| Supply Ability | 300 sets per month |
| Packaging Details | Plywood outer box with bubble bag or paper |
| Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
| Delivery Time | 10-15 working days |
| Brand Name | Xingjin |
| Place of Origin | China |
| Certification | CAL,CMA,CNAS,ILAC-MRA,CCC |
| Model Number | QMH15/80, QMH15/90 |
View Detail Information
Explore similar products
140L Cylinder Volume 30MPa Working Pressure Automatic Start Inert Gas Fire
80L Cylinder Volume 30MPa Working Pressure Enclosed Flooding Argonite Fire
30MPa 80L IG541 Inergen Gas Fire Suppression System for Minimal Damage
80L Cylinder Volume Enclosed Flooding IG55 Argonite Fire System with 30MPa
Product Specification
| Supply Ability | 300 sets per month | Packaging Details | Plywood outer box with bubble bag or paper |
| Payment Terms | L/C,D/A,D/P,T/T,Western Union,MoneyGram | Delivery Time | 10-15 working days |
| Brand Name | Xingjin | Place of Origin | China |
| Certification | CAL,CMA,CNAS,ILAC-MRA,CCC | Model Number | QMH15/80, QMH15/90 |
| High Light | IG100 Gas Fire Suppression System ,IG100 Inert Gas Fire Suppression System | ||
IG100 uses 100% pressurized nitrogen — which makes up 78% of the atmosphere — as the extinguishing agent. Its ozone depletion potential (ODP) and global warming potential (GWP) are both zero, and its atmospheric retention time is zero, with no adverse effects on the environment. The system fully integrates the design concept of the modern fire-extinguishing system, giving the product both environmental protection and efficient fire-fighting performance.
IG100 characteristics: protects the ecological environment, is safe and hygienic, does not interfere with vision, leaves no stains from the extinguishing agent, and delivers a durable fire-fighting effect. Nitrogen can be separated from the air and produced from a wide range of sources at low cost.
Combined with the extinguishing device and electronic accessories, the whole system can be actuated automatically. It monitors the situation of the protected region through detectors and can then start the extinguishing device through a solenoid actuator automatically, achieving full automation. This avoids the risk of a fire going unnoticed when no one is present, and it also saves the cost of employing personnel to supervise the protected area.
Management of multiple zones is also under the safe control of the whole system. One system can protect multiple zones through distributing valves, allowing the system to alternate between different protected zones. Agent is discharged only into the zone where the fire occurs, making fire suppression highly efficient in a short time. Note that a small room should be reserved as storage space for the whole system.
Structure: The IG541 mixed gas fire extinguishing cylinder group consists of the fire extinguishing agent and storage containers, container valves, safety relief devices, pressure gauges, and related components.
| Specifications and Models Project | QMH15/80 | QMH15/90 |
|---|---|---|
| Design pressure (MPa) | 17.2 | |
| Working pressure (MPa) | 15 | |
| Ambient temperature (℃) | 0~50 | |
| Fire extinguisher volume V (L) | 80 | 90 |
| Outer diameter D (mm) of the fire extinguisher canister | Φ279 | Φ325 |
| Fire extinguisher height H (mm) | 1578+73 | 1345+60 |
| Mixed gas filling volume (m³) | 12 | 13.5 |
| Container valve nominal diameter (mm) | 15 | |
| Container valve outlet thread | M30×1.5 | |
| Safety relief pressure (MPa) | 23±1.15 | |
2.1 Structural schematic (see figure below)
2.2 Main performance parameters
| Model | Design Pressure (MPa) | Nominal Diameter (mm) | Connection Thread | Valve Opening Capacity (MPa) |
|---|---|---|---|---|
| HRF15/17.2 | 17.2 | 15 | PZ39 | < 3.0 |
2.3 Purpose
The container valve is installed on the fire extinguishing agent storage cylinder to seal the extinguishing agent inside. During a fire, the valve is typically opened by actuating gas to release the extinguishing agent for fire suppression.
2.4 Usage and Maintenance Instructions
3.1 Purpose
The gas actuator is mounted on the container to activate its valve. During a fire, the controller issues a fire suppression command, activating the gas cylinder bank corresponding to the selection valve. This bank releases the activation gas, which opens the respective selection valve. The activation gas then flows through a gas check valve into the actuator pipeline, driving the internal blade to puncture the working diaphragm in the container valve, thereby opening the valve. The valve subsequently releases the fire extinguishing agent to suppress the fire.
During manual activation, remove the safety pin, press the manual handle to puncture the working diaphragm in the container valve, open the valve, and release the fire extinguishing agent to extinguish the fire.
Model, structural diagram and main performance parameters:
| Air Actuator Model | Container Valve Connection Thread | Drive Pipeline Thread | Nominal Power | Minimum Starting Force |
|---|---|---|---|---|
| HQQ1.2MPa | M16*1.5 | M14*1.5 flanged | 6.6MPa | 1.2MPa |
Structure: Consists of an air cylinder and an electromagnetic starting valve.
Working Principle: The gas cylinder is a steel pressure vessel filled with high-pressure nitrogen. In the event of a fire alarm, the fire alarm controller outputs a DC-24V current, which activates the electromagnet to open the starting valve, releasing the nitrogen from the cylinder. The released nitrogen then flows through the drive pipeline, opening the container valve. During emergencies, the manual button safety pin can also be removed, allowing immediate activation of the starting valve upon button press.
Structure: The manual/electromagnetic valve consists of the main valve body, connection seat, electromagnet, actuator rod, spring, manual button, and manual safety pin.
Working Principle: The manual/electromagnetic valve is installed on the start-up bottle assembly or container valve. When a fire alarm occurs in the protected area, the fire alarm controller outputs a DC 24V current, activating the electromagnet to push the actuator rod and open the container valve or start-up valve. In emergencies, the manual safety pin can be immediately removed, and the button pressed to open the container or start-up valve.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2010
Total Annual:
600000-1200000
Employee Number:
100~300
Ecer Certification:
Verified Supplier
About Us: Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro... About Us: Guangzhou Xingjin Fire Equipment Co., Ltd. is a professional enterprise dedicated to the research, development and production of HFC-227ea (FM200), Novec1230, CO2 and inert gas products. For many years, the company has been committed to improving product quality, enriching pro...
Get in touch with us
Leave a Message, we will call you back quickly!