PV power | 38 kW |
| Maximum PV voltage | 850 V DC |
| MPPT voltage range | 200–800 V DC |
| Maximum PV input current | 30 A + 30 A |
| MPPT channels | 2 |
| Parameter | Specification |
|---|---|
| AC voltage / connection | 400 / 230 V AC; L1/L2/L3/N/PE |
| Rated frequency | 50 / 60 Hz |
| Grid / off-grid switching time | <10 ms |
| Maximum parallel units | 3 (listed in off-grid section; subject to approved system design) |
| Diesel generator port | Yes |
| Communication | RS485 / WiFi |
| Parameter | Specification |
|---|---|
| Cabinet ingress protection | IP54 |
| Fire protection system | Integrated |
| Operating temperature | −10 to +50°C |
| Relative humidity | 5–95% |
| Altitude | <3,000 m |
| Battery cooling | Air conditioner |
| PCS cooling | Intelligent cooling |
| Dimensions (source order) | 665 × 950 × 2,100 mm |
| Weight | Approx. 1,000 kg (30 kW) / 1,050 kg (50 kW) |
Identify whether the priority is peak management, solar self-consumption, backup or microgrid operation. Use the actual load profile and generation resources to set the power, energy and operating reserve.
YINTU coordinates equipment selection and technical clarification with the manufacturing partner, including voltage, controls, environment, expansion and optional functions.
Confirm the cabinet configuration, PV string design, grid requirements, generator controls, protection, earthing, installation clearances and commissioning responsibilities before ordering. YINTU coordinates the technical scope with the manufacturing partner; local qualified professionals complete the approved installation. Warranty, certification documents, lead time and after-sales arrangements are confirmed in the project quotation.
Compare the 30 kW and 50 kW options with simultaneous demand and the supplier-confirmed starting-load capability. Both have the same nominal stored energy and maximum PV input. Choose the power option through load assessment, not simply by battery capacity.
It can be considered for a property with a suitable three-phase electrical system and a professionally designed installation. A site survey must confirm voltage, phase balance, peak demand, motor starting and backup circuits. It is not a plug-in appliance for an ordinary single-phase household.
The nominal 65 kWh battery rating does not define a fixed runtime. Share the critical-load profile and required reserve so the usable energy, losses and operating limits can be assessed. Entire-site backup must not be assumed.
Possibly, after checking the PV electrical design and existing inverter architecture, as well as generator interface and control compatibility. The built-in PV input and generator port do not remove the need for a site-specific integration design.
The datasheet lists a maximum of three parallel units in the off-grid section. Confirm the approved configuration, controls and protection with the supplier; parallel capability in every operating mode is not implied.
YINTU provides energy storage solutions using products from manufacturing partners. We help clarify requirements, select the appropriate equipment and coordinate technical and delivery arrangements. Project certification, warranty and service scope are confirmed before ordering.
Share your location, three-phase supply details, daily load profile, maximum demand, PV capacity, generator information and preferred backup loads. For estates, include the main residence, guesthouses, pumps, cooling and EV charging schedules. YINTU will help match battery capacity and power configuration to the operating plan.
Specifications are transcribed from the supplied YINTU datasheet, version 1.0 (2026.10). Dimensions follow the source order. Images are illustrative and configuration may vary. Final equipment, interfaces and operating limits are subject to the confirmed technical agreement. Nominal battery energy is not usable AC energy or a guaranteed backup duration.
Company Details
Business Type:
Distributor/Wholesaler,Exporter,Trading Company
Year Established:
2016
Total Annual:
$ 10 million-$ 20,million
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Your Partner for Energy Storage Product Sourcing YINTU Energy is the energy storage business of Hunan Yintu New Materials Co., Ltd. Established in 2016, our company has 10-50 employees and an export share of 100%. We connect overseas distributors, installers, EPC companies and project buyers with... Your Partner for Energy Storage Product Sourcing YINTU Energy is the energy storage business of Hunan Yintu New Materials Co., Ltd. Established in 2016, our company has 10-50 employees and an export share of 100%. We connect overseas distributors, installers, EPC companies and project buyers with...
Get in touch with us
Leave a Message, we will call you back quickly!