| Packaging Details | original packing |
| Motor Control | Open Loop Vector, V/f and PM Open Loop Vector |
| Enclosure Rating | IP20 / NEMA 1 |
| Delivery Time | 3-5Days |
| Input Power | 380-480 VAC, Three-Phase |
| Braking Transistor | Built In |
| Supply Ability | 20Units per Month |
| Normal Duty Power | 10 HP |
| Heavy Duty Output Current | 14.8 A |
| Payment Terms | D/A, D/P, T/T, Western Union, MoneyGram, |
| Heavy Duty Power | 7.5-10 HP |
| Model | CIMR-VU4A0018FAA |
| Normal Duty Output Current | 17.5 A |
| Model Number | CIMR-VU4A0018FAA |
| Brand Name | YASKAWA |
| Place of Origin | USA |
View Detail Information
Explore similar products
Yaskawa CIMR-VU4A0023FAA V1000 VFD 480V 3-Phase 15HP 23A NEMA 1
Yaskawa CIMR-VU4A0031FAA V1000 VFD 480V 3-Phase 20HP 31A NEMA 1
Yaskawa CIMR-VU4A0004FAA V1000 VFD 480V 3-Phase 2HP 4.1A NEMA 1
Yaskawa CIMR-VU4A0007FAA V1000 VFD 480V 3-Phase 4HP 6.9A NEMA 1
Product Specification
| Packaging Details | original packing | Motor Control | Open Loop Vector, V/f and PM Open Loop Vector |
| Enclosure Rating | IP20 / NEMA 1 | Delivery Time | 3-5Days |
| Input Power | 380-480 VAC, Three-Phase | Braking Transistor | Built In |
| Supply Ability | 20Units per Month | Normal Duty Power | 10 HP |
| Heavy Duty Output Current | 14.8 A | Payment Terms | D/A, D/P, T/T, Western Union, MoneyGram, |
| Heavy Duty Power | 7.5-10 HP | Model | CIMR-VU4A0018FAA |
| Normal Duty Output Current | 17.5 A | Model Number | CIMR-VU4A0018FAA |
| Brand Name | YASKAWA | Place of Origin | USA |
The Yaskawa CIMR-VU4A0018FAA is a V1000 compact current-vector variable frequency drive designed for 380-480 VAC three-phase power systems. It provides a Normal Duty rating of 10 HP at 17.5 A and a Heavy Duty rating of 7.5 to 10 HP at 14.8 A, depending on the applicable motor characteristics and operating conditions. Output current remains the principal limit when determining whether the drive is suitable for a specific motor.
The model is widely applicable to pumps, fans, conveyors, mixers, packaging machines and general industrial equipment. Its multiple control modes support conventional induction-motor applications as well as appropriately configured permanent-magnet motors. Programmable terminals and serial communication allow integration into standalone machines or PLC-based automation systems.
| Manufacturer | Yaskawa |
| Complete Model | CIMR-VU4A0018FAA |
| Series | V1000 |
| Product Type | Compact Current Vector VFD |
| Input Voltage | 380-480 VAC, Three-Phase |
| Normal Duty Rating | 10 HP, 17.5 A |
| Heavy Duty Rating | 7.5 to 10 HP, 14.8 A |
| Motor Control | Open Loop Current Vector, V/f, PM Open Loop Vector |
| Overload Capacity | ND 120% for 60 s; HD 150% for 60 s |
| Communication | RS-422/485 MEMOBUS/Modbus |
| Protective Design | IP20 / NEMA 1 |
| Braking Transistor | Standard Built-in |
The CIMR-VU4A0018FAA can operate compatible induction motors using V/f or Open Loop Current Vector control. PM Open Loop Vector control is also available, but permanent-magnet motor commissioning requires accurate motor data and appropriate parameter settings. The drive should not be connected to an unknown PM motor without confirming its voltage, current, pole count and back-EMF characteristics.
Normal Duty is generally suitable for centrifugal pumps, fans and moderate-overload systems. Heavy Duty should be evaluated for loaded conveyors, mixers and machinery with frequent torque changes. For continuous low-speed operation, confirm that the motor has sufficient cooling. For frequent stopping, calculate the braking resistor duty and regenerative energy.
Verify the complete nameplate model before replacing this drive. Record the existing parameters, terminal assignments, control mode, motor data, communication address and fault history. Confirm whether the application uses an external braking resistor, safety circuit, analog current reference or optional communication hardware.
If the previous drive failed, inspect the motor winding, output cable, grounding and mechanical load before energizing the replacement. A shorted motor cable, seized mechanism or insulation fault can damage a replacement drive immediately. Verify cabinet ventilation and clear accumulated dust from the cooling path.
For migration to GA500, select the replacement from output current and operating duty rather than the 10 HP designation alone. Parameter conversion can assist commissioning, but all safety-related functions, I/O logic, network communication and rating-dependent parameters must be reviewed and tested.
Related V1000 models include CIMR-VU4A0011FAA, CIMR-VU4A0023FAA and CIMR-VU4A0031FAA. CIMR-VU4A0011FAA is suitable for lower current requirements, while CIMR-VU4A0023FAA provides additional continuous and overload capacity.
Please provide the complete drive and motor nameplates, operating duty, application type, required quantity and any installed braking or communication options. Final compatibility should be confirmed against the installed machine before ordering.
Company Details
Business Type:
Exporter,Trading Company,Seller
Year Established:
2024
Total Annual:
1000000-1500000
Employee Number:
10~25
Ecer Certification:
Site Member
Company Profile DF Automatic supplies industrial automation spare parts, control system components, and replacement parts to customers worldwide. Our product range covers PLC modules, servo drives, servo motors, variable frequency drives, HMI panels, industrial sensors, pneumatic components, h... Company Profile DF Automatic supplies industrial automation spare parts, control system components, and replacement parts to customers worldwide. Our product range covers PLC modules, servo drives, servo motors, variable frequency drives, HMI panels, industrial sensors, pneumatic components, h...
Get in touch with us