Products
Manufacturer of a wide range of products which include Variable Frequency AC Resonant Test System , High Voltage Test Set For UHV Substation Or GIS,90KV Very Low Frequency VLF High Voltage Testing Set For Cable And Generator,90KV ...
MOQ: One Set
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 5 sets / 2months |
Delivery Time | 45~60 working days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Variable Frequency Resonant Circuit |
Usage | On-site AC Withstand Voltage Test |
Design Feature: | Highed Voltage Modular Test Reactor, Higher Q Value Output ,Multiple Test Range |
Component: | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider |
Test Frequency: | 30-300Hz |
Duty Cycle | 15mints or 60 Mints |
Test Accuracy | No Less Than 1.5% |
Output Waveform | Good Sine Wave |
Special For | On-site Test For UHV GIS , GIL , CT, PT |
Test Standard: | IEC60060-1:2010;IEC 62271-203:2011 for GIS |
Brand Name | Fanke |
Model Number | CHX-4800KVA/200KV,400KV,600KV,800KV |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One Set
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 20 sets / month |
Delivery Time | 20~30 working days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle: | Very-low frequency technology principle |
Usage | 0.1Hz Withstand Voltage test for 45KV and below MV power cable and generator |
Design Feature | Two HV boosters, 40KV/50KV for single one |
Component | Controller,HV booster,Compensation capacitor Load |
Test Frequency | 0.1Hz, 0.05Hz, 0.02Hz |
Max.Test Voltage | 0~ 90KV(peak), continuously adjustable |
Load Range: | 0.1Hz, ≤0.5μF ; 0.05HZ,≤0.1μF ;0.02HZ ≤2.5μF |
Test Accuracy | No Less Than 3% |
Output Waveform | Good Sine Wave,Voltage, Waveform distortion ≤ 5% |
HV Booster Using Way | Single or In Series Connection |
Duty Cycle | 60mints |
Brand Name | Fanke High-voltage |
Model Number | VLF-90KV/0.1Hz |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One Set
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 20 sets / month |
Delivery Time | 20~30 working days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle: | Very-low frequency technology principle |
Usage | 0.1Hz Withstand Voltage test for 45KV and below MV power cable and generator |
Design Feature | Two HV boosters, 40KV/50KV for single one |
Component | Controller,HV booster,Compensation capacitor Load |
Test Frequency | 0.1Hz, 0.05Hz, 0.02Hz |
Max.Test Voltage | 0~ 90KV(peak), continuously adjustable |
Load Range: | 0.1Hz, ≤0.5μF ; 0.05HZ,≤0.1μF ;0.02HZ ≤2.5μF |
Test Accuracy | No Less Than 3% |
Output Waveform | Good Sine Wave,Voltage, Waveform distortion ≤ 5% |
HV Booster Using Way | Single or In Series Connection |
Duty Cycle | 60mints |
Brand Name | Fanke High-voltage |
Model Number | VLF-90KV/0.1Hz |
Certification | ISO9001 |
Place of Origin | China |
MOQ: One Set
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 5 sets / 2months |
Delivery Time | 45~60 working days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Variable Frequency Resonant Circuit |
Usage | On-site AC Withstand Voltage Test |
Design Feature: | Highed Voltage Modular Test Reactor, Higher Q Value Output ,Multiple Test Range |
Component: | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider |
Test Frequency: | 30-300Hz |
Duty Cycle | 15mints or 60 Mints |
Test Accuracy | No Less Than 1.5% |
Output Waveform | Good Sine Wave |
Special For | On-site Test For UHV GIS , GIL , CT, PT |
Test Standard: | IEC60060-1:2010;IEC 62271-203:2011 for GIS |
Brand Name | Fanke |
Model Number | CHX-4800KVA/200KV,400KV,600KV,800KV |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 4units/2months |
Delivery Time | 45-65 work days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Usage | Measurement and control unit for Power Frequency AC resonant withstand voltage test circuit. |
Advantage | best protections and best monitoring functions |
Operation way | Double control way , PLC computer control or manual button control |
Speical for | Replace the old traditional console to increase the efficiency |
Max.Control voltage | no limit, made by order |
