| Delivery Time | 10-15 working days |
| Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
| Spraying Time | ≤10s |
| Environmental | Environmentally Friendly |
| Supply Ability | 300 sets per month |
| Power | DC24V/1.6A |
| Durability | High Durability |
| System Components | Control Panel, Cylinders, Piping, Nozzles, Detectors |
| Packaging Details | Plywood outer box with bubble bag or paper |
| Model Number | QQP4/6 QQP7.5/6 QQP10/6 QQP20/6 DQP40/6 |
| Place of Origin | China |
| Certification | CAL,CMA,CNAS,ILAC-MRA,CCC |
| Brand Name | Xingjin |
View Detail Information
Explore similar products
Argonite Fire Suppression System Ig55
30MPa IG541 Inergen Gas Fire Suppression System For Minimal Damage
IG55 Argonite Fire System
15MPa 80L 90L Inergen Gas Fire Suppression System Reasonable Good Price High
Product Specification
| Delivery Time | 10-15 working days | Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
| Spraying Time | ≤10s | Environmental | Environmentally Friendly |
| Supply Ability | 300 sets per month | Power | DC24V/1.6A |
| Durability | High Durability | System Components | Control Panel, Cylinders, Piping, Nozzles, Detectors |
| Packaging Details | Plywood outer box with bubble bag or paper | Model Number | QQP4/6 QQP7.5/6 QQP10/6 QQP20/6 DQP40/6 |
| Place of Origin | China | Certification | CAL,CMA,CNAS,ILAC-MRA,CCC |
| Brand Name | Xingjin | ||
| High Light | 6.0MPa Drive Cylinder ,High-Purity Nitrogen Drive Cylinder ,Dual Actuation Drive Cylinder | ||
The Driving Gas Cylinder is a critical actuation component in gas fire suppression systems, enabling automatic, manual, and mechanical emergency start operations. By storing high-pressure nitrogen, it quickly and reliably opens selector valves and agent container valves when a fire occurs, ensuring the extinguishing agent reaches the protected area in the shortest possible time.
| Parameter | Specification |
|---|---|
| Cylinder Volume | 4L / 10L (customizable) |
| Charging Pressure (20℃) | 6.0 MPa |
| Driving Medium | High-purity Nitrogen (moisture ≤15mL/m³) |
| Operating Voltage | DC 24V ± 3V, 1.5A |
| Solenoid Force | 55N ~ 90N |
| Connection Thread | M14×1.5 (flare) |
| Operating Temperature | 0℃ ~ +50℃ |
| Standard | GB 25972-2010 Gas Fire Extinguishing Systems and Components |
| Compatible Systems | FM200, IG541, IG100, IG55, High-Pressure CO₂, External Storage HFC-227ea, Novec1230 |
Safe and Reliable: Manufactured with high-quality seamless steel cylinders, each unit undergoes rigorous pressure and leakage testing to ensure normal operation at -18℃~+50℃. Key components are FM/UL certified.
Dual Actuation Assurance: Supports both electrical automatic start (DC 24V solenoid valve) and mechanical emergency manual start (manual push button), ensuring operation under any circumstances.
Multi-Level Safety Protection:
Solenoid Driver Safety Pin: Prevents accidental discharge during transportation and installation
Low Leakage High Seal Valve: Automatically vents minor pipeline leaks to prevent system mis-actuation
Real-time Pressure Gauge: Enables easy daily inspection and monitoring
Standardized Interface: M14×1.5 flare thread connections compatible with mainstream actuation piping systems for easy installation.
Low Maintenance: Cylinders are refillable with long service life; solenoid actuators are removable for inspection, reducing maintenance costs.
| Component Name | Parameter Description |
|---|---|
| Electromagnetic Actuator | Model MFZ1 series, DC 24V power supply, rated current 1.5A, rated suction force 55N-90N (depending on specific model) |
| Pneumatic Actuator | Model QQQ1.2MPa / DYQQ1.2MPa / HQQ1.2MPa, nominal pressure 6.6MPa, minimum actuation pressure 1.2MPa |
| Low-Pressure Relief & Check Valve | Model EDGO.3/6.6, closing pressure 0.3±0.03MPa, used to prevent false actuation due to minor leakage in the pilot line |
| Pneumatic Check Valve | Model EQD6/6.6, nominal diameter 6mm, opening pressure 0.2MPa, connection thread M14×1.5 |
| Pilot Line | φ8×1 copper tube, ferrule-type tube fittings connection, bracket spacing ≤0.6m |
| Safety Relief Device | Configured according to the driving cylinder bank pressure to prevent overpressure |
Hanging Type Fire Suppression Units – Space-saving ceiling-mounted designs
Inert Gas Fire Suppression Systems – IG55, IG100, IG541
CO2 Fire Suppression Systems
Fire Detection Tubes – Flexible heat-sensing tubes for cabinet protection
NOVEC 1230 Systems – Fluoroketone-based clean agent
Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional manufacturer specializing in automatic clean agent fire suppression systems. With over 10 years of industry experience and SGS/BV certification, we offer:
Factory-direct pricing with 5-year quality guarantee
Customized solutions (OEM/ODM available)
Professional technical support and installation guidance
Global export experience to Middle East, Southeast Asia, Africa, and beyond
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2010
Total Annual:
600000-1200000
Employee Number:
100~300
Ecer Certification:
Verified Supplier
About Us: Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro... About Us: Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro...
Get in touch with us
Leave a Message, we will call you back quickly!