Products
Manufacturer of a wide range of products which include Large Power Generator Test Equipment Power Frequency Resonant Circuit Test,Large Power Generator Test Equipment Power Frequency Resonant Circuit Test,Automatic Insulation Resi...
MOQ: One unit
Price: 40000~150000 USD /Unit according to detailed model
| Payment Terms | L/C, T/T |
| Supply Ability | 5units/2months |
| Delivery Time | 35~45 work days |
| Packaging Details | Export standard wooden case with fumigation free |
| Test Principle | Power Frequency Resonant Circuit |
| Usage | AC Hipot Test for large generator stator or rotor winding |
| Max.capacity: | 3750KVA |
| Max. Voltage | 65KV |
| Design Feature: | Adjustable inductance test reactor , 50Hz or 60Hz testing ,Dedicated to large hydroelectric generator stator test |
| Component | Control console,Voltage regulator,Excitation Transformer,Adjustable inductance reactor, Optional load compensation load reactor, And Voltage Divider |
| Test Frequency | 50Hz or 60Hz |
| Duty Cycle | 10mints or made by order |
| Test Accuracy | No Less Than 1.0% |
| Output Waveform | Pure Sine Wave |
| Special For | AC Hipot test for Large hydro-generator stator or thermal generator stator |
| Test Standard: | IEC60060-1:2010 ; IEC 60034-1:2004; IEEE 115:2009; GB/T 8564-2003; JB/T 6204-2002 |
| Note | PD free Type can be made by order |
| Brand Name | Fanke High-voltage |
| Model Number | CHX-L-3750KVA/65KV |
| Certification | ISO9001 |
| Place of Origin | CHINA |
MOQ: One unit
Price: 40000~150000 USD /Unit according to detailed model
| Payment Terms | L/C, T/T |
| Supply Ability | 5units/2months |
| Delivery Time | 35~45 work days |
| Packaging Details | Export standard wooden case with fumigation free |
| Test Principle | Power Frequency Resonant Circuit |
| Usage | AC Hipot Test for large generator stator or rotor winding |
| Max.capacity: | 3750KVA |
| Max. Voltage | 65KV |
| Design Feature: | Adjustable inductance test reactor , 50Hz or 60Hz testing ,Dedicated to large hydroelectric generator stator test |
| Component | Control console,Voltage regulator,Excitation Transformer,Adjustable inductance reactor, Optional load compensation load reactor, And Voltage Divider |
| Test Frequency | 50Hz or 60Hz |
| Duty Cycle | 10mints or made by order |
| Test Accuracy | No Less Than 1.0% |
| Output Waveform | Pure Sine Wave |
| Special For | AC Hipot test for Large hydro-generator stator or thermal generator stator |
| Test Standard: | IEC60060-1:2010 ; IEC 60034-1:2004; IEEE 115:2009; GB/T 8564-2003; JB/T 6204-2002 |
| Note | PD free Type can be made by order |
| Brand Name | Fanke High-voltage |
| Model Number | CHX-L-3750KVA/65KV |
| Certification | ISO9001 |
| Place of Origin | CHINA |
MOQ: One unit
Price: 3000~5000 USD /Unit
| Payment Terms | L/C, T/T |
| Supply Ability | 10units/month |
| Delivery Time | 15~25 work days |
| Packaging Details | Export standard wooden case with fumigation free |
| Usage | Insulation resistance test and analyzing |
| Special for | Insulation resistance measurement for water-cooled type power generator |
| Ouput Voltage | 2500V and 5000V |
| Range | 0.1MΩ ~ 250GΩ |
| Short Circuit Current | No less than 25mA at 2500V, Max. Output upto 40mA |
| Other functions | Automatically calculates the absorption ratio and the polarization index, strong anti-interference ability, automatic discharge after test, automatic save test data |
| Brand Name | Fanke High-Voltage |
| Model Number | FKKD2678C |
| Certification | ISO9001 |
| Place of Origin | China |
MOQ: One unit
Price: 3000~5000 USD /Unit
| Payment Terms | L/C, T/T |
| Supply Ability | 10units/month |
| Delivery Time | 15~25 work days |
| Packaging Details | Export standard wooden case with fumigation free |
| Usage | Insulation resistance test and analyzing |
| Special for | Insulation resistance measurement for water-cooled type power generator |
| Ouput Voltage | 2500V and 5000V |
| Range | 0.1MΩ ~ 250GΩ |
| Short Circuit Current | No less than 25mA at 2500V, Max. Output upto 40mA |
| Other functions | Automatically calculates the absorption ratio and the polarization index, strong anti-interference ability, automatic discharge after test, automatic save test data |
| Brand Name | Fanke High-Voltage |
| Model Number | FKKD2678C |
| Certification | ISO9001 |
| Place of Origin | China |
MOQ: One unit
Price: Negotiable
| Payment Terms | T/T |
| Supply Ability | 10units/month |
| Delivery Time | 10 work days |
| Packaging Details | Export standard wooden case with fumigation free |
| Usage | Insulation resistance test and analyzing |
| Special for | Large Transformers, Generators, High-voltage Motors |
| Ouput Voltage | 1000V , 2500V , 5000V |
| Range | 0.1MΩ ~ 250GΩ |
| Short Circuit Current | No less than 3mA |
| Other functions | Automatically calculates the absorption ratio and the polarization index, strong anti-interference ability, automatic discharge after test, automatic save test data |
| Brand Name | Fanke High-Voltage |
| Model Number | UT 510-513 |
| Certification | ISO9001 |
| Place of Origin | China |
MOQ: One unit
Price: Negotiable
| Payment Terms | T/T |
| Supply Ability | 10units/month |
| Delivery Time | 10 work days |
| Packaging Details | Export standard wooden case with fumigation free |
| Usage | Insulation resistance test and analyzing |
| Special for | Large Transformers, Generators, High-voltage Motors |
| Ouput Voltage | 250V、500V、1000V、2500V、5000V、10kV |
| Range | 0.01MΩ~1000GΩ |
| Short Circuit Current | No less than 3mA |
| Special functions | PI/DAR measurements, DC /AC Voltage output for hipot test |
| Brand Name | Fanke High-Voltage |
| Model Number | UT 515A |
| Certification | ISO9001 |
| Place of Origin | China |
MOQ: One unit
Price: Negotiable
| Payment Terms | T/T |
| Supply Ability | 10units/month |
| Delivery Time | 10 work days |
| Packaging Details | Export standard wooden case with fumigation free |
| Usage | Grounding Resistance Test , Soil Resistivity Test , DC Resistance Test |
| Test method | 2/3/4-wire measurements |
| Measurement range | Ground Resistance range0.01Ω~30.00kΩ |
| Feature | With double clamp test, Large-diameter current clamp design |
| Diameter of current clamp | 50mm |
| Meet standard | IEC60101-1; IEC61010-2-31; IEC61557-1,5 |
| name | soil resistivity testing equipment |
| Brand Name | Fanke High-Voltage |
| Model Number | UT 575A |
| Certification | ISO9001 |
| Place of Origin | China |
MOQ: One unit
Price: Negotiable
| Payment Terms | T/T |
| Supply Ability | 10units/month |
| Delivery Time | 10 work days |
| Packaging Details | Export standard wooden case with fumigation free |
| Usage | Insulation resistance test and analyzing |
| Special for | Large Transformers, Generators, High-voltage Motors |
| Ouput Voltage | 1000V , 2500V , 5000V |
| Range | 0.1MΩ ~ 250GΩ |
| Short Circuit Current | No less than 3mA |
| Other functions | Automatically calculates the absorption ratio and the polarization index, strong anti-interference ability, automatic discharge after test, automatic save test data |
| Brand Name | Fanke High-Voltage |
| Model Number | UT 510-513 |
| Certification | ISO9001 |
| Place of Origin | China |
MOQ: One unit
Price: Negotiable
| Payment Terms | T/T |
| Supply Ability | 10units/month |
| Delivery Time | 10 work days |
| Packaging Details | Export standard wooden case with fumigation free |
| Usage | Insulation resistance test and analyzing |
| Special for | Large Transformers, Generators, High-voltage Motors |
| Ouput Voltage | 250V、500V、1000V、2500V、5000V、10kV |
| Range | 0.01MΩ~1000GΩ |
| Short Circuit Current | No less than 3mA |
| Special functions | PI/DAR measurements, DC /AC Voltage output for hipot test |
| Brand Name | Fanke High-Voltage |
| Model Number | UT 515A |
| Certification | ISO9001 |
| Place of Origin | China |
MOQ: One unit
Price: Negotiable
| Payment Terms | T/T |
| Supply Ability | 10units/month |
| Delivery Time | 10 work days |
| Packaging Details | Export standard wooden case with fumigation free |
| Usage | Grounding Resistance Test , Soil Resistivity Test , DC Resistance Test |
| Test method | 2/3/4-wire measurements |
| Measurement range | Ground Resistance range0.01Ω~30.00kΩ |
| Feature | With double clamp test, Large-diameter current clamp design |
| Diameter of current clamp | 50mm |
| Meet standard | IEC60101-1; IEC61010-2-31; IEC61557-1,5 |
| name | soil resistivity testing equipment |
| Brand Name | Fanke High-Voltage |
| Model Number | UT 575A |
| Certification | ISO9001 |
| Place of Origin | China |
Explore more categories