Max.Control current | no limit, made by order |
Test Accuracy | No Less Than 1.5% |
Power supply | 380V, 50/60Hz, Single phase |
Brand Name | Fanke High-voltage |
Model Number | CHX-(L) Series |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One unit
Price: Negotiable
Payment Terms | T/T |
Supply Ability | 4units/2months |
Delivery Time | 45-65 work days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Usage | Measurement and control unit for Power Frequency AC resonant withstand voltage test circuit. |
Advantage | best protections and best monitoring functions |
Operation way | Double control way , PLC computer control or manual button control |
Speical for | Replace the old traditional console to increase the efficiency |
Max.Control voltage | no limit, made by order |
Max.Control current | no limit, made by order |
Test Accuracy | No Less Than 1.5% |
Power supply | 380V, 50/60Hz, Single phase |
Brand Name | Fanke High-voltage |
Model Number | CHX-(L) Series |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One unit
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 2units/3months |
Delivery Time | 65~90 work days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Usage | EHV CVT and CB Rutine Testing |
Test Item | AC Hipot Test And Partial Discharge Test |
Test Voltage | No More Than 800KV |
Test Current | No More Than 5A |
Test Frequency | 50Hz or 60Hz |
PD Free | No More Than 10pC At 800KV |
Duty Cycle | 30mints or made by order |
Test Accuracy | No Less Than 1.0% |
Brand Name | Fanke High-voltage |
Model Number | CHX-(L) Series |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One unit
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 2units/3months |
Delivery Time | 65~90 work days |
Packaging Details | Export Standard Wooden Case With Fumigation Free |
Usage | EHV CVT and CB Rutine Testing |
Test Item | AC Hipot Test And Partial Discharge Test |
Test Voltage | No More Than 800KV |
Test Current | No More Than 5A |
Test Frequency | 50Hz or 60Hz |
PD Free | No More Than 10pC At 800KV |
Duty Cycle | 30mints or made by order |
Test Accuracy | No Less Than 1.0% |
Brand Name | Fanke High-voltage |
Model Number | CHX-(L) Series |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One Set
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 5 sets / 2months |
Delivery Time | 45~60 working days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Variable Frequency Resonant Circuit |
Usage | On-site AC Withstand Voltage Test Under 200KV,400KV,600KV, 800KV For HV GIS or GIL |
Design Feature: | Highed Voltage Modular Test Reactor, Higher Q Value Output ,Multiple Test Range |
Component: | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider |
Test Frequency: | 30-300Hz |
Duty Cycle | 15mints or 60 Mints |
Test Accuracy | No Less Than 1.5% |
Output Waveform | Good Sine Wave |
Special For | On-site Test For HV or EHV GIS ,CT,PT |
Reactor Using Way | In Series Or In Parallel Connection |
Test Standard: | IEC60060-1:2010;IEC 62271-203:2011 for GIS |
Brand Name | Fanke |
Model Number | CHX-4800KVA/200KV,400KV,600KV,800KV |
Certification | ISO9001 |
Place of Origin | CHINA |
MOQ: One Set
Price: Negotiable
Payment Terms | L/C, T/T |
Supply Ability | 5 sets / 2months |
Delivery Time | 45~60 working days |
Packaging Details | Export standard wooden case with fumigation free |
Test Principle | Variable Frequency Resonant Circuit |
Usage | On-site AC Withstand Voltage Test Under 200KV,400KV,600KV, 800KV For HV GIS or GIL |
Design Feature: | Highed Voltage Modular Test Reactor, Higher Q Value Output ,Multiple Test Range |
Component: | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider |
Test Frequency: | 30-300Hz |
Duty Cycle | 15mints or 60 Mints |
Test Accuracy | No Less Than 1.5% |
Output Waveform | Good Sine Wave |
Special For | On-site Test For HV or EHV GIS ,CT,PT |
Reactor Using Way | In Series Or In Parallel Connection |
Test Standard: | IEC60060-1:2010;IEC 62271-203:2011 for GIS |
Brand Name | Fanke |
Model Number | CHX-4800KVA/200KV,400KV,600KV,800KV |
Certification | ISO9001 |
Place of Origin | CHINA |
Explore more categories