Products
Manufacturer of a wide range of products which include Variable Frequency AC Resonant Test System , High Voltage Test Set For UHV Substation Or GIS,Variable Frequency AC Resonant Test System , High Voltage Test Set For UHV Substat...
MOQ: One Set
Price: Negotiable
| Payment Terms | L/C, T/T |
| Supply Ability | 5 sets / 2months |
| Delivery Time | 45~60 working days |
| Packaging Details | Export standard wooden case with fumigation free |
| Test Principle | Variable Frequency Resonant Circuit |
| Usage | On-site AC Withstand Voltage Test |
| Design Feature: | Highed Voltage Modular Test Reactor, Higher Q Value Output ,Multiple Test Range |
| Component: | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider |
| Test Frequency: | 30-300Hz |
| Duty Cycle | 15mints or 60 Mints |
| Test Accuracy | No Less Than 1.5% |
| Output Waveform | Good Sine Wave |
| Special For | On-site Test For UHV GIS , GIL , CT, PT |
| Test Standard: | IEC60060-1:2010;IEC 62271-203:2011 for GIS |
| Brand Name | Fanke |
| Model Number | CHX-4800KVA/200KV,400KV,600KV,800KV |
| Certification | ISO9001 |
| Place of Origin | CHINA |
MOQ: One Set
Price: Negotiable
| Payment Terms | L/C, T/T |
| Supply Ability | 5 sets / 2months |
| Delivery Time | 45~60 working days |
| Packaging Details | Export standard wooden case with fumigation free |
| Test Principle | Variable Frequency Resonant Circuit |
| Usage | On-site AC Withstand Voltage Test |
| Design Feature: | Highed Voltage Modular Test Reactor, Higher Q Value Output ,Multiple Test Range |
| Component: | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider |
| Test Frequency: | 30-300Hz |
| Duty Cycle | 15mints or 60 Mints |
| Test Accuracy | No Less Than 1.5% |
| Output Waveform | Good Sine Wave |
| Special For | On-site Test For UHV GIS , GIL , CT, PT |
| Test Standard: | IEC60060-1:2010;IEC 62271-203:2011 for GIS |
| Brand Name | Fanke |
| Model Number | CHX-4800KVA/200KV,400KV,600KV,800KV |
| Certification | ISO9001 |
| Place of Origin | CHINA |
MOQ: One unit
Price: Negotiable
| Payment Terms | T/T |
| Supply Ability | 4units/2months |
| Delivery Time | 45-65 work days |
| Packaging Details | Export Standard Wooden Case With Fumigation Free |
| Usage | Measurement and control unit for Power Frequency AC resonant withstand voltage test circuit. |
| Advantage | best protections and best monitoring functions |
| Operation way | Double control way , PLC computer control or manual button control |
| Speical for | Replace the old traditional console to increase the efficiency |
| Max.Control voltage | no limit, made by order |
| Max.Control current | no limit, made by order |
| Test Accuracy | No Less Than 1.5% |
| Power supply | 380V, 50/60Hz, Single phase |
| Brand Name | Fanke High-voltage |
| Model Number | CHX-(L) Series |
| Certification | ISO9001 |
| Place of Origin | CHINA |
MOQ: One unit
Price: Negotiable
| Payment Terms | T/T |
| Supply Ability | 4units/2months |
| Delivery Time | 45-65 work days |
| Packaging Details | Export Standard Wooden Case With Fumigation Free |
| Usage | Measurement and control unit for Power Frequency AC resonant withstand voltage test circuit. |
| Advantage | best protections and best monitoring functions |
| Operation way | Double control way , PLC computer control or manual button control |
| Speical for | Replace the old traditional console to increase the efficiency |
| Max.Control voltage | no limit, made by order |
| Max.Control current | no limit, made by order |
| Test Accuracy | No Less Than 1.5% |
| Power supply | 380V, 50/60Hz, Single phase |
| Brand Name | Fanke High-voltage |
| Model Number | CHX-(L) Series |
| Certification | ISO9001 |
| Place of Origin | CHINA |
MOQ: One unit
Price: Negotiable
| Payment Terms | L/C, T/T |
| Supply Ability | 2units/3months |
| Delivery Time | 65~90 work days |
| Packaging Details | Export Standard Wooden Case With Fumigation Free |
| Usage | EHV CVT and CB Rutine Testing |
| Test Item | AC Hipot Test And Partial Discharge Test |
| Test Voltage | No More Than 800KV |
| Test Current | No More Than 5A |
| Test Frequency | 50Hz or 60Hz |
| PD Free | No More Than 10pC At 800KV |
| Duty Cycle | 30mints or made by order |
| Test Accuracy | No Less Than 1.0% |
| Brand Name | Fanke High-voltage |
| Model Number | CHX-(L) Series |
| Certification | ISO9001 |
| Place of Origin | CHINA |
MOQ: One unit
Price: Negotiable
| Payment Terms | L/C, T/T |
| Supply Ability | 2units/3months |
| Delivery Time | 65~90 work days |
| Packaging Details | Export Standard Wooden Case With Fumigation Free |
| Usage | EHV CVT and CB Rutine Testing |
| Test Item | AC Hipot Test And Partial Discharge Test |
| Test Voltage | No More Than 800KV |
| Test Current | No More Than 5A |
| Test Frequency | 50Hz or 60Hz |
| PD Free | No More Than 10pC At 800KV |
| Duty Cycle | 30mints or made by order |
| Test Accuracy | No Less Than 1.0% |
| Brand Name | Fanke High-voltage |
| Model Number | CHX-(L) Series |
| Certification | ISO9001 |
| Place of Origin | CHINA |
MOQ: One Set
Price: Negotiable
| Payment Terms | L/C, T/T |
| Supply Ability | 5 sets / 2months |
| Delivery Time | 45~60 working days |
| Packaging Details | Export standard wooden case with fumigation free |
| Test Principle | Variable Frequency Resonant Circuit |
| Usage | On-site AC Withstand Voltage Test Under 200KV,400KV,600KV, 800KV For HV GIS or GIL |
| Design Feature: | Highed Voltage Modular Test Reactor, Higher Q Value Output ,Multiple Test Range |
| Component: | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider |
| Test Frequency: | 30-300Hz |
| Duty Cycle | 15mints or 60 Mints |
| Test Accuracy | No Less Than 1.5% |
| Output Waveform | Good Sine Wave |
| Special For | On-site Test For HV or EHV GIS ,CT,PT |
| Reactor Using Way | In Series Or In Parallel Connection |
| Test Standard: | IEC60060-1:2010;IEC 62271-203:2011 for GIS |
| Brand Name | Fanke |
| Model Number | CHX-4800KVA/200KV,400KV,600KV,800KV |
| Certification | ISO9001 |
| Place of Origin | CHINA |
MOQ: One Set
Price: Negotiable
| Payment Terms | L/C, T/T |
| Supply Ability | 5 sets / 2months |
| Delivery Time | 45~60 working days |
| Packaging Details | Export standard wooden case with fumigation free |
| Test Principle | Variable Frequency Resonant Circuit |
| Usage | On-site AC Withstand Voltage Test Under 200KV,400KV,600KV, 800KV For HV GIS or GIL |
| Design Feature: | Highed Voltage Modular Test Reactor, Higher Q Value Output ,Multiple Test Range |
| Component: | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider |
| Test Frequency: | 30-300Hz |
| Duty Cycle | 15mints or 60 Mints |
| Test Accuracy | No Less Than 1.5% |
| Output Waveform | Good Sine Wave |
| Special For | On-site Test For HV or EHV GIS ,CT,PT |
| Reactor Using Way | In Series Or In Parallel Connection |
| Test Standard: | IEC60060-1:2010;IEC 62271-203:2011 for GIS |
| Brand Name | Fanke |
| Model Number | CHX-4800KVA/200KV,400KV,600KV,800KV |
| Certification | ISO9001 |
| Place of Origin | CHINA |
MOQ: One Unit
Price: Negotiable
| Payment Terms | L/C, T/T |
| Supply Ability | 10sets / 2months |
| Delivery Time | 25~35 Working Days |
| Packaging Details | Export Standard Wooden Case With Fumigation Free |
| Test Principle | Variable Frequency Resonant Circuit |
| Usage | AC Withstand Voltage Test for HV cable or GIS |
| MAX.Capacity | 3000KVA or OEM |
| Max.Voltage | 150KV or OEM |
| Test Frequency | 20-300Hz |
| Duty Cycle | 60 mints or OEM |
| Test Accuracy | No less than 1.5% |
| Special For | On-site Test For long HV XLPE cable and GIS |
| Test Standard | IEC 60060-1:2010;IEC 60840:2011 and IEC 62067:2011 for XLPE cable |
| Brand Name | Fanke High-voltage |
| Model Number | CHX-3000KVA/150KV |
| Certification | ISO9001 |
| Place of Origin | Wuhan ,China |
MOQ: One Unit
Price: Negotiable
| Payment Terms | L/C, T/T |
| Supply Ability | 10sets / 2months |
| Delivery Time | 25~35 Working Days |
| Packaging Details | Export Standard Wooden Case With Fumigation Free |
| Test Principle | Variable Frequency Resonant Circuit |
| Usage | AC Withstand Voltage Test for HV cable or GIS |
| MAX.Capacity | 3000KVA or OEM |
| Max.Voltage | 150KV or OEM |
| Test Frequency | 20-300Hz |
| Duty Cycle | 60 mints or OEM |
| Test Accuracy | No less than 1.5% |
| Special For | On-site Test For long HV XLPE cable and GIS |
| Test Standard | IEC 60060-1:2010;IEC 60840:2011 and IEC 62067:2011 for XLPE cable |
| Brand Name | Fanke High-voltage |
| Model Number | CHX-3000KVA/150KV |
| Certification | ISO9001 |
| Place of Origin | Wuhan ,China |