Products
Manufacturer of a wide range of products which include Large Power Generator Test Equipment Power Frequency Resonant Circuit Test,Large Power Generator Test Equipment Power Frequency Resonant Circuit Test,90KV Very Low Frequency V...
MOQ: One unit
Price: 40000~150000 USD /Unit according to detailed model
| Payment Terms | L/C, T/T |
| Supply Ability | 5units/2months |
| Delivery Time | 35~45 work days |
| Packaging Details | Export standard wooden case with fumigation free |
| Test Principle | Power Frequency Resonant Circuit |
| Usage | AC Hipot Test for large generator stator or rotor winding |
| Max.capacity: | 3750KVA |
| Max. Voltage | 65KV |
| Design Feature: | Adjustable inductance test reactor , 50Hz or 60Hz testing ,Dedicated to large hydroelectric generator stator test |
| Component | Control console,Voltage regulator,Excitation Transformer,Adjustable inductance reactor, Optional load compensation load reactor, And Voltage Divider |
| Test Frequency | 50Hz or 60Hz |
| Duty Cycle | 10mints or made by order |
| Test Accuracy | No Less Than 1.0% |
| Output Waveform | Pure Sine Wave |
| Special For | AC Hipot test for Large hydro-generator stator or thermal generator stator |
| Test Standard: | IEC60060-1:2010 ; IEC 60034-1:2004; IEEE 115:2009; GB/T 8564-2003; JB/T 6204-2002 |
| Note | PD free Type can be made by order |
| Brand Name | Fanke High-voltage |
| Model Number | CHX-L-3750KVA/65KV |
| Certification | ISO9001 |
| Place of Origin | CHINA |
MOQ: One unit
Price: 40000~150000 USD /Unit according to detailed model
| Payment Terms | L/C, T/T |
| Supply Ability | 5units/2months |
| Delivery Time | 35~45 work days |
| Packaging Details | Export standard wooden case with fumigation free |
| Test Principle | Power Frequency Resonant Circuit |
| Usage | AC Hipot Test for large generator stator or rotor winding |
| Max.capacity: | 3750KVA |
| Max. Voltage | 65KV |
| Design Feature: | Adjustable inductance test reactor , 50Hz or 60Hz testing ,Dedicated to large hydroelectric generator stator test |
| Component | Control console,Voltage regulator,Excitation Transformer,Adjustable inductance reactor, Optional load compensation load reactor, And Voltage Divider |
| Test Frequency | 50Hz or 60Hz |
| Duty Cycle | 10mints or made by order |
| Test Accuracy | No Less Than 1.0% |
| Output Waveform | Pure Sine Wave |
| Special For | AC Hipot test for Large hydro-generator stator or thermal generator stator |
| Test Standard: | IEC60060-1:2010 ; IEC 60034-1:2004; IEEE 115:2009; GB/T 8564-2003; JB/T 6204-2002 |
| Note | PD free Type can be made by order |
| Brand Name | Fanke High-voltage |
| Model Number | CHX-L-3750KVA/65KV |
| Certification | ISO9001 |
| Place of Origin | CHINA |
MOQ: One Set
Price: Negotiable
| Payment Terms | L/C, T/T |
| Supply Ability | 20 sets / month |
| Delivery Time | 20~30 working days |
| Packaging Details | Export standard wooden case with fumigation free |
| Test Principle: | Very-low frequency technology principle |
| Usage | 0.1Hz Withstand Voltage test for 45KV and below MV power cable and generator |
| Design Feature | Two HV boosters, 40KV/50KV for single one |
| Component | Controller,HV booster,Compensation capacitor Load |
| Test Frequency | 0.1Hz, 0.05Hz, 0.02Hz |
| Max.Test Voltage | 0~ 90KV(peak), continuously adjustable |
| Load Range: | 0.1Hz, ≤0.5μF ; 0.05HZ,≤0.1μF ;0.02HZ ≤2.5μF |
| Test Accuracy | No Less Than 3% |
| Output Waveform | Good Sine Wave,Voltage, Waveform distortion ≤ 5% |
| HV Booster Using Way | Single or In Series Connection |
| Duty Cycle | 60mints |
| Brand Name | Fanke High-voltage |
| Model Number | VLF-90KV/0.1Hz |
| Certification | ISO9001 |
| Place of Origin | China |
MOQ: One Set
Price: Negotiable
| Payment Terms | L/C, T/T |
| Supply Ability | 20 sets / month |
| Delivery Time | 20~30 working days |
| Packaging Details | Export standard wooden case with fumigation free |
| Test Principle: | Very-low frequency technology principle |
| Usage | 0.1Hz Withstand Voltage test for 45KV and below MV power cable and generator |
| Design Feature | Two HV boosters, 40KV/50KV for single one |
| Component | Controller,HV booster,Compensation capacitor Load |
| Test Frequency | 0.1Hz, 0.05Hz, 0.02Hz |
| Max.Test Voltage | 0~ 90KV(peak), continuously adjustable |
| Load Range: | 0.1Hz, ≤0.5μF ; 0.05HZ,≤0.1μF ;0.02HZ ≤2.5μF |
| Test Accuracy | No Less Than 3% |
| Output Waveform | Good Sine Wave,Voltage, Waveform distortion ≤ 5% |
| HV Booster Using Way | Single or In Series Connection |
| Duty Cycle | 60mints |
| Brand Name | Fanke High-voltage |
| Model Number | VLF-90KV/0.1Hz |
| Certification | ISO9001 |
| Place of Origin | China |
MOQ: One Set
Price: Negotiable
| Payment Terms | L/C, T/T |
| Supply Ability | 20 sets / month |
| Delivery Time | 20~30 working days |
| Packaging Details | Export standard wooden case with fumigation free |
| Test Principle: | Very-low frequency technology principle |
| Usage | 0.1Hz Withstand Voltage test for 35KV and below MV power cable and generator |
| Design Feature | Two HV boosters, 30KV/50KV for single one |
| Component | Controller,HV booster,Compensation capacitor Load |
| Test Frequency | 0.1Hz, 0.05Hz, 0.02Hz |
| Max.Test Voltage | 0~ 80KV(peak), continuously adjustable |
| Load Range: | 0.1Hz, ≤0.5μF ; 0.05HZ,≤0.1μF ;0.02HZ ≤2.5μF |
| Test Accuracy | No Less Than 3% |
| Output Waveform | Good Sine Wave,Voltage, Waveform distortion ≤ 5% |
| HV Booster Using Way | Single or In Series Connection |
| Duty Cycle | 60mints |
| Brand Name | Fanke High-voltage |
| Model Number | VLF-80KV/0.1Hz |
| Certification | ISO9001 |
| Place of Origin | China |
MOQ: One Set
Price: Negotiable
| Payment Terms | L/C, T/T |
| Supply Ability | 20 sets / month |
| Delivery Time | 20~30 working days |
| Packaging Details | Export standard wooden case with fumigation free |
| Test Principle: | Very-low frequency technology principle |
| Usage | 0.1Hz Withstand Voltage test for 35KV and below MV power cable and generator |
| Design Feature | Two HV boosters, 30KV/50KV for single one |
| Component | Controller,HV booster,Compensation capacitor Load |
| Test Frequency | 0.1Hz, 0.05Hz, 0.02Hz |
| Max.Test Voltage | 0~ 80KV(peak), continuously adjustable |
| Load Range: | 0.1Hz, ≤0.5μF ; 0.05HZ,≤0.1μF ;0.02HZ ≤2.5μF |
| Test Accuracy | No Less Than 3% |
| Output Waveform | Good Sine Wave,Voltage, Waveform distortion ≤ 5% |
| HV Booster Using Way | Single or In Series Connection |
| Duty Cycle | 60mints |
| Brand Name | Fanke High-voltage |
| Model Number | VLF-80KV/0.1Hz |
| Certification | ISO9001 |
| Place of Origin | China |
MOQ: One Set
Price: Negotiable
| Payment Terms | T/T |
| Supply Ability | 20 sets / month |
| Delivery Time | 10-15working days |
| Packaging Details | Export standard wooden case with fumigation free |
| Test object | Cable Tesing and Generator Testing |
| Test Item | AC Withstand Voltage Test |
| Test Freq. | 0.1Hz, 0.05Hz, 0.02Hz |
| Component | Controller,HV booster,Compensation capacitor Load |
| Test Voltage | 0~ 60KV |
| Accuracy | ± (3% of full scale +0.5 KV) |
| Working Time | 60mints |
| Brand Name | Fanke High-voltage |
| Model Number | VLF-60KV/0.1Hz |
| Certification | ISO9001 |
| Place of Origin | China |
MOQ: One Set
Price: Negotiable
| Payment Terms | T/T |
| Supply Ability | 20 sets / month |
| Delivery Time | 10-15working days |
| Packaging Details | Export standard wooden case with fumigation free |
| Test object | Cable Tesing and Generator Testing |
| Test Item | AC Withstand Voltage Test |
| Test Freq. | 0.1Hz, 0.05Hz, 0.02Hz |
| Component | Controller,HV booster,Compensation capacitor Load |
| Test Voltage | 0~ 60KV |
| Accuracy | ± (3% of full scale +0.5 KV) |
| Working Time | 60mints |
| Brand Name | Fanke High-voltage |
| Model Number | VLF-60KV/0.1Hz |
| Certification | ISO9001 |
| Place of Origin | China |
MOQ: One Set
Price: Negotiable
| Payment Terms | T/T |
| Supply Ability | 20 sets / month |
| Delivery Time | 10-15working days |
| Packaging Details | Export standard wooden case with fumigation free |
| Test object | Cable Tesing and Generator Testing |
| Test Item | AC Withstand Voltage Test |
| Test Freq. | 0.1Hz, 0.05Hz, 0.02Hz |
| Component | Controller,HV booster,Compensation capacitor Load |
| Test Voltage | 0~ 50KV |
| Accuracy | ± (3% of full scale +0.5 KV) |
| Working Time | 60mints |
| Brand Name | Fanke High-voltage |
| Model Number | VLF-50KV/0.1Hz |
| Certification | ISO9001 |
| Place of Origin | China |
MOQ: One Set
Price: Negotiable
| Payment Terms | T/T |
| Supply Ability | 20 sets / month |
| Delivery Time | 10-15working days |
| Packaging Details | Export standard wooden case with fumigation free |
| Test object | Cable Tesing and Generator Testing |
| Test Item | AC Withstand Voltage Test |
| Test Freq. | 0.1Hz, 0.05Hz, 0.02Hz |
| Component | Controller,HV booster,Compensation capacitor Load |
| Test Voltage | 0~ 50KV |
| Accuracy | ± (3% of full scale +0.5 KV) |
| Working Time | 60mints |
| Brand Name | Fanke High-voltage |
| Model Number | VLF-50KV/0.1Hz |
| Certification | ISO9001 |
| Place of Origin | China |
Explore more categories
Get in touch with us
Leave a Message, we will call you back quickly